Treatment of chronic pain by epidural spinal cord stimulation: a 10-year experience
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
✓ Epidural spinal cord stimulation by means of chronically implanted electrodes was carried out on 121 patients with pain of varied benign organic etiology. In 116 patients, the pain was confined to the back and lower extremities and, of these, 56 exhibited the failed-back syndrome. Most patients were referred by a pain management service because of failure of conventional pain treatment modalities. Electrodes were implanted at varying sites, dictated by the location of pain. A total of 140 epidural implants were used: 76 unipolar, 46 Resume electrodes, 12 bipolar, and six quadripolar. Patients were followed for periods ranging from 6 months to 10 years, with a mean follow-up period of 40 months. Forty-eight patients (40%) were able to control their pain by neurostimulation alone. A further 14 patients (12%), in addition to following a regular stimulation program, needed occasional analgesic supplements to achieve 50% or more relief of the prestimulation pain. Pain secondary to arachnoiditis or perineural fibrosis following multiple intervertebral disc operations, when predominantly confined to one lower extremity, seemed to respond favorably to this treatment. Uniformly good results were also obtained in lower-extremity pain secondary to multiple sclerosis. Pain due to advanced peripheral vascular disease of the lower limbs was well controlled, and amputation below the knee was delayed for up to 2 years in some patients. Pain due to cauda equina injury, paraplegic pain, phantom-limb pain, pure midline back pain without radiculopathy, or pain due to primary bone or joint disease seemed to respond less well. Patients who responded to preliminary transcutaneous electrical nerve stimulation generally did well with electrode implants. Notable complications included wound infection, electrode displacement or fracturing, and fibrosis at the stimulating tip of the electrode. Three patients in this series died due to unrelated causes. Epidural spinal cord stimulation has proven to be an effective and safe means of controlling pain on a long-term basis in selected groups of patients. The mechanism of action of stimulation-produced analgesia remains unclear; further studies to elucidate it might allow spinal cord stimulation to be exploited more effectively in disorders that are currently refractory to this treatment modality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of chronic pain. I. Aspects of the reliability and validity of the visual analogue scale
Carlsson, A. M. (1983) · Pain · doi:10.1016/0304-3959(83)90088-x · Cited by 1,853
LLUSIA, J. B. (1983) · PubMed · Cited by 1,289
Temporary Abolition of Pain in Man
Wall, P. D., & Sweet, W. H. (1967) · Science · doi:10.1126/science.155.3758.108 · Cited by 969
Pain Measurement and Assessment
THOMPSON, T. L. (1984) · American Journal of Psychiatry · doi:10.1176/ajp.141.11.1478 · Cited by 555
Addleton, J. (1981) · Bulletin of Concerned Asian Scholars · doi:10.1080/14672715.1981.10409838 · Cited by 348
Dorsal Column Electroanalgesia
Shealy, C. N., Mortimer, J. T., & Hagfors, N. R. (1970) · Journal of Neurosurgery · doi:10.3171/jns.1970.32.5.0560 · Cited by 281
Stimulation of internal capsule for relief of chronic pain
Adams, J. E., Hosobuchi, Y., & Fields, H. L. (1974) · Journal of Neurosurgery · doi:10.3171/jns.1974.41.6.0740 · Cited by 245
AUGUSTINSSON, L. E., CARLSSON, C. A., HOLM, J., & JIVEGARD, L. (1985) · Annals of Surgery · doi:10.1097/00000658-198507000-00017 · Cited by 243
Spinal cord stimulation in management of chronic pain: A 9-year experience
Meglio, M., Cioni, B., & Rossi, G. F. (1989) · Journal of Neurosurgery · doi:10.3171/jns.1989.70.4.0519 · Cited by 211
Vascular disease of extremities. Electric stimulation of spinal cord and posterior roots.
