Estimating orientation with gyroscopes and accelerometers
The DOI matches its Crossref record.
Abstract
Many systems for recording human movement need some reference from beacons near the subject, such as video cameras. Our goal is to measure human kinematics with sensors that are placed on the segments of interest. This way, experiments in which human movement is recorded are not restricted to a lab. Our inertial sensor-unit consists of a little box with three miniature gyroscopes (Murata ENC05E) and three linear accelerometers (AD xl05) that measure 3D angular velocity and linear acceleration, respectively. Both the gyroscope and accelerometer signals contain information about the orientation of the sensor. The sensor orientation can be obtained by integration of the angular velocity signals obtained from the gyroscopes [1]. This operation introduces drift in the estimated orientation. Accelerometers do not only measure the acceleration of the sensor, but also the gravitational vector. This gravitational component not only has a bigger magnitude for many human movements but also always points downwards. This knowledge can be used to make an estimation of the tilt. The tilt is the angle between the sensor axes and the vertical. This tilt estimation is not very precise but does not suffer from drift. The abstract describes a way to fuse both sensors (gyroscopes and accelerometers) to obtain an estimate of the orientation that is both accurate and is limited in integration drift.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sensor networks for medical care
Shnayder, V., Chen, B.-R., Lorincz, K., Jones, T. R. F. F., & Welsh, M. (2005) · Proceedings of the 3rd international conference on Embedded networked sensor systems · doi:10.1145/1098918.1098979 · Cited by 720
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655
Self-citationRoetenberg, D., Luinge, H. J., Baten, C. T. M., & Veltink, P. H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847353 · Cited by 588
Self-citationYun, X., & Bachmann, E. R. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2006.886270 · Cited by 569
Advances in wearable technology and applications in physical medicine and rehabilitation
Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-2 · Cited by 385
Jasiewicz, J. M., Allum, J. H. J., Middleton, J. W., Barriskill, A., Condie, P., Purcell, B., & Li, R. C. T. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.12.017 · Cited by 371
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369
A review of portable FES-based neural orthoses for the correction of drop foot
Lyons, G. M., Sinkjaer, T., Burridge, J. H., & Wilcox, D. J. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806832 · Cited by 277
Shoulder and Elbow Joint Angle Tracking With Inertial Sensors
El-Gohary, M., & McNames, J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2208750 · Cited by 264
Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review
Wong, W. Y., Wong, M. S., & Lo, K. H. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600983949 · Cited by 193
“Luinge et al. (1999) suggested a method to solve the problem of output drift when using gyroscope.”
MethodDetecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes
Williamson, R., & Andrews, B. J. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345283 · Cited by 185
Gait analysis using gravitational acceleration measured by wearable sensors
Takeda, R., Tadano, S., Todoh, M., Morikawa, M., Nakayasu, M., & Yoshinari, S. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.10.027 · Cited by 128
“2 Frequency analysis Acceleration data collected by the acceleration sensors during motion has three major components: translational acceleration, gravitational acceleration, and external noise (Luinge et al., 1999).”
BackgroundInfluentialAccuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion
Godwin, A., Agnew, M., & Stevenson, J. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.4000109 · Cited by 107
Evaluation of a hybrid system for three-dimensional measurement of trunk posture in motion
Plamondon, A., Delisle, A., Larue, C., Brouillette, D., McFadden, D., Desjardins, P., & Larivière, C. (2007) · Applied Ergonomics · doi:10.1016/j.apergo.2006.12.006 · Cited by 102
Schall, M. C., Fethke, N. B., Chen, H., Oyama, S., & Douphrate, D. I. (2016) · Ergonomics · doi:10.1080/00140139.2015.1079335 · Cited by 96
Metadata
- Authors
- Luinge, H. J., Veltink, P. H., & Baten, C. T. M.
- Venue
- Technology and Health Care
- Publisher
- SAGE Publications
- Published
- 1999-12-01
- Volume
- 7
- Issue
- 6
- Pages
- 455-459
- ISSN
- 0928-7329 (ISSN-L)
- 1878-7401
- OpenAlex
- W1502027824
- Cited by
- 103
- References
- 0
- FWCI
- 12.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.