Aptamers: Problems, Solutions and Prospects
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Aptamers are short single-stranded oligonucleotides that are capable of binding various molecules with high affinity and specificity. When the technology of aptamer selection was developed almost a quarter of a century ago, a suggestion was immediately put forward that it might be a revolutionary start into solving many problems associated with diagnostics and the therapy of diseases. However, multiple attempts to use aptamers in practice, although sometimes successful, have been generally much less efficient than had been expected initially. This review is mostly devoted not to the successful use of aptamers but to the problems impeding the widespread application of aptamers in diagnostics and therapy, as well as to approaches that could considerably expand the range of aptamer application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levin, A. A. (1999) · Biochimica et Biophysica Acta (BBA) - Gene Structure and Expression · doi:10.1016/s0167-4781(99)00140-2 · Cited by 438
Closing the circle: replicating RNA with RNA.
Cheng, L. K. L., & Unrau, P. J. (2010) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a002204 · Cited by 58
Design of Polyphosphoester‐DNA Nanoparticles for Non‐Viral Gene Delivery
Mao, H., & Leong, K. W. (2005) · Advances in genetics · doi:10.1016/s0065-2660(05)53011-6 · Cited by 41
Cited by
Electrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Wang, T., Chen, C., Larcher, L. M., Barrero, R. A., & Veedu, R. N. (2019) · Biotechnology Advances · doi:10.1016/j.biotechadv.2018.11.001 · Cited by 525
The role of CD133 in cancer: a concise review
Glumac, P. M., & LeBeau, A. M. (2018) · Clinical and Translational Medicine · doi:10.1186/s40169-018-0198-1 · Cited by 400
Synthesis, Assembly, and Applications of Hybrid Nanostructures for Biosensing
Zhang