Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 454

The DOI matches its Crossref record.

In vivo high resolution 3D-QCT of the human forearm

Laib, Andres, Häuselmann, Hans Jörg, Rüegsegger, Peter·1998·Technology and Health Care

Abstract

In vivo examinations of bone microarchitecture have become available recently through high resolution computed tomography (3D-QCT) and magnetic resonance imaging. The spatial resolution of the resulting images, however, is not sufficient to depict individual trabeculae in their true shape. Nevertheless, structural indices such as relative bone volume, trabecular number, mean thickness and mean separation can be extracted with the help of a ridge detection algorithm. Precision of the procedure is of the order of 1%, accuracy is ascertained using a micro-CT based calibration. In this work we report first results of time serial examinations. Eighteen healthy postmenopausal women (no HRT) were measured at months 0, 6, and 12, and the temporal changes were analyzed. Examination site was the distal radius. The above mentioned structural indices, the average densities and the thickness of the cortical shell were determined. Of the 18 women 6 showed no significant bone loss of any kind, 5 lost primarily cancellous bone, 4 lost primarily cortical bone, and 3 had a substantial loss of cortical as well as cancellous bone. We conclude that even in a homogenous group such as postmenopausal women, there are considerable differences in the reason why bone is weakened and that high resolution 3D-QCT allows to differentiate between various types of bone loss.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3233/thc-1998-65-606

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Laib, A., Häuselmann, H. J., & Rüegsegger, P.
Venue
Technology and Health Care
Published
1998-12-01
Volume
6
Issue
5-6
Pages
329-337
ISSN
  • 0928-7329 (ISSN-L)
  • 1878-7401
OpenAlex
W1702563725
Cited by
454
References
0
FWCI
5.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.