Discrimination of physiological tremor from pathological tremor using accelerometer and surface EMG signals
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND OBJECTIVE: Although careful clinical examination and medical history are the most important steps towards a diagnostic separation between different tremors, the electro-physiological analysis of the tremor using accelerometry and electromyography (EMG) of the affected limbs are promising tools. METHODS: A soft-decision wavelet-based decomposition technique is applied with 8 decomposition stages to estimate the power spectral density of accelerometer and surface EMG signals (sEMG) sampled at 800 Hz. A discrimination factor between physiological tremor (PH) and pathological tremor, namely, essential tremor (ET) and the tremor caused by Parkinson’s disease (PD), is obtained by summing the power entropy in band 6 (B6: 7.8125–9.375 Hz) and band 11 (B11: 15.625–17.1875 Hz). RESULTS: A discrimination accuracy of 93.87% is obtained between the PH group and the ET & PD group using a voting between three results obtained from the accelerometer signal and two sEMG signals. CONCLUSION: Biomedical signal processing techniques based on high resolution wavelet spectral analysis of accelerometer and sEMG signals are implemented to efficiently perform classification between physiological tremor and pathological tremor.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Previous research has shown the effectiveness of power spectral analysis of acceleration signal is effective in the detection of tremor24,39–41.”
From Wearable sensors during drawing tasks to measure the severity of essential tremor (2022) · cites this paper as [40]
Citations
Cites
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981
Self-citationThe cerebral oscillatory network of parkinsonian resting tremor
Timmermann, L., Gross, J., Dirks, M., Volkmann, J., Freund, H.-J., & Schnitzler, A. (2003) · Brain · doi:10.1093/brain/awg022 · Cited by 544
Physiological and pathological tremors and rhythmic central motor control
McAuley, J. H. (2000) · Brain · doi:10.1093/brain/123.8.1545 · Cited by 509
Cohen, O., Pullman, S., Jurewicz, E., Watner, D., & Louis, E. D. (2003) · Archives of Neurology · doi:10.1001/archneur.60.3.405 · Cited by 298
McAuley, J. H., Rothwell, J. C., & Marsden, C. D. (1997) · Experimental Brain Research · doi:10.1007/pl00005662 · Cited by 285
Elble, R. J. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00004 · Cited by 271
Load-Independent Contributions From Motor-Unit Synchronization to Human Physiological Tremor
Halliday, D. M., Conway, B. A., Farmer, S. F., & Rosenberg, J. R. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.2.664 · Cited by 224
Clinical Neurophysiology of Tremor
Deuschl, G., Krack, P., Lauk, M., & Timmer, J. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00002 · Cited by 210
Self-citationTremor-correlated cortical activity in essential tremor
Hellwig, B., Häußler, S., Schelter, B., Lauk, M., Guschlbauer, B., Timmer, J., & Lücking, C. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04044-7 · Cited by 202
(2000) · PubMed · Cited by 193
Self-citationMechanical factors in human tremor frequency
Stiles, R. N., & Randall, J. E. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.3.324 · Cited by 191
Essential tremor frequency decreases with time
Elble, R. J. (2000) · Neurology · doi:10.1212/wnl.55.10.1547 · Cited by 166
Characteristics of physiologic tremor in young and elderly adults
Elble, R. J. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00006-3 · Cited by 163
Cortical Involvement in the Generation of Essential Tremor
Raethjen, J., Govindan, R. B., Kopper, F., Muthuraman, M., & Deuschl, G. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00477.2006 · Cited by 152
Self-citationCerebello-cortical network fingerprints differ between essential, Parkinson’s and mimicked tremors
Muthuraman, M., Raethjen, J., Koirala, N., Anwar, A. R., Mideksa, K. G., Elble, R. J., Groppa, S., & Deuschl, G. (2018) · Brain · doi:10.1093/brain/awy098 · Cited by 147
Self-citationAmplitude changes in the 8–12, 20–25, and 40 Hz oscillations in finger tremor
Vaillancourt, D. E., & Newell, K. M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00378-3 · Cited by 106
