CoChat

Comparison of Two Analytical Platforms for the Clinical Qualification of Alzheimer's Disease Biomarkers in Pathologically-Confirmed Dementia

Le Bastard, Nathalie, Coart, Els, Vanderstichele, Hugo, Vanmechelen, Eugeen, Martin, Jean-Jacques, Engelborghs, Sebastiaan · 2012 · Journal of Alzheimer's Disease
Cited by 55

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Combined analysis of the Alzheimer's disease (AD) biomarkers amyloid-β(1-42) (Aβ(1-42)), total tau (T-tau), and hyperphosphorylated tau (P-tau(181P)) in cerebrospinal fluid (CSF) reduces the uncertainty associated with clinical dementia diagnosis. The present study evaluated the diagnostic accuracy of the CSF biomarker concentrations obtained with a multi-analyte Luminex assay (INNO-BIA AlzBio3) in comparison to single-analyte ELISA tests (INNOTEST). Data from 66 pathologically-confirmed dementia patients (51 AD and 15 non-AD) and 95 controls were included. Cut-off values were determined for each individual biomarker determined using both methods for different diagnostic challenges (dementia-controls; AD-controls; AD-non-AD). Comparing the diagnostic accuracy of individual cut-off values between INNO-BIA and INNOTEST, no relevant differences could be identified. Logistic regression was used in addition to identify the best combination of predictor variables (biomarkers). Discrimination of dementia patients from controls using Aβ(1-42) and T-tau yielded a diagnostic accuracy of 0.87 and 0.90 for INNO-BIA and INNOTEST, respectively. Discriminating AD patients from controls, the diagnostic accuracy was 0.90 and 0.93 for INNO-BIA and INNOTEST, respectively. Optimal discrimination of AD and non-AD patients was achieved by combining Aβ(1-42) and P-tau(181P) (diagnostic accuracy = 0.86). In conclusion, which AD biomarkers or combination thereof are most informative is dependent on the differential diagnosis, but the clinical value of these markers in each of the differential diagnoses is independent of the method by which concentrations are determined. Since the clinical value of the ELISA (INNOTEST) and Luminex (INNO-BIA) tests is comparable, further research to select the most suitable analytical platform for routine CSF biomarker measurements is needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3233/jad-2012-121246

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 55

Metadata

Authors
Le Bastard, N., Coart, E., Vanderstichele, H., Vanmechelen, E., Martin, J.-J., & Engelborghs, S.
Venue
Journal of Alzheimer's Disease
Published
2012-12-03
Volume
33
Issue
1
Pages
117-131
ISSN
  • 1387-2877 (ISSN-L)
  • 1875-8908
OpenAlex
W1584579212
Cited by
55
References
15
FWCI
5.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Two Analytical Platforms for the Clinical Qualification of Alzheimer's Disease Biomarkers in Pathologically-Confirmed Dementia. https://app.cochat.ai/papers/10.3233/jad-2012-121246
The paper
Le Bastard, N., Coart, E., Vanderstichele, H., Vanmechelen, E., Martin, J.-J., & Engelborghs, S. (2012). Comparison of Two Analytical Platforms for the Clinical Qualification of Alzheimer's Disease Biomarkers in Pathologically-Confirmed Dementia. Journal of Alzheimer's Disease. https://doi.org/10.3233/jad-2012-121246

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.