Estimating orientation with gyroscopes and accelerometers
The DOI matches its Crossref record.
Abstract
Many systems for recording human movement need some reference from beacons near the subject, such as video cameras. Our goal is to measure human kinematics with sensors that are placed on the segments of interest. This way, experiments in which human movement is recorded are not restricted to a lab. Our inertial sensor-unit consists of a little box with three miniature gyroscopes (Murata ENC05E) and three linear accelerometers (AD xl05) that measure 3D angular velocity and linear acceleration, respectively. Both the gyroscope and accelerometer signals contain information about the orientation of the sensor. The sensor orientation can be obtained by integration of the angular velocity signals obtained from the gyroscopes [1]. This operation introduces drift in the estimated orientation. Accelerometers do not only measure the acceleration of the sensor, but also the gravitational vector. This gravitational component not only has a bigger magnitude for many human movements but also always points downwards. This knowledge can be used to make an estimation of the tilt. The tilt is the angle between the sensor axes and the vertical. This tilt estimation is not very precise but does not suffer from drift. The abstract describes a way to fuse both sensors (gyroscopes and accelerometers) to obtain an estimate of the orientation that is both accurate and is limited in integration drift.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sensor networks for medical care
Shnayder, V., Chen, B.-R., Lorincz, K., Jones, T. R. F. F., & Welsh, M. (2005) · Proceedings of the 3rd international conference on Embedded networked sensor systems · doi:10.1145/1098918.1098979 · Cited by 720
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655
Self-citationRoetenberg, D., Luinge, H. J., Baten, C. T. M., & Veltink, P. H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847353 · Cited by 588
Self-citationYun, X., & Bachmann, E. R. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2006.886270 · Cited by 569
Advances in wearable technology and applications in physical medicine and rehabilitation
Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-2 · Cited by 385
Metadata
- Authors
- Luinge, H. J., Veltink, P. H., & Baten, C. T. M.
- Venue
- Technology and Health Care
- Publisher
- SAGE Publications
- Published
- 1999-12-01
- Volume
- 7
- Issue
- 6
- Pages
- 455-459
- ISSN
- 0928-7329 (ISSN-L)
- 1878-7401
- OpenAlex
- W1502027824
- Cited by
- 103
- References
- 0
- FWCI
- 12.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimating orientation with gyroscopes and accelerometers. https://app.cochat.ai/papers/10.3233/thc-1999-7612
- The paper
- Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (1999). Estimating orientation with gyroscopes and accelerometers. Technology and Health Care. https://doi.org/10.3233/thc-1999-7612
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.