A Review on Techniques for Tremor Recording and Quantification
Mansur, P. H. G., Cury, L. K. P., Andrade, A. O., Pereira, A. A., Miotto, G. A. A., Soares, A. B., & Naves, E. L. M. (2007) · Critical Reviews™ in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v35.i5.10 · Cited by 100
The effects of unilateral muscle fatigue on bilateral physiological tremor
Morrison, S., Kavanagh, J. J., Obst, S. J., Irwin, J., & Haseler, L. J. (2005) · Experimental Brain Research · doi:10.1007/s00221-005-0050-x · Cited by 80
van der Stouwe, A. M. M., Elting, J. W. J., van der Hoeven, J. H., van Laar, T., Leenders, K. L., Maurits, N. M., & Tijssen, M. A. J. (2016) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2016.06.008 · Cited by 78
Tremor analysis in two normal cohorts
Raethjen, J., Lauk, M., Köster, B., Fietzek, U. M., Friege, L., Timmer, J., Lücking, C. H., & Deuschl, G. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.04.006 · Cited by 66
Self-citationTremor classification and tremor time series analysis
Deuschl, G., Lauk, M., & Timmer, J. (1995) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166084 · Cited by 66
Self-citationThe resonant component of human physiological hand tremor is altered by slow voluntary movements
Lakie, M., Vernooij, C. A., Osborne, T. M., & Reynolds, R. F. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2011.226449 · Cited by 66
Long-term EMG recordings differentiate between parkinsonian and essential tremor
Breit, S., Spieker, S., Schulz, J. B., & Gasser, T. (2008) · Journal of Neurology · doi:10.1007/s00415-008-0712-2 · Cited by 63
Borges, V., & Ferraz, H. B. (2001) · Revista Neurociências · doi:10.34024/rnc.2006.v14.8786 · Cited by 62
Antonini, A., Berto, P., Lopatriello, S., Tamma, F., Annemans, L., & Chambers, M. (2008) · Movement Disorders · doi:10.1002/mds.22278 · Cited by 58
Harris, M. K., Shneyder, N., Borazanci, A., Korniychuk, E., Kelley, R. E., & Minagar, A. (2009) · Medical Clinics of North America · doi:10.1016/j.mcna.2008.09.002 · Cited by 58
Hossen, A., Muthuraman, M., Raethjen, J., Deuschl, G., & Heute, U. (2010) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2010.02.005 · Cited by 57
Self-citationReliability, specificity and sensitivity of long-term tremor recordings
Spieker, S., Jentgens, C., Boose, A., & DICHGANS, J. (1995) · Electroencephalography and Clinical Neurophysiology/Electromyography and Motor Control · doi:10.1016/0924-980x(95)00208-3 · Cited by 50
Quantifying the importance of high frequency components on the amplitude of physiological tremor
Carignan, B., Daneault, J., & Duval, C. (2009) · Experimental Brain Research · doi:10.1007/s00221-009-2132-7 · Cited by 45
[123I]-FP-CIT SPECT and olfaction test in patients with combined postural and rest tremor
Djaldetti, R., Nageris, B. I., Lorberboym, M., Treves, T. A., Melamed, E., & Yaniv, E. (2008) · Journal of Neural Transmission · doi:10.1007/s00702-007-0851-0 · Cited by 39
Detecting scaling in the period dynamics of multimodal signals: Application to Parkinsonian tremor
Sapir, N., Karasik, R., Havlin, S., Simon, E., & Hausdorff, J. M. (2003) · Physical Review E · doi:10.1103/physreve.67.031903 · Cited by 35
Hossen, A., Ghunaimi, B. A., & Hassan, M. O. (2004) · Signal Processing · doi:10.1016/j.sigpro.2004.09.004 · Cited by 35
Self-citationPower spectral density estimation via wavelet decomposition
Hossen, A. (2004) · Electronics Letters · doi:10.1049/el:20045235 · Cited by 33
Self-citationA wavelet-based soft decision technique for screening of patients with congestive heart failure
Hossen, A., & Ghunaimi, B. A. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.05.008 · Cited by 26
Self-citationWharrad, H. J., & Jefferson, D. (2000) · Human Movement Science · doi:10.1016/s0167-9457(00)00017-8 · Cited by 19
Hossen, A. (2005) · Technology and Health Care · doi:10.3233/thc-2005-13302 · Cited by 18
Self-citationThe origins of physiological tremor as deduced from immersions of the finger in various liquids
Takanokura, M., Kokuzawa, N., & Sakamoto, K. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0677-2 · Cited by 18
Coordination of the upper-limb segments in physiological tremor with various external loads.
