Electrocorticographically controlled brain–computer interfaces using motor and sensory imagery in patients with temporary subdural electrode implants: Report of four cases
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
✓Brain–computer interface (BCI) technology can offer individuals with severe motor disabilities greater independence and a higher quality of life. The BCI systems take recorded brain signals and translate them into real-time actions, for improved communication, movement, or perception. Four patient participants with a clinical need for intracranial electrocorticography (ECoG) participated in this study. The participants were trained over multiple sessions to use motor and/or auditory imagery to modulate their brain signals in order to control the movement of a computer cursor. Participants with electrodes over motor and/or sensory areas were able to achieve cursor control over 2 to 7 days of training. These findings indicate that sensory and other brain areas not previously considered ideal for ECoG-based control can provide additional channels of control that may be useful for a motor BCI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Cited by
Brain–computer interfaces for communication and rehabilitation
Chaudhary, U., Birbaumer, N., & Ramos-Murguialday, A. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.113 · Cited by 928
Brain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Cortical activity during motor execution, motor imagery, and imagery-based online feedback
Miller, K. J., Schalk, G., Fetz, E. E., den Nijs, M., Ojemann, J. G., & Rao, R. P. N. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0913697107 · Cited by 622
Enhanced performance by a hybrid NIRS–EEG brain computer interface
Fazli, S., Mehnert, J., Steinbrink, J., Curio, G., Villringer, A., Müller, K.-R., & Blankertz, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.084 · Cited by 599
Combrisson, E., & Jerbi, K. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.01.010 · Cited by 599
Clinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Mak, J. N., & Wolpaw, J. R. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2035356 · Cited by 509
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Two-dimensional movement control using electrocorticographic signals in humans
Schalk, G., Miller, K. J., Anderson, N. R., Wilson, J. A., Smyth, M. D., Ojemann, J. G., Moran, D. W., Wolpaw, J. R., & Leuthardt, E. C. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/008 · Cited by 482
Self-citationBrain-Computer Interfaces Using Electrocorticographic Signals
Schalk, G., & Leuthardt, E. C. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2172408 · Cited by 427
Benabid, A. L., Costecalde, T., Eliseyev, A., Charvet, G., Verney, A., Karakas, S., Foerster, M., Lambert, A., Morinière, B., Abroug, N., et al. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30321-7 · Cited by 404
An Electrocorticographic Brain Interface in an Individual with Tetraplegia
Wang, W., Collinger, J. L., Degenhart, A. D., Tyler-Kabara, E. C., Schwartz, A. B., Moran, D. W., Weber, D. J., Wodlinger, B., Vinjamuri, R. K., Ashmore, R. C., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055344 · Cited by 402
Advanced Neurotechnologies for Chronic Neural Interfaces: New Horizons and Clinical Opportunities
Kipke, D. R., Shain, W., Buzsáki, G., Fetz, E., Henderson, J. M., Hetke, J. F., & Schalk, G. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3879-08.2008 · Cited by 286
Decoding flexion of individual fingers using electrocorticographic signals in humans
Kubánek, J., Miller, K. J., Ojemann, J. G., Wolpaw, J. R., & Schalk, G. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/6/066001 · Cited by 285
Brain–computer interface in paralysis
Birbaumer, N., Murguialday, A. R., & Cohen, L. (2008) · Current Opinion in Neurology · doi:10.1097/wco.0b013e328315ee2d · Cited by 275
Hotson, G., McMullen, D. P., Fifer, M. S., Johannes, M. S., Katyal, K. D., Para, M. P., Armiger, R., Anderson, W. S., Thakor, N. V., Wester, B. A., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026017 · Cited by 201
WIMAGINE: Wireless 64-Channel ECoG Recording Implant for Long Term Clinical Applications
Mestais, C. S., Charvet, G., Sauter-Starace, F., Foerster, M., Ratel, D., & Benabid, A. L. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2333541 · Cited by 202
Flint, R. D., Wright, Z. A., Scheid, M. R., & Slutzky, M. W. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056005 · Cited by 183
Decoding Inner Speech Using Electrocorticography: Progress and Challenges Toward a Speech Prosthesis
Martin, S., Iturrate, I., Millán, J. D. R., Knight, R. T., & Pasley, B. N. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00422 · Cited by 115
“Finally, electrocorticography is suitable for neuroprosthetic and brain-computer interface applications (Leuthardt et al., 2004, 2006; Felton et al., 2007; Schalk et al., 2007; Blakely et al., 2009; Wang et al., 2013; Kapeller et al., 2014; Moses et al., 2018).”
MethodOptimizing the Decoding of Movement Goals from Local Field Potentials in Macaque Cortex
Markowitz, D. A., Wong, Y. T., Gray, C. M., & Pesaran, B. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.4165-11.2011 · Cited by 110
“…There is increasing interest in driving a neural interface using electrocorticogram (ECoG) activity recorded at the cortical surface and epidurally (Felton et al., 2007; Schalk et al., 2007; Chao et al., 2010; Moran, 2010; Slutzky et al., 2011), but thusfar, comparisons between these signal…”
MethodMa, Z.-Z., Wu, J.-J., Cao, Z., Hua, X.-Y., Zheng, M.-X., Xing, X.-X., Ma, J., & Xu, J.-G. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-024-01387-w · Cited by 97
“Thus, although these early systems established a precedent for MI, more detailed research is needed to develop a standard protocol for training with exercise-oriented BCI devices [48].”
Background
Metadata
- Authors
- Felton, E. A., Wilson, J. A., Williams, J. C., & Garell, P. C.
- Venue
- Journal of Neurosurgery
- Published
- 2007-03
- Volume
- 106
- Issue
- 3
- Pages
- 495-500
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W1966832096
- Cited by
- 154
- References
- 2
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.