The DOI matches its Crossref record.
In vivo high resolution 3D-QCT of the human forearm
Abstract
In vivo examinations of bone microarchitecture have become available recently through high resolution computed tomography (3D-QCT) and magnetic resonance imaging. The spatial resolution of the resulting images, however, is not sufficient to depict individual trabeculae in their true shape. Nevertheless, structural indices such as relative bone volume, trabecular number, mean thickness and mean separation can be extracted with the help of a ridge detection algorithm. Precision of the procedure is of the order of 1%, accuracy is ascertained using a micro-CT based calibration. In this work we report first results of time serial examinations. Eighteen healthy postmenopausal women (no HRT) were measured at months 0, 6, and 12, and the temporal changes were analyzed. Examination site was the distal radius. The above mentioned structural indices, the average densities and the thickness of the cortical shell were determined. Of the 18 women 6 showed no significant bone loss of any kind, 5 lost primarily cancellous bone, 4 lost primarily cortical bone, and 3 had a substantial loss of cortical as well as cancellous bone. We conclude that even in a homogenous group such as postmenopausal women, there are considerable differences in the reason why bone is weakened and that high resolution 3D-QCT allows to differentiate between various types of bone loss.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nilsson, A. G., Sundh, D., Bäckhed, F., & Lorentzon, M. (2018) · Journal of Internal Medicine · doi:10.1111/joim.12805 · Cited by 323
Nilsson, A. G., Sundh, D., Johansson, L., Nilsson, M., Mellström, D., Rudäng, R., Zoulakis, M., Wallander, M., Darelid, A., & Lorentzon, M. (2017) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.3057 · Cited by 217
Shanbhogue, V. V., Hansen, S., Frost, M., Jørgensen, N. R., Hermann, A. P., Henriksen, J. E., & Brixen, K. (2015) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2573 · Cited by 183
Nishiyama, K. K., Macdonald, H. M., Moore, S. A., Fung, T., Boyd, S. K., & McKay, H. A. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.552 · Cited by 122
Madeira, M., Neto, L. V., de Paula Paranhos Neto, F., Barbosa Lima, I. C., Carvalho de Mendonça, L. M., Gadelha, M. R., & Fleiuss de Farias, M. L. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-4073 · Cited by 114
Metadata
- Authors
- Laib, A., Häuselmann, H. J., & Rüegsegger, P.
- Venue
- Technology and Health Care
- Publisher
- SAGE Publications
- Published
- 1998-12-01
- Volume
- 6
- Issue
- 5-6
- Pages
- 329-337
- ISSN
- 0928-7329 (ISSN-L)
- 1878-7401
- OpenAlex
- W1702563725
- Cited by
- 454
- References
- 0
- FWCI
- 5.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo high resolution 3D-QCT of the human forearm. https://app.cochat.ai/papers/10.3233/thc-1998-65-606
- The paper
- Laib, A., Häuselmann, H. J., & Rüegsegger, P. (1998). In vivo high resolution 3D-QCT of the human forearm. Technology and Health Care. https://doi.org/10.3233/thc-1998-65-606
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.