Cited by 139Neurological disorders and treatmentsObsessive-Compulsive Spectrum DisordersVagus Nerve Stimulation Research

Chronic electrocorticography for sensing movement intention and closed-loop deep brain stimulation with wearable sensors in an essential tremor patient

Open access
Herron, Jeffrey A., Thompson, Margaret C., Brown, Timothy, Chizeck, Howard J., Ojemann, Jeffrey G., Ko, Andrew L.·2017·Journal of Neurosurgery

Abstract

Deep brain stimulation (DBS) has become a widespread and valuable treatment for patients with movement disorders such as essential tremor (ET). However, current DBS treatment constantly delivers stimulation in an open loop, which can be inefficient. Closing the loop with sensors to provide feedback may increase power efficiency and reduce side effects for patients. New implantable neuromodulation platforms, such as the Medtronic Activa PC+S DBS system, offer important data sources by providing chronic neural sensing capabilities and a means of investigating dynamic stimulation based on symptom measurements. The authors implanted in a single patient with ET an Activa PC+S system, a cortical strip of electrodes on the hand sensorimotor cortex, and therapeutic electrodes in the ventral intermediate nucleus of the thalamus. In this paper they describe the effectiveness of the platform when sensing cortical movement intentions while the patient actually performed and imagined performing movements. Additionally, they demonstrate dynamic closed-loop DBS based on several wearable sensor measurements of tremor intensity.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/2016.8.jns16536

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Herron, J. A., Thompson, M. C., Brown, T., Chizeck, H. J., Ojemann, J. G., & Ko, A. L.
Affiliations
U.S. National Science Foundation (US)
Venue
Journal of Neurosurgery
Published
2017-09
Volume
127
Issue
3
Pages
580-587
ISSN
  • 0022-3085 (ISSN-L)
  • 1933-0693
OpenAlex
W2556228493
Cited by
139
References
14
Citations by year
2026: 5 · 2025: 10 · 2024: 12 · 2023: 17 · 2022: 13 · 2021: 22 · 2020: 22 · 2019: 13 · 2018: 17 · 2017: 8
FWCI
9.52
Type
journal article
Language
en
Open access
Locations
  • Journal of neurosurgery (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Science Foundation (EEC-1 028725, 1028725)
  • U.S. Department of Defense
  • National Defense Science and Engineering Graduate
Topics
  • Health Sciences › Medicine › Neurology › Neurological disorders and treatments
  • Social Sciences › Psychology › Clinical Psychology › Obsessive-Compulsive Spectrum Disorders
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
Keywords
essential tremor, deep brain stimulation, closed-loop stimulation, wearable sensors, ventral intermediate nucleus, movement intention
MeSH terms
Electrocorticography, Electrodes, Equipment Design, Humans, Male, Middle Aged, Movement, Essential Tremor, Intention, Deep Brain Stimulation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.