Intraorbital implantation of a stimulating electrode for an optic nerve visual prosthesis: Case report
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
✓Research into visual prosthetics is expected to revolutionize the treatment of blind patients with incurable outer retinal degenerative disease. Substantial evidence shows that useful visual sensations can be produced by controlled electrical stimulation of the optic nerve. To make the optic nerve visual prosthesis more acceptable, implantation techniques safer and less invasive than those previously used have been developed. A medial transconjunctival approach is now used to implant a stimulating electrode around the intraorbital section of the optic nerve. This new technique allows sufficient exposure of the nerve after detaching only one rectus muscle and performing a lateral canthotomy. Previously, an electrode was implanted in the intracranial part of the optic nerve, which required more invasive surgery. The new technique was first developed in cadavers and in patients undergoing eye enucleations. Finally, a 68- year-old blind man suffering from retinitis pigmentosa underwent long-term implantation. In this case report the authors describe the technique and outline some of the challenges involved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Pattern recognition with the optic nerve visual prosthesis
Veraart, C., Wanet‐Defalque, M., Gérard, B., Vanlierde, A., & Delbeke, J. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07305.x · Cited by 259
Cited by
Lewis, P. M., Ackland, H. M., Lowery, A. J., & Rosenfeld, J. V. (2015) · Brain Research · doi:10.1016/j.brainres.2014.11.020 · Cited by 228
Focal activation of the feline retina via a suprachoroidal electrode array
Wong, Y. T., Chen, S. C., Seo, J. M., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.018 · Cited by 109
Spatially selective activation of the visual cortex via intraneural stimulation of the optic nerve
Gaillet, V., Cutrone, A., Artoni, F., Vagni, P., Mega Pratiwi, A., Romero, S. A., Lipucci Di Paola, D., Micera, S., & Ghezzi, D. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0446-8 · Cited by 73
Contemporary approaches to visual prostheses
Mirochnik, R. M., & Pezaris, J. S. (2019) · Military Medical Research · doi:10.1186/s40779-019-0206-9 · Cited by 58
Metadata
- Authors
- Brelén, M. E., De Potter, P., Gersdorff, M., Cosnard, G., Veraart, C., & Delbeke, J.
- Venue
- Journal of Neurosurgery
- Published
- 2006-04
- Volume
- 104
- Issue
- 4
- Pages
- 593-597
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2025690166
- Cited by
- 35
- References
- 3
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraorbital implantation of a stimulating electrode for an optic nerve visual prosthesis: Case report. https://app.cochat.ai/papers/10.3171/jns.2006.104.4.593
- The paper
- Brelén, M. E., De Potter, P., Gersdorff, M., Cosnard, G., Veraart, C., & Delbeke, J. (2006). Intraorbital implantation of a stimulating electrode for an optic nerve visual prosthesis: Case report. Journal of Neurosurgery. https://doi.org/10.3171/jns.2006.104.4.593
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.