Comparison of spinal cord gray matter and white matter softness: measurement by pipette aspiration method
The DOI matches its Crossref record.
Abstract
Object. Although the gray matter of the spinal cord has been thought to be softer than the white matter, there is no evidence to support this belief. Because the spinal cord is extremely soft, it has been difficult to measure the mechanical properties of the gray and white matter. The modulis of elasticity of the gray and white matter were measured in situ by using a pipette aspiration method. Method. The spinal cord specimens were excised from Japanese white rabbits. Specimens were cut to display the surfaces of axial, frontal, and sagittal sections. The surfaces of the gray and white matter were aspirated using a 0.8-mm-inner-diameter glass pipette while monitoring with a video microscope, and the deformed length in the pipette was measured on a monitor. In each case the modulus of elasticity was calculated by comparing the relationship between the aspiration pressure and aspirated volume of the specimen with that determined by finite element analysis. The moduli of elasticity of the gray and white matter were 3.4 ± 1.4 kPa (mean ± standard deviation) and 3.4 ± 0.9 kPa in the axial section, 3 ± 0.3 kPa and 3.5 ± 0.5 kPa in the frontal section, and 3.5 ± 0.9 kPa and 2.8 ± 0.4 kPa in the sagittal section, respectively. Conclusions. No significant difference in modulus of elasticity was shown between the gray and white matter of the spinal in sections made in various directions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The stiffness of living tissues and its implications for tissue engineering
Guimarães, C. F., Gasperini, L., Marques, A. P., & Reis, R. L. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0169-1 · Cited by 1,515
Factors Influencing Optic Nerve Head Biomechanics
Sigal, I. A., Flanagan, J. G., & Ethier, C. R. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0541 · Cited by 507
Biomaterials by freeze casting
Wegst, U. G. K., Schecter, M., Donius, A. E., & Hunger, P. M. (2010) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2010.0014 · Cited by 375
Biomaterial Design Strategies for the Treatment of Spinal Cord Injuries
Straley, K. S., Foo, C. W. P., & Heilshorn, S. C. (2010) · Journal of Neurotrauma · doi:10.1089/neu.2009.0948 · Cited by 355
Strategies for body-conformable electronics
Liu, S., Rao, Y., Jang, H., Tan, P., & Lu, N. (2022) · Matter · doi:10.1016/j.matt.2022.02.006 · Cited by 306
Unraveling the riddle of syringomyelia
Greitz, D. (2006) · Neurosurgical Review · doi:10.1007/s10143-006-0029-5 · Cited by 295
Reassessment of brain elasticity for analysis of biomechanisms of hydrocephalus
Taylor, Z., & Miller, K. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.11.027 · Cited by 237
“As indicated above, the pressure magnitude was set to 3 kPa, in line with other work by Peña et al. (1999) and Nagashima et al.”
BackgroundResultCNS Cell Distribution and Axon Orientation Determine Local Spinal Cord Mechanical Properties
Koser, D. E., Moeendarbary, E., Hanne, J., Kuerten, S., & Franze, K. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.03.039 · Cited by 177
“saw no difference (35), and Kruse et al.”
Nanomaterials design and tests for neural tissue engineering
Saracino, G. A. A., Cigognini, D., Silva, D., Caprini, A., & Gelain, F. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35065c · Cited by 172
Independent tuning of multiple biomaterial properties using protein engineering
Straley, K. S., & Heilshorn, S. C. (2009) · Soft Matter · doi:10.1039/b808504h · Cited by 163
Oh, N., Hwang, J., Kang, M. S., Yoo, C.-Y., Kwak, M., & Han, D.-W. (2025) · Biomaterials Research · doi:10.34133/bmr.0183 · Cited by 25
A paradigm shift: Bioengineering meets mechanobiology towards overcoming remyelination failure
Carvalho, E. D., Morais, M. R. G., Ferreira, H. P., Silva, M. M. C., Guimarães, S. C., & Pêgo, A. P. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121427 · Cited by 16
Metadata
- Authors
- Ozawa, H., Matsumoto, T., Ohashi, T., Sato, M., & Kokubun, S.
- Venue
- Journal of Neurosurgery: Spine
- Published
- 2001-10
- Volume
- 95
- Issue
- 2
- Pages
- 221-224
- ISSN
- 1547-5646 (ISSN-L)
- 1547-5654
- OpenAlex
- W2085276454
- Cited by
- 149
- References
- 0
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.