CoChat

Validation of magnetocardiography versus fractional flow reserve for detection of coronary artery disease

The DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Although magnetocardiography (MCG) has been proposed as a non-invasive technique with high accuracy for functional diagnosis of myocardial injury, the validation of MCG against fractional flow reserve FFR in diagnosing coronary artery disease (CAD) has not yet been established. The goal of the study was to determine the diagnostic accuracy of MCG versus invasively determined FFR in patients with suspected or known CAD. METHODS: Forty seven patients with suspected CAD (35 men; mean age 69 years) who underwent coronary angiography and FFR measurement were enrolled. FFR ≤ 0.8 was considered to indicate significant myocardial ischemia. The change of ST-segment fluctuation score from rest to stress was calculated from the MCG. In addition, two blinded cardiologists assessed MCG images that were visualized by post-processing method, bull's-eye mapping. RESULTS: The best cut-off value of the percent change of ST-segment fluctuation score was -39.0% with sensitivity of 86.7% and specificity of 73.9%. Sensitivity, specificity, diagnostic accuracy, and the area under the receiver-operator characteristics curve of bull's-eye mapping for the detection of significant CAD were 90.5%, 92.3%, 91.5%, and 0.914 on a patient basis and 90.0%, 93.8%, 92.3%, and 0.919 by coronary territory, respectively. CONCLUSIONS: MCG accurately detects functionally significant CAD as defined by using FFR, provides an assessment of ischemic status in agreement with the change of ST-segment fluctuation score, and accurately localizes the ischemic territory in bull's eye mapping. Therefore, MCG may provide an incremental value for prediction of myocardial ischemia non-invasively and safely in clinical practice with fast examination time.

Overview

Integrity signals

Registry

Crossref · 10.3233/ch-141912

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 51 references

Cited by

Metadata

Authors
Park, J.-W., Shin, E.-S., Ann, S. H., Gödde, M., Park, L. S.-I., Brachmann, J., Vidal-Lopez, S., Wierzbinski, J., Lam, Y.-Y., & Jung, F.
Affiliations
  • Klinikum Coburg (DE)
  • University of Ulsan (KR)
  • Coburg Hospital, 2nd Medical Department, Coburg, Germany
  • Asklepios Klinikum Harburg (DE)
  • Chinese University of Hong Kong (HK)
  • Saarland University (DE)
Venue
Clinical Hemorheology and Microcirculation
Published
2015
Volume
59
Issue
3
Pages
267-281
ISSN
1386-0291 (ISSN-L)
OpenAlex
W2138511017
Cited by
29
References
52
Citations by year
2026: 2 · 2025: 5 · 2024: 4 · 2023: 3 · 2022: 2 · 2020: 1 · 2019: 5 · 2018: 3 · 2017: 2 · 2016: 1 · 2015: 1
FWCI
1.89
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Hemorheology and Microcirculation (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Coronary Interventions and Diagnostics
Keywords
magnetocardiography, fractional flow reserve, coronary artery disease, myocardial ischemia, diagnostic accuracy, non-invasive diagnosis
MeSH terms
Aged, Aged, 80 and over, Coronary Artery Disease, Female, Humans, Male, Middle Aged, Prospective Studies, Myocardial Ischemia, Coronary Stenosis, Magnetocardiography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.