CoChat

Comparison of spinal cord gray matter and white matter softness: measurement by pipette aspiration method

Ozawa, Hiroshi, Matsumoto, Takeo, Ohashi, Toshiro, Sato, Masaaki, Kokubun, Shoichi · 2001 · Journal of Neurosurgery: Spine
Cited by 149

The DOI matches its Crossref record.

Abstract

Object. Although the gray matter of the spinal cord has been thought to be softer than the white matter, there is no evidence to support this belief. Because the spinal cord is extremely soft, it has been difficult to measure the mechanical properties of the gray and white matter. The modulis of elasticity of the gray and white matter were measured in situ by using a pipette aspiration method. Method. The spinal cord specimens were excised from Japanese white rabbits. Specimens were cut to display the surfaces of axial, frontal, and sagittal sections. The surfaces of the gray and white matter were aspirated using a 0.8-mm-inner-diameter glass pipette while monitoring with a video microscope, and the deformed length in the pipette was measured on a monitor. In each case the modulus of elasticity was calculated by comparing the relationship between the aspiration pressure and aspirated volume of the specimen with that determined by finite element analysis. The moduli of elasticity of the gray and white matter were 3.4 ± 1.4 kPa (mean ± standard deviation) and 3.4 ± 0.9 kPa in the axial section, 3 ± 0.3 kPa and 3.5 ± 0.5 kPa in the frontal section, and 3.5 ± 0.9 kPa and 2.8 ± 0.4 kPa in the sagittal section, respectively. Conclusions. No significant difference in modulus of elasticity was shown between the gray and white matter of the spinal in sections made in various directions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/spi.2001.95.2.0221

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 149

Metadata

Authors
Ozawa, H., Matsumoto, T., Ohashi, T., Sato, M., & Kokubun, S.
Venue
Journal of Neurosurgery: Spine
Published
2001-10
Volume
95
Issue
2
Pages
221-224
ISSN
  • 1547-5646 (ISSN-L)
  • 1547-5654
OpenAlex
W2085276454
Cited by
149
References
0
FWCI
2.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of spinal cord gray matter and white matter softness: measurement by pipette aspiration method. https://app.cochat.ai/papers/10.3171/spi.2001.95.2.0221
The paper
Ozawa, H., Matsumoto, T., Ohashi, T., Sato, M., & Kokubun, S. (2001). Comparison of spinal cord gray matter and white matter softness: measurement by pipette aspiration method. Journal of Neurosurgery: Spine. https://doi.org/10.3171/spi.2001.95.2.0221

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.