Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 420

The DOI matches its Crossref record.

Bilateral subthalamic stimulation for Parkinson's disease by using three-dimensional stereotactic magnetic resonance imaging and electrophysiological guidance

Bejjani, Boulos-Paul, Dormont, Didier, Pidoux, Bernard, Yelnik, Jérôme, Damier, Philippe, Arnulf, Isabelle, Bonnet, Anne-Marie, Marsault, Claude, Agid, Yves, Philippon, Jacques, Cornu, Philippe·2000·Journal of Neurosurgery

Abstract

Object. Several methods are used for stereotactically guided implantation of electrodes into the subthalamic nucleus (STN) for continuous high-frequency stimulation in the treatment of Parkinson's disease (PD). The authors present a stereotactic magnetic resonance (MR) method relying on three-dimensional (3D) T 1-weighted images for surgical planning and multiplanar T 2-weighted images for direct visualization of the STN, coupled with electrophysiological recording and stimulation guidance. Methods. Twelve patients with advanced PD were enrolled in this study of bilateral STN implantation. Both STNs were visible as 3D ovoid biconvex hypointense structures located in the upper mesencephalon. The coordinates of the centers of the STNs were determined with reference to the patient's anterior commissure—posterior commissure line by using a new landmark, the anterior border of the red nucleus. Electrophysiological monitoring through five parallel tracks was performed simultaneously to define the functional target accurately. Microelectrode recording identified high-frequency, spontaneous, movement-related activity and tremor-related cells within the STNs. Acute STN macrostimulation improved contralateral rigidity and akinesia, suppressed tremor when present, and could induce dyskinesias. The central track, which was directed at the predetermined target by using MR imaging, was selected for implantation of 19 of 24 electrodes. No surgical complications were noted. Conclusions. At evaluation 6 months after surgery, continuous STN stimulation was shown to have improved parkinsonian motor disability by 64% and 78% in the “off” and “on” medication states, respectively. Antiparkinsonian drug treatment was reduced by 70% in 10 patients and withdrawn in two patients. The severity of levodopainduced dyskinesias was reduced by 83% and motor fluctuations by 88%. Continuous high-frequency stimulation of the STN applied through electrodes implanted with the aid of 3D MR imaging and electrophysiological guidance is a safe and effective therapy for patients suffering from severe, advanced levodopa-responsive PD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/jns.2000.92.4.0615

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 420

Metadata

Authors
Bejjani, B.-P., Dormont, D., Pidoux, B., Yelnik, J., Damier, P., Arnulf, I., Bonnet, A.-M., Marsault, C., Agid, Y., Philippon, J., & Cornu, P.
Venue
Journal of Neurosurgery
Published
2000-04
Volume
92
Issue
4
Pages
615-625
ISSN
0022-3085 (ISSN-L)
OpenAlex
W1994180654
Cited by
420
References
0
FWCI
11.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bilateral subthalamic stimulation for Parkinson's disease by using three-dimensional stereotactic magnetic resonance imaging and electrophysiological guidance. https://app.cochat.ai/papers/10.3171/jns.2000.92.4.0615
The paper
Bejjani, B.-P., Dormont, D., Pidoux, B., Yelnik, J., Damier, P., Arnulf, I., Bonnet, A.-M., Marsault, C., Agid, Y., Philippon, J., & Cornu, P. (2000). Bilateral subthalamic stimulation for Parkinson's disease by using three-dimensional stereotactic magnetic resonance imaging and electrophysiological guidance. Journal of Neurosurgery. https://doi.org/10.3171/jns.2000.92.4.0615

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.