Use of a Radio Transmitter Receiver Unit for the Treatment of Neurogenic Bladder: A Preliminary Report
The DOI matches its Crossref record.
Abstract
U RINARY sepsis, secondaryto neurogenic vesical dysfunction associated with t rauma of the spinal cord, is a well recognized clinical problem. Prolonged use of indwelling catheters in paraplegic patients produces significant bacteriuria, 6 cystitis, vesicular calculi and pyelonephritis. 1 Kass and Sossen 5 have shown that use of an indwelling catheter for 24 hours results in bacteriuria in 50 per cent of patients, and in 98-100 per cent of patients after 4 days. With antibiotic therapy and closer attention to rehabilitation of the bladder during and after World War II, mortal i ty rate in paraplegics from urinary sepsis has declined. However, of approximately 746 veterans with spinal-cord injury who died during the period of 9 years following World War II , death was at t r ibuted to urinary-tract infection in 64 per cent. 6 In another series of patients urinary-tract damage was found in 65 per cent dying from other causes. 1 R uc h J in a review of the physiology of micturition, described bladder tonus or the response of smooth muscle of the bladder to the stretch imposed by filling (shown in the slowly ascending limb of a cystometrogram) as an intrinsic property of smooth muscle and not reflex in nature. Changes in this phase of the cystometrogram are shown to follow physical alterations in the tissue of the bladder. Regular, complete evacuation of the neurogenic bladder with avoidance of infec-
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Geddes, L. A., & Baker, L. E. (1967) · Medical & Biological Engineering · doi:10.1007/bf02474537 · Cited by 1,610
Sacral anterior root stimulators for bladder control in paraplegia
Brindley, G. S., Polkey, C. E., & Rushton, D. N. (1982) · Spinal Cord · doi:10.1038/sc.1982.65 · Cited by 311
An implant to empty the bladder or close the urethra.
Brindley, G. S. (1977) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.40.4.358 · Cited by 177
THE USE OF ELECTRICAL DEVICES FOR THE TREATMENT OF BLADDER DYSFUNCTION: A REVIEW OF METHODS
van BALKEN, M. R., VERGUNST, H., & BEMELMANS, B. L. H. (2004) · Journal of Urology · doi:10.1097/01.ju.0000134418.21959.98 · Cited by 121
Control of urinary bladder function with devices: successes and failures
Gaunt, R. A., & Prochazka, A. (2006) · Progress in Brain Research · doi:10.1016/s0079-6123(05)52011-9 · Cited by 105
Metadata
- Authors
- Bradley, W. E., Wittmers, L. E., Chou, S. N., & French, L. A.
- Venue
- Journal of Neurosurgery
- Published
- 1962-09
- Volume
- 19
- Issue
- 9
- Pages
- 782-786
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W1535381751
- Cited by
- 52
- References
- 0
- FWCI
- 12.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of a Radio Transmitter Receiver Unit for the Treatment of Neurogenic Bladder: A Preliminary Report. https://app.cochat.ai/papers/10.3171/jns.1962.19.9.0782
- The paper
- Bradley, W. E., Wittmers, L. E., Chou, S. N., & French, L. A. (1962). Use of a Radio Transmitter Receiver Unit for the Treatment of Neurogenic Bladder: A Preliminary Report. Journal of Neurosurgery. https://doi.org/10.3171/jns.1962.19.9.0782
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.