CoChat

Real-time imaging of convection-enhanced delivery of viruses and virus-sized particles

Szerlip, Nicholas J., Walbridge, Stuart, Yang, Linda, Morrison, Paul F., Degen, Jeffrey W., Jarrell, S. Taylor, Kouri, Joshua, Kerr, P. Benjamin, Kotin, Robert, Oldfield, Edward H., Lonser, Russell R. · 2007 · Journal of Neurosurgery
Cited by 107

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Object: Despite recent evidence showing that convection-enhanced delivery (CED) of viruses and virus-sized particles to the central nervous system (CNS) is possible, little is known about the factors influencing distribution of these vectors with convection. To better define the delivery of viruses and virus-sized particles in the CNS, and to determine optimal parameters for infusion, the authors coinfused adeno-associated virus ([AAV], 24-nm diameter) and/or feru-moxtran-10 (24 nm) by using CED during real-time magnetic resonance (MR) imaging. Methods: Sixteen rats underwent intrastriatal convective coinfusion with 4 μl of 35 S-AAV capsids (0.5–1.0 × 10 14 viral particles/ml) and increasing concentrations (0.1, 0.5, 1, and 5 mg/ml) of a similar sized iron oxide MR imaging agent (ferumoxtran-10). Five nonhuman primates underwent either convective coinfusion of 35 S-AAV capsids and 1 mg/ml ferumoxtran-10 (striatum, one animal) or infusion of 1 mg/ml ferumoxtran-10 alone (striatum in two animals; frontal white matter in two). Clinical effects, MR imaging studies, quantitative autoradiography, and histological data were analyzed. Results: Real-time, T2-weighted MR imaging of ferumoxtran-10 during infusion revealed a clearly defined hypo-intense region of perfusion. Quantitative autoradiography confirmed that MR imaging of ferumoxtran-10 at a concentration of 1 mg/ml accurately tracked viral capsid distribution in the rat and primate brain (the mean difference in volume of distribution [Vd] was 7 and 15% in rats and primates, respectively). The Vd increased linearly with increasing volume of infusion (Vi) (R 2 = 0.98). The mean Vd/Vi ratio was 4.1 ± 0.2 (mean ± standard error of the mean) in gray and 2.3 ± 0.1 in white matter (p < 0.01). The distribution of infusate was homogeneous. Postinfusion MR imaging revealed leakback along the cannula track at infusion rates greater than 1.5 μl/minute in primate gray and white matter. No animal had clinical or histological evidence of toxicity. Conclusions: The CED method can be used to deliver AAV capsids and similar sized particles to the CNS safely and effectively over clinically relevant volumes. Moreover, real-time MR imaging of ferumoxtran-10 during infusion reveals that AAV capsids and similar sized particles have different convective delivery properties than smaller proteins and other compounds.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/jns-07/09/0560

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 107

Metadata

Authors
Szerlip, N. J., Walbridge, S., Yang, L., Morrison, P. F., Degen, J. W., Jarrell, S. T., Kouri, J., Kerr, P. B., Kotin, R., Oldfield, E. H., & Lonser, R. R.
Venue
Journal of Neurosurgery
Published
2007-09
Volume
107
Issue
3
Pages
560-567
ISSN
0022-3085 (ISSN-L)
OpenAlex
W2027775485
Cited by
107
References
3
FWCI
3.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-time imaging of convection-enhanced delivery of viruses and virus-sized particles. https://app.cochat.ai/papers/10.3171/jns-07/09/0560
The paper
Szerlip, N. J., Walbridge, S., Yang, L., Morrison, P. F., Degen, J. W., Jarrell, S. T., Kouri, J., Kerr, P. B., Kotin, R., Oldfield, E. H., & Lonser, R. R. (2007). Real-time imaging of convection-enhanced delivery of viruses and virus-sized particles. Journal of Neurosurgery. https://doi.org/10.3171/jns-07/09/0560

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.