CoChat

Comparison of 3 Infrared Thermal Detection Systems and Self-Report for Mass Fever Screening

Open access
Nguyen, An V., Cohen, Nicole J., Lipman, Harvey, Brown, Clive M., Molinari, Noelle-Angelique, Jackson, William L., Kirking, Hannah, Szymanowski, Paige, Wilson, Todd W., Salhi, Bisan A., Roberts, Rebecca R., Stryker, David W., Fishbein, Daniel B. · 2010 · Emerging Infectious Diseases
Cited by 138

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Despite limited evidence regarding their utility, infrared thermal detection systems (ITDS) are increasingly being used for mass fever detection. We compared temperature measurements for 3 ITDS (FLIR ThermoVision A20M [FLIR Systems Inc., Boston, MA, USA], OptoTherm Thermoscreen [OptoTherm Thermal Imaging Systems and Infrared Cameras Inc., Sewickley, PA, USA], and Wahl Fever Alert Imager HSI2000S [Wahl Instruments Inc., Asheville, NC, USA]) with oral temperatures (≥ 100 °F = confirmed fever) and self-reported fever. Of 2,873 patients enrolled, 476 (16.6%) reported a fever, and 64 (2.2%) had a confirmed fever. Self-reported fever had a sensitivity of 75.0%, specificity 84.7%, and positive predictive value 10.1%. At optimal cutoff values for detecting fever, temperature measurements by OptoTherm and FLIR had greater sensitivity (91.0% and 90.0%, respectively) and specificity (86.0% and 80.0%, respectively) than did self-reports. Correlations between ITDS and oral temperatures were similar for OptoTherm (ρ = 0.43) and FLIR (ρ = 0.42) but significantly lower for Wahl (ρ = 0.14; p < 0.001). When compared with oral temperatures, 2 systems (OptoTherm and FLIR) were reasonably accurate for detecting fever and predicted fever better than self-reports.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3201/eid1611.100703

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 138

Metadata

Authors
Nguyen, A. V., Cohen, N. J., Lipman, H., Brown, C. M., Molinari, N.-A., Jackson, W. L., Kirking, H., Szymanowski, P., Wilson, T. W., Salhi, B. A., Roberts, R. R., Stryker, D. W., & Fishbein, D. B.
Venue
Emerging Infectious Diseases
Published
2010-11
Volume
16
Issue
11
Pages
1710-1717
ISSN
  • 1080-6040 (ISSN-L)
  • 1080-6059
OpenAlex
W2114952204
Cited by
138
References
5
FWCI
3.86
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of 3 Infrared Thermal Detection Systems and Self-Report for Mass Fever Screening. https://app.cochat.ai/papers/10.3201/eid1611.100703
The paper
Nguyen, A. V., Cohen, N. J., Lipman, H., Brown, C. M., Molinari, N.-A., Jackson, W. L., Kirking, H., Szymanowski, P., Wilson, T. W., Salhi, B. A., Roberts, R. R., Stryker, D. W., & Fishbein, D. B. (2010). Comparison of 3 Infrared Thermal Detection Systems and Self-Report for Mass Fever Screening. Emerging Infectious Diseases. https://doi.org/10.3201/eid1611.100703

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.