Validation of magnetocardiography versus fractional flow reserve for detection of coronary artery disease
The DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Although magnetocardiography (MCG) has been proposed as a non-invasive technique with high accuracy for functional diagnosis of myocardial injury, the validation of MCG against fractional flow reserve FFR in diagnosing coronary artery disease (CAD) has not yet been established. The goal of the study was to determine the diagnostic accuracy of MCG versus invasively determined FFR in patients with suspected or known CAD. METHODS: Forty seven patients with suspected CAD (35 men; mean age 69 years) who underwent coronary angiography and FFR measurement were enrolled. FFR ≤ 0.8 was considered to indicate significant myocardial ischemia. The change of ST-segment fluctuation score from rest to stress was calculated from the MCG. In addition, two blinded cardiologists assessed MCG images that were visualized by post-processing method, bull's-eye mapping. RESULTS: The best cut-off value of the percent change of ST-segment fluctuation score was -39.0% with sensitivity of 86.7% and specificity of 73.9%. Sensitivity, specificity, diagnostic accuracy, and the area under the receiver-operator characteristics curve of bull's-eye mapping for the detection of significant CAD were 90.5%, 92.3%, 91.5%, and 0.914 on a patient basis and 90.0%, 93.8%, 92.3%, and 0.919 by coronary territory, respectively. CONCLUSIONS: MCG accurately detects functionally significant CAD as defined by using FFR, provides an assessment of ischemic status in agreement with the change of ST-segment fluctuation score, and accurately localizes the ischemic territory in bull's eye mapping. Therefore, MCG may provide an incremental value for prediction of myocardial ischemia non-invasively and safely in clinical practice with fast examination time.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The usefulness of MCG for a better understanding of the arrhythmogenic mechanisms underlying the high-risk J syndromes (225, 327–336); the identification of atrial arrhythmogenic vulnerability (248), of left atrial dysfunction (330), and of the atrial propagation pathways (228); and the dominant frequencies (181, 183, 189, 232) in patients with atrial fibrillation, as well as providing accurate”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [333]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging:, Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., et al. (2002) · Circulation · doi:10.1161/hc0402.102975 · Cited by 6,990
Heart Disease and Stroke Statistics—2013 Update: A Report From the American Heart Association
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., Fox, C. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828124ad · Cited by 5,292
Fractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary Intervention
Tonino, P. A. L., De Bruyne, B., Pijls, N. H. J., Siebert, U., Ikeno, F., van `t Veer, M., Klauss, V., Manoharan, G., Engstrøm, T., Oldroyd, K. G., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0807611 · Cited by 4,260
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Shaw, L. J., Berman, D. S., Maron, D. J., Mancini, G. B. J., Hayes, S. W., Hartigan, P. M., Weintraub, W. S., O’Rourke, R. A., Dada, M., Spertus, J. A., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.743963 · Cited by 1,605
Percutaneous Coronary Intervention of Functionally Nonsignificant Stenosis
Pijls, N. H. J., van Schaardenburgh, P., Manoharan, G., Boersma, E., Bech, J.-W., van’t Veer, M., Bär, F., Hoorntje, J., Koolen, J., Wijns, W., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.087 · Cited by 1,516
Pijls, N. H. J., Fearon, W. F., Tonino, P. A. L., Siebert, U., Ikeno, F., Bornschein, B., van't Veer, M., Klauss, V., Manoharan, G., Engstrøm, T., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.04.012 · Cited by 1,158
Scanlon, P. J., Faxon, D. P., Audet, A.-M., Carabello, B., Dehmer, G. J., Eagle, K. A., Legako, R. D., Leon, D. F., Murray, J. A., Nissen, S. E., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00126-6 · Cited by 1,123
Kajander, S., Joutsiniemi, E., Saraste, M., Pietilä, M., Ukkonen, H., Saraste, A., Sipilä, H. T., Teräs, M., Mäki, M., Airaksinen, J., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.915009 · Cited by 402
Cited by
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Magnetocardiography for the detection of myocardial ischemia
Her, A., Dischl, D., Kim, Y. H., Kim, S., & Shin, E. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1242215 · Cited by 67
Self-citationZheng, W., Su, S., Zhang, G., Bi, X., & Lin, Q. (2019) · Biomedical Optics Express · doi:10.1364/boe.380314 · Cited by 49
Shin, E., Lam, Y., Her, A., Brachmann, J., Jung, F., & Park, J. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.11.165 · Cited by 39
“Moreover, MCG accurately detects functionally significant CAD as defined by using fractional flow reserve (FFR), and provides an assessment of ischemic status in agreement with the percent change of ST-segment fluctuation score [16].”
MethodSelf-citationMagnetocardiography Using a Magnetoresistive Sensor Array
Shirai, Y., Hirao, K., Shibuya, T., Okawa, S., Hasegawa, Y., Adachi, Y., Sekihara, K., & Kawabata, S. (2019) · International Heart Journal · doi:10.1536/ihj.18-002 · Cited by 29
Metadata
- Authors
- Park, J.-W., Shin, E.-S., Ann, S. H., Gödde, M., Park, L. S.-I., Brachmann, J., Vidal-Lopez, S., Wierzbinski, J., Lam, Y.-Y., & Jung, F.
- Affiliations
- Klinikum Coburg (DE)
- University of Ulsan (KR)
- Coburg Hospital, 2nd Medical Department, Coburg, Germany
- Asklepios Klinikum Harburg (DE)
- Chinese University of Hong Kong (HK)
- Saarland University (DE)
- Venue
- Clinical Hemorheology and Microcirculation
- Publisher
- SAGE Publications
- Published
- 2015
- Volume
- 59
- Issue
- 3
- Pages
- 267-281
- ISSN
- 1386-0291 (ISSN-L)
- OpenAlex
- W2138511017
- Cited by
- 29
- References
- 52
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 4 · 2023: 3 · 2022: 2 · 2020: 1 · 2019: 5 · 2018: 3 · 2017: 2 · 2016: 1 · 2015: 1
- FWCI
- 1.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Hemorheology and Microcirculation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Coronary Interventions and Diagnostics
- Keywords
- magnetocardiography, fractional flow reserve, coronary artery disease, myocardial ischemia, diagnostic accuracy, non-invasive diagnosis
- MeSH terms
- Aged, Aged, 80 and over, Coronary Artery Disease, Female, Humans, Male, Middle Aged, Prospective Studies, Myocardial Ischemia, Coronary Stenosis, Magnetocardiography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.