CoChat

Detection of infusate leakage in the brain using real-time imaging of convection-enhanced delivery: Laboratory investigation

Open access
Varenika, Vanja, Dickinson, Peter, Bringas, John, LeCouteur, Richard, Higgins, Robert, Park, John, Fiandaca, Massimo, Berger, Mitchel, Sampson, John, Bankiewicz, Krystof · 2008 · Journal of Neurosurgery
Cited by 110

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Object: The authors have shown that convection-enhanced delivery (CED) of gadoteridol-loaded liposomes (GDLs) into different regions of normal monkey brain results in predictable, widespread distribution of this tracking agent as detected by real-time MR imaging. They also have found that this tracking technique allows monitoring of the distribution of similar nanosized agents such as therapeutic liposomes and viral vectors. A limitation of this procedure is the unexpected leakage of liposomes out of targeted parenchyma or malignancies into sulci and ventricles. The aim of the present study was to evaluate the efficacy of CED after the onset of these types of leakage. Methods: The authors documented this phenomenon in a study of 5 nonhuman primates and 7 canines, comprising 54 CED infusion sessions. Approximately 20% of these infusions resulted in leakage into cerebral ventricles or sulci. All of the infusions and leakage events were monitored with real-time MR imaging. The authors created volume-distributed versus volume-infused graphs for each infusion session. These graphs revealed the rate of distribution of GDL over the course of each infusion and allowed the authors to evaluate the progress of CED before and after leakage. Results: The distribution of therapeutics within the target structure ceased to increase or resulted in significant attenuation after the onset of leakage. Conclusions: An analysis of the cases in this study revealed that leakage undermines the efficacy of CED. These findings reiterate the importance of real-time MR imaging visualization during CED to ensure an accurate, robust distribution of therapeutic agents.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/jns/2008/109/11/0874

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 110

Metadata

Authors
Varenika, V., Dickinson, P., Bringas, J., LeCouteur, R., Higgins, R., Park, J., Fiandaca, M., Berger, M., Sampson, J., & Bankiewicz, K.
Venue
Journal of Neurosurgery
Published
2008-11
Volume
109
Issue
5
Pages
874-880
ISSN
  • 0022-3085 (ISSN-L)
  • 1933-0693
OpenAlex
W1995969484
Cited by
110
References
2
FWCI
5.06
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of infusate leakage in the brain using real-time imaging of convection-enhanced delivery: Laboratory investigation. https://app.cochat.ai/papers/10.3171/jns/2008/109/11/0874
The paper
Varenika, V., Dickinson, P., Bringas, J., LeCouteur, R., Higgins, R., Park, J., Fiandaca, M., Berger, M., Sampson, J., & Bankiewicz, K. (2008). Detection of infusate leakage in the brain using real-time imaging of convection-enhanced delivery: Laboratory investigation. Journal of Neurosurgery. https://doi.org/10.3171/jns/2008/109/11/0874

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.