Legionella Infection Risk from Domestic Hot Water
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
We investigated Legionella and Pseudomonas contamination of hot water in a cross-sectional multicentric survey in Italy. Chemical parameters (hardness, free chlorine, and trace elements) were determined. Legionella spp. were detected in 33 (22.6%) and Pseudomonas spp. in 56 (38.4%) of 146 samples. Some factors associated with Legionella contamination were heater type, tank distance and capacity, water plant age, and mineral content. Pseudomonas presence was influenced by water source, hardness, free chlorine, and temperature. Legionella contamination was associated with a centralized heater, distance from the heater point >10 m, and a water plant >10 years old. Furthermore, zinc levels of <100 microg/L and copper levels of >50 microg/L appeared to be protective against Legionella colonization [corrected]. Legionella species and serogroups were differently distributed according to heater type, water temperature, and free chlorine, suggesting that Legionella strains may have a different sensibility and resistance to environmental factors and different ecologic niches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yu, V. L., Plouffe, J. F., Pastoris, M. C., Stout, J. E., Schousboe, M., Widmer, A., Summersgill, J., File, T., Heath, C. M., Paterson, D. L., et al. (2002) · The Journal of Infectious Diseases · doi:10.1086/341087 · Cited by 663 · cited 1×
“pneumophila serogroup 1, responsible for approximately 80%–90% of Legionnaires’ disease cases (32), was predominantly isolated from independent water heating systems, despite the fact that they were less frequently contaminated.”
BackgroundThe Hospital Water Supply as a Source of Nosocomial Infections: A Plea for Action
Anaissie, E. J., Penzak, S. R., & Dignani, M. C. (2002) · Archives of Internal Medicine · doi:10.1001/archinte.162.13.1483 · Cited by 374 · cited 1×
“The first evidence of the association between potable water from shower and nosocomial legionellosis was reported approximately 20 years ago (1), and the hot water system is thought to be the most frequent source of cases or outbreaks within a hospital (2,3), where patients may be at a higher risk for a severe infecti…”
BackgroundRole of biofilms in the survival of Legionella pneumophila in a model potable-water system
Murga, R., Pruckler, J. M., Forster, T. S., et al. (2001) · Microbiology · doi:10.1099/00221287-147-11-3121 · Cited by 325 · cited 1×
“pneumophila (12,13), interfering with efforts to eradicate bacteria from water systems (14,15).”
BackgroundLegionella : from environmental habitats to disease pathology, detection and control
Atlas, R. M. (1999) · Environmental Microbiology · doi:10.1046/j.1462-2920.1999.00046.x · Cited by 306 · cited 1×
“Relatively little is known about sporadically occurring cases of community-acquired legionellosis, which accounts for most infections (7,8), although correlation analyses suggest that a substantial proportion of these cases may be residentially acquired and associated with bacteria in hot water distribution systems (9…”
BackgroundCombining the Antidepressant Drugs
(1965) · The Lancet · doi:10.1016/s0140-6736(65)92230-0 · Cited by 299
Legionella pneumophila: an aquatic microbe goes astray
Steinert, M. (2002) · FEMS Microbiology Reviews · doi:10.1016/s0168-6445(02)00093-1 · Cited by 291
Rogers, J., Dowsett, A. B., Dennis, P. J., Lee, J. V., & Keevil, C. W. (1994) · Applied and Environmental Microbiology · doi:10.1128/aem.60.5.1585-1592.1994 · Cited by 285 · cited 1×
“have been isolated from water with a temperature as high as 63°C, and the contamination is associated with other bacteria and protozoa (10,11).”
BackgroundChlorine resistance patterns of bacteria from two drinking water distribution systems
Ridgway, H. F., & Olson, B. H. (1982) · Applied and Environmental Microbiology · doi:10.1128/aem.44.4.972-987.1982 · Cited by 252
Momba, M. N. B., Kfir, R., Venter, S. N., & Cloete, T. E. (2000) · UpSpace Institutional Repository (University of Pretoria) · Cited by 186
Risk Factors for Domestic Acquisition of Legionnaires Disease
Straus, W. L. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.1996.00440140115011 · Cited by 182
Cited by
The role of biofilms and protozoa in Legionella pathogenesis: implications for drinking water
Lau, H. Y., & Ashbolt, N. J. (2009) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2009.04208.x · Cited by 285
Probiotic Approach to Pathogen Control in Premise Plumbing Systems? A Review
Wang, H., Edwards, M. A., Falkinham, J. O., & Pruden, A. (2013) · Environmental Science & Technology · doi:10.1021/es402455r · Cited by 175
Protopapadaki, C., & Saelens, D. (2017) · Applied Energy · doi:10.1016/j.apenergy.2016.11.103 · Cited by 147
Portier, E., Zheng, H., Sahr, T., Burnside, D. M., Mallama, C., Buchrieser, C., Cianciotto, N. P., & Héchard, Y. (2015) · Environmental Microbiology · doi:10.1111/1462-2920.12604 · Cited by 49
“These Gram-negative bacteria are found in freshwater environments, as well as in anthropogenic niches, like cooling towers, air conditioning systems or hot water pipes (Koide et al., 1993; Borella et al., 2004).”
Metadata
- Authors
- Borella, P., Montagna, M. T., Romano-Spica, V., Stampi, S., Stancanelli, G., Triassi, M., Neglia, R., Marchesi, I., Fantuzzi, G., Tatò, D., Napoli, C., Quaranta, G., Laurenti, P., Leoni, E., De Luca, G., Ossi, C., Moro, M., & D’Alcalà, G. R.
- Venue
- Emerging Infectious Diseases
- Published
- 2004-03
- Volume
- 10
- Issue
- 3
- Pages
- 457-464
- ISSN
- 1080-6040 (ISSN-L)
- 1080-6059
- OpenAlex
- W2147146643
- Cited by
- 212
- References
- 23
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.