Reproducibility, Interrater Agreement, and Age-Related Changes of Fractional Anisotropy Measures at 3T in Healthy Subjects: Effect of the Applied b-Value
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND PURPOSE: There is no reproducibility study of fractional anisotropy (FA) measurements at 3T using regions of interest (ROIs). Our purpose was to establish the extent and statistical significance of the interrater variability, the variability observed with 2 different b-values, and in 2 separate scanning sessions. MATERIALS AND METHODS: Twelve healthy volunteers underwent MR imaging twice. MR imaging was performed on a 3T unit, and FA maps were analyzed independently by 2 observers using ROIs positioned in the corpus callosum, internal capsules, corticospinal tracts, and right thalamus. Changes in FA values (x10(3)) measured with 2 b-values (700 and 1000 s/mm(2)), age-related differences, interobserver agreement, and measurement reproducibility were assessed. RESULTS: In the right internal capsule genu (FA = 702/728; b = 1000/700 s/mm(2)) and the left anterior limb of the internal capsule (AIC; FA = 617/745; b = 1000/700 s/mm(2)), the FA values were significantly different between the 2 b-values (P = .02 and .05, respectively). Significant age-related differences in FA were observed in the genu of the corpus callosum and in the left AIC. Interrater measurements showed fair-to-moderate agreement for most anatomic structures. The lowest significant change for a single subject regarding any FA values between the 2 sessions was in the corpus callosum (4%), whereas the highest one was in the corticospinal tracts (27%). The Bland-Altman plot analysis showed that the 1000-s/mm(2) b-value gave satisfactorily reproducible measurements equally good or better than the 700-s/mm(2) b-value. CONCLUSION: The reproducibility of FA estimates using ROIs was satisfactory. Measurements with a b-value at 1000 s/mm(2) showed superior reproducibility in most anatomic locations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Diffusion tensor imaging and aging—A review.
Moseley, M. (2002) · NMR in Biomedicine · doi:10.1002/nbm.785 · Cited by 302
From diffusion tractography to quantitative white matter tract measures: a reproducibility study
Ciccarelli, O., Parker, G. J. M., Toosy, A. T., Wheeler-Kingshott, C. A. M., Barker, G. J., Boulby, P. A., Miller, D. H., & Thompson, A. J. (2003) · NeuroImage · doi:10.1016/s1053-8119(02)00042-3 · Cited by 228 · cited 2×
“ues of deviation and variability that characterize any repeated measurements.(16,17) To our knowledge, the evidence of DTI reproducibility on 3T units in adults is limited and investi-”
BackgroundResult
Cited by
Vollmar, C., O'Muircheartaigh, J., Barker, G. J., Symms, M. R., Thompson, P., Kumari, V., Duncan, J. S., Richardson, M. P., & Koepp, M. J. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.046 · Cited by 259
Fox, R. J., Sakaie, K., Lee, J.-C., Debbins, J. P., Liu, Y., Arnold, D. L., Melhem, E. R., Smith, C. H., Philips, M. D., Lowe, M., et al. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2844 · Cited by 137
“Scanrescan reproducibility of DTI measures with 3T scanners has been previously published and has been satisfactory for FA and ADC values ( 5%).(20,21) In our study, we have additionally determined regional values for diffusivity measures and found them to be comparable.”
MethodPalacios, E. M., Martin, A. J., Boss, M. A., Ezekiel, F., Chang, Y. S., Yuh, E. L., Vassar, M. J., Schnyer, D. M., MacDonald, C. L., Crawford, K. L., et al. (2017) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5025 · Cited by 110
Reproducibility of tract‐based white matter microstructural measures using the ENIGMA ‐ DTI protocol
Acheson, A., Wijtenburg, S. A., Rowland, L. M., Winkler, A., Mathias, C. W., Hong, L. E., Jahanshad, N., Patel, B., Thompson, P. M., McGuire, S. A., et al. (2017) · Brain and Behavior · doi:10.1002/brb3.615 · Cited by 43
Cavedo, E., Lista, S., Rojkova, K., Chiesa, P. A., Houot, M., Brueggen, K., Blautzik, J., Bokde, A. L. W., Dubois, B., Barkhof, F., et al. (2017) · Neuroscience · doi:10.1016/j.neuroscience.2017.05.048 · Cited by 40
“…of the FA values on the applied b-value, found significantly different mean FA values between the DTI acquisitions using a bvalue of 700 s/mm2 and those using a b-value of 1000 s/mm2 in the genu of right internal capsule and the anterior limb of left internal capsule (Bisdas et al., 2008).”
Method
Metadata
- Authors
- Bisdas, S., Bohning, D. E., Bešenski, N., Nicholas, J. S., & Rumboldt, Z.
- Venue
- American Journal of Neuroradiology
- Published
- 2008-03-27
- Volume
- 29
- Issue
- 6
- Pages
- 1128-1133
- ISSN
- 0195-6108 (ISSN-L)
- 1936-959X
- OpenAlex
- W2123932487
- Cited by
- 81
- References
- 4
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.