The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Assessment of intracranial hemodynamics in carotid artery disease by transcranial Doppler ultrasound
Abstract
✓ Noninvasive transcranial Doppler recordings were correlated to the angiographic findings in 77 patients with carotid artery disease. Stenoses reducing the luminal area of the internal carotid artery by 75% or more also reduced the pulsatility transmission index (PTI) of the ipsilateral middle cerebral artery (MCA). The PTI is the pulsatility index of the artery under study expressed as a percent of the pulsatility index of another intracranial artery with presumed unimpeded inflow in the same individual. For stenoses in the 75% to 89% category, PTI reduction was significantly greater in patients with bilateral carotid stenosis, indicating an impaired potential for collateral flow in these patients. The PTI reduction probably reflects both the pressure drop across the stenosis and the cerebral autoregulatory response. Two criteria proved useful in demonstrating collateral MCA supply through the circle of Willis. On the recipient side, retrograde flow in the proximal anterior cerebral artery was demonstrated in 29 of the 31 patients when this flow pattern was disclosed angiographically. In 26 of these patients, the anterior cerebral artery on the supplying side also had clearly increased flow velocity. Increased flow velocities in the proximal posterior cerebral artery were present in 26 of the 30 vessels that were acting as a collateral channel to the ipsilateral MCA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries
Aaslid, R., Markwalder, T.-M., & Nornes, H. (1982) · Journal of Neurosurgery · doi:10.3171/jns.1982.57.6.0769 · Cited by 3,046
Self-citationProblems of Spectrum and Bias in Evaluating the Efficacy of Diagnostic Tests
Ransohoff, D. F., & Feinstein, A. R. (1978) · New England Journal of Medicine · doi:10.1056/nejm197810262991705 · Cited by 1,734
Evaluation of cerebrovascular spasm with transcranial Doppler ultrasound
Aaslid, R., Huber, P., & Nornes, H. (1984) · Journal of Neurosurgery · doi:10.3171/jns.1984.60.1.0037 · Cited by 681
Self-citationHass, W. K. (1968) · JAMA · doi:10.1001/jama.203.11.961 · Cited by 540
Markwalder, T.-M., Grolimund, P., Seiler, R. W., Roth, F., & Aaslid, R. (1984) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1984.54 · Cited by 463
Self-citationPulsed Ultrasonic Doppler Blood-Flow Sensing
Baker, D. W. (1970) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1970.29558 · Cited by 371
Hass, W. K. (1968) · JAMA · doi:10.1001/jama.1968.03140110053011 · Cited by 364
Quantitation of carotid stenosis with continuous-wave (C-W) Doppler ultrasound.
Spencer, M. P., & Reid, J. M. (1979) · Stroke · doi:10.1161/01.str.10.3.326 · Cited by 355
Normal Size of the Internal Carotid, Middle Cerebral and Anterior Cerebral Arteries
Gabrielsen, T. O., & Greitz, T. V. B. (1970) · Acta Radiologica Diagnosis · doi:10.1177/028418517001000101 · Cited by 145
Evans, D., Barrie, W. W., Asher, M. J., Bentley, S., & BELL, P. R. F. (1980) · Circulation Research · doi:10.1161/01.res.46.4.470 · Cited by 104
Cited by
Cerebral vasospasm diagnosis by means of angiography and blood velocity measurements
Lindegaard, K. F., Nornes, H., Bakke, S. J., Sorteberg, W., & Nakstad, P. (1989) · Acta Neurochirurgica · doi:10.1007/bf01405268 · Cited by 495
Self-citationThe pulsating brain: A review of experimental and clinical studies of intracranial pulsatility
Wagshul, M. E., Eide, P. K., & Madsen, J. R. (2011) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-8-5 · Cited by 473
Lindegaard, K. F., Lundar, T., Wiberg, J., Sjøberg, D., Aaslid, R., & Nornes, H. (1987) · Stroke · doi:10.1161/01.str.18.6.1025 · Cited by 309
Self-citationAssessment of ≥50% and <50% Intracranial Stenoses by Transcranial Color-Coded Duplex Sonography
Baumgartner, R. W., Mattle, H. P., & Schroth, G. (1999) · Stroke · doi:10.1161/01.str.30.1.87 · Cited by 289
Alexandrov, A. V., Sloan, M. A., Tegeler, C. H., Newell, D. N., Lumsden, A., Garami, Z., Levy, C. R., Wong, L. K. S., Douville, C., Kaps, M., et al. (2012) · Journal of Neuroimaging · doi:10.1111/j.1552-6569.2010.00523.x · Cited by 272
Transcranial doppler sonography: Anatomical landmarks and normal velocity values
Ringelstein, E. B., Kahlscheuer, B., Niggemeyer, E., & Otis, S. M. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90039-f · Cited by 263
Hennerici, M., Rautenberg, W., Sitzer, G., & Schwartz, A. (1987) · Surgical Neurology · doi:10.1016/0090-3019(87)90251-5 · Cited by 258
Anatomy and Functionality of Leptomeningeal Anastomoses: A Review
Brozici, M., van der Zwan, A., & Hillen, B. (2003) · Stroke · doi:10.1161/01.str.0000095791.85737.65 · Cited by 249
Measurement of arterial blood flow by Doppler ultrasound
Hoskins, P. R. (1990) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/11/1/001 · Cited by 109
Metadata
- Authors
- Lindegaard, K.-F., Bakke, S. J., Grolimund, P., Aaslid, R., Huber, P., & Nornes, H.
- Venue
- Journal of Neurosurgery
- Published
- 1985-12
- Volume
- 63
- Issue
- 6
- Pages
- 890-898
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2033812224
- Cited by
- 263
- References
- 11
- FWCI
- 21.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.