Takanokura, M., Makabe, H., Kaneko, K., Mito, K., & Sakamoto, K. (2007) · PubMed · Cited by 9
Aspectos genéticos da Esclerose Lateral Amiotrófica
Magalhães, M. L., & Zatz, M. (1999) · Revista Neurociências · doi:10.34024/rnc.2006.v14.8769 · Cited by 4
Research works printed but not linked: 2
- Marshall, 2008, Parkinson’s disease is over diagnosed clinically at baseline in diagnostically uncertain cases: A 3-year European multicenter study with repeat [(123)] FP-CIT SPECT, Mov Disord, 24, 499
- Deuschl, 1998, Consensus statement of the movement disorder society on tremor. Ad hoc scientific committee, Moving Disorders, 13, 2, 10.1002/mds.870131303 · DOI · Paper page
Cited by
Wearable sensors during drawing tasks to measure the severity of essential tremor
Ali, S. M., Arjunan, S. P., Peters, J., Perju-Dumbrava, L., Ding, C., Eller, M., Raghav, S., Kempster, P., Motin, M. A., Radcliffe, P. J., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-08922-6 · Cited by 35
Upper limb intention tremor assessment: opportunities and challenges in wearable technology
Paredes-Acuña, N., Utpadel-Fischler, D., Ding, K., Thakor, N. V., & Cheng, G. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01302-9 · Cited by 27
Liu, J., Sun, L., Liu, J., Min, H., Xu, Y., & Li, R. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.884475 · Cited by 19
“…etc., while physiological signals include electroencephalogram (EEG) (Namazi et al., 2020; Song et al., 2020), electrocardiogram (ECG) (Al-Sheikh et al., 2019; Nguyen et al., 2019; Fang et al., 2020; Sarkar and Etemad, 2021) and electromyography (EMG) (Hossen et al., 2020; Kulke et al., 2020), etc.”
BackgroundMachine learning aided classification of tremor in multiple sclerosis
Hossen, A., Anwar, A. R., Koirala, N., Ding, H., Budker, D., Wickenbrock, A., Heute, U., Deuschl, G., Groppa, S., & Muthuraman, M. (2022) · EBioMedicine · doi:10.1016/j.ebiom.2022.104152 · Cited by 15
“41,47 For the classification, the recorded data were divided into training and testing sets with each subject randomly assigned to a set.”
Self-citationLiu, S., Yuan, H., Liu, J., Lin, H., Yang, C., & Cai, X. (2021) · Technology and Health Care · doi:10.3233/thc-213205 · Cited by 12
“With the growing interest in applications of wearable devices, accelerometers and gyroscopes have been used in the evaluation of tremor in PD [15–19].”
Metadata
- Authors
- Hossen, A., Deuschl, G., Groppa, S., Heute, U., & Muthuraman, M.
- Affiliations
- Sultan Qaboos University (OM)
- Christian-Albrechts-Universität zu Kiel (DE)
- Johannes Gutenberg University Mainz (DE)
- Corresponding author
- Hossen, A.
- Venue
- Technology and Health Care
- Publisher
- SAGE Publications
- Published
- 2020-09-18
- Volume
- 28
- Issue
- 5
- Pages
- 461-476
- ISSN
- 0928-7329 (ISSN-L)
- 1878-7401
- OpenAlex
- W3016115762
- Cited by
- 18
- References
- 39
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 3 · 2023: 2 · 2022: 3 · 2021: 4
- FWCI
- 0.71
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Technology and Health Care (publishedVersion)
- PubMed (publishedVersion)
- OPUS (Augsburg University) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- physiological tremor, pathological tremor, essential tremor, Parkinson's disease, tremor classification, accelerometer signals, surface electromyography, wavelet decomposition, power spectral density
- MeSH terms
- Electromyography, Humans, Parkinson Disease, Tremor, Essential Tremor, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.