Aw, C., Oygar, A., Baggenstos, P., Pacheco, S., & Klériga, E. (1976) · PubMed · Cited by 210
Cited by
North, R. B., Kidd, D. H., Farrokhi, F., & Piantadosi, S. A. (2005) · Neurosurgery · doi:10.1227/01.neu.0000144839.65524.e0 · Cited by 926
Kapural, L., Yu, C., Doust, M. W., Gliner, B. E., Vallejo, R., Sitzman, B. T., Amirdelfan, K., Morgan, D. M., Brown, L. L., Yearwood, T. L., et al. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000774 · Cited by 850
Cameron, T. (2004) · Journal of Neurosurgery: Spine · doi:10.3171/spi.2004.100.3.0254 · Cited by 799
Clinical Effectiveness and Cost-Effectiveness of Treatments for Patients With Chronic Pain
Turk, D. C. (2002) · The Clinical Journal of Pain · doi:10.1097/00002508-200211000-00003 · Cited by 643
Kumar, K., Taylor, R. S., Jacques, L., Eldabe, S., Meglio, M., Molet, J., Thomson, S., O'Callaghan, J., Eisenberg, E., Milbouw, G., et al. (2008) · Neurosurgery · doi:10.1227/01.neu.0000325731.46702.d9 · Cited by 639
Self-citationDeer, T. R., Mekhail, N., Provenzano, D., Pope, J., Krames, E., Leong, M., Levy, R. M., Abejon, D., Buchser, E., Burton, A., et al. (2014) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12208 · Cited by 596
Self-citationSpinal Cord Stimulation for Chronic, Intractable Pain
North, R. B., Kidd, D. H., Zahurak, M., James, C. S., & Long, D. M. (1993) · Neurosurgery · doi:10.1227/00006123-199303000-00008 · Cited by 496
Kumar, K., Hunter, G., & Demeria, D. (2006) · Neurosurgery · doi:10.1227/01.neu.0000192162.99567.96 · Cited by 488
Self-citationDeep Brain Stimulation for Intractable Pain: A 15-Year Experience
Kumar, K., Toth, C., & Nath, R. K. (1997) · Neurosurgery · doi:10.1097/00006123-199704000-00015 · Cited by 387
Self-citationAl-Kaisy, A., Van Buyten, J.-P., Smet, I., Palmisani, S., Pang, D., & Smith, T. (2014) · Pain Medicine · doi:10.1111/pme.12294 · Cited by 345
Burchiel, K. J., Anderson, V. C., Brown, F. D., Fessler, R. G., Friedman, W. A., Pelofsky, S., Weiner, R. L., Oakley, J., & Shatin, D. (1996) · Spine · doi:10.1097/00007632-199612010-00015 · Cited by 340
Taylor, R. S., Van Buyten, J.-P., & Buchser, E. (2005) · Spine · doi:10.1097/01.brs.0000149199.68381.fe · Cited by 337
Physiology of Spinal Cord Stimulation: Review and Update
Linderoth, B., & Foreman, R. D. (1999) · Neuromodulation: Technology at the Neural Interface · doi:10.1046/j.1525-1403.1999.00150.x · Cited by 319
Kumar, K., Toth, C., Nath, R., & Laing, P. (1998) · Surgical Neurology · doi:10.1016/s0090-3019(98)00012-3 · Cited by 309
Self-citationTaylor, R. S., Van Buyten, J., & Buchser, E. (2006) · European Journal of Pain · doi:10.1016/j.ejpain.2005.02.004 · Cited by 276
Phantom Limb Pain: Theories and Therapies
Weeks, S. R., Anderson-Barnes, V. C., & Tsao, J. W. (2010) · The Neurologist · doi:10.1097/nrl.0b013e3181edf128 · Cited by 207
Spinal cord stimulation for chronic pain
Mailis-Gagnon, A., Furlan, M. P., Sandoval, J. A., & Taylor, R. S. (2004) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003783.pub2 · Cited by 189
RetractedComplications of spinal cord stimulation, suggestions to improve outcome, and financial impact
Kumar, K., Wilson, J. R., Taylor, R. S., & Gupta, S. (2006) · Journal of Neurosurgery: Spine · doi:10.3171/spi.2006.5.3.191 · Cited by 184
Self-citationCurrent perspectives on intrathecal drug delivery
Christo, P., & Bottros, M. (2014) · Journal of Pain Research · doi:10.2147/jpr.s37591 · Cited by 174
“29–31 The risk of deep infections including epidural abscess and meningitis ranges from 0% to 0.5% in the same series.”
InfluentialImplantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126
Electrical Stimulation and Motor Recovery
Young, W. (2015) · Cell Transplantation · doi:10.3727/096368915x686904 · Cited by 76
Suitability of NFC for Medical Device Communication and Power Delivery
Freudenthal, E., Herrera, D., Kautz, F., Natividad, C., Ogrey, A., Sipla, J., Sosa, A., Betancourt, C., & Estevez, L. (2007) · 2007 IEEE Dallas Engineering in Medicine and Biology Workshop · doi:10.1109/embsw.2007.4454171 · Cited by 29
“Potential applications of implanted NFC for stimulation include: • Direct mitigation of chronic pain through the use of spinal chord stimulation (see [9], [ 4 ]), • Reduction of Parkinson’s disease symptoms through the use of deep brain stimulation (see Krausea, Fogela et al. [3]).”
Background
Metadata
- Authors
- Kumar, K., Nath, R., & Wyant, G. M.
- Venue
- Journal of Neurosurgery
- Published
- 1991-09
- Volume
- 75
- Issue
- 3
- Pages
- 402-407
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W1970735973
- Cited by
- 239
- References
- 25
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.