CoChat
Cited by 107

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

In vivo tracking of superparamagnetic iron oxide nanoparticle–labeled mesenchymal stem cell tropism to malignant gliomas using magnetic resonance imaging: Laboratory investigation

Wu, Xing, Hu, Jin, Zhou, Liangfu, Mao, Ying, Yang, Bojie, Gao, Liang, Xie, Rong, Xu, Feng, Zhang, Dong, Liu, Jun, Zhu, Jianhong · 2008 · Journal of Neurosurgery

Abstract

Object: Mesenchymal stem cells (MSCs) have been shown to migrate toward tumors, but their distribution pattern in gliomas has not been completely portrayed. The primary purpose of the study was to assay the tropism capacity of MSCs to gliomas, to delineate the pattern of MSC distribution in gliomas after systemic injection, and to track the migration and incorporation of magnetically labeled MSCs using 1.5-T magnetic resonance (MR) imaging. Methods: The MSCs from Fischer 344 rats were colabeled with superparamagnetic iron oxide nanoparticles (SPIO) and enhanced green fluorescent protein (EGFP). The tropism capacity of MSCs was quantitatively assayed in vitro using the Transwell system. To track the migration of MSCs in vivo, MR imaging was performed both 7 and 14 days after systemic administration of labeled MSCs. After MR imaging, the distribution patterns of MSCs in rats with gliomas were examined using Prussian blue and fluorescence staining. Results: The in vitro study showed that MSCs possessed significantly greater migratory capacity than fibroblast cells (p < 0.001) and that lysis of F98 glioma cells and cultured F98 cells showed a greater capacity to induce migration of cells than other stimuli (p < 0.05). Seven days after MSC transplantation, the SPIO–EGFP colabeled cells were distributed throughout the tumor, where a well-defined dark hypointense region was represented on gradient echo sequences. After 14 days, most of the colabeled MSCs were found at the border between the tumor and normal parenchyma, which was represented on gradient echo sequences as diluted amorphous dark areas at the edge of the tumors. Conclusions: This study demonstrated that systemically transplanted MSCs migrate toward gliomas with high specificity in a temporal–spatial pattern, which can be tracked using MR imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/jns/2008/108/2/0320

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 107

Metadata

Authors
Wu, X., Hu, J., Zhou, L., Mao, Y., Yang, B., Gao, L., Xie, R., Xu, F., Zhang, D., Liu, J., & Zhu, J.
Venue
Journal of Neurosurgery
Published
2008-02
Volume
108
Issue
2
Pages
320-329
ISSN
  • 0022-3085 (ISSN-L)
  • 1933-0693
OpenAlex
W1505550085
Cited by
107
References
3
FWCI
5.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vivo tracking of superparamagnetic iron oxide nanoparticle–labeled mesenchymal stem cell tropism to malignant gliomas using magnetic resonance imaging: Laboratory investigation. https://app.cochat.ai/papers/10.3171/jns/2008/108/2/0320
The paper
Wu, X., Hu, J., Zhou, L., Mao, Y., Yang, B., Gao, L., Xie, R., Xu, F., Zhang, D., Liu, J., & Zhu, J. (2008). In vivo tracking of superparamagnetic iron oxide nanoparticle–labeled mesenchymal stem cell tropism to malignant gliomas using magnetic resonance imaging: Laboratory investigation. Journal of Neurosurgery. https://doi.org/10.3171/jns/2008/108/2/0320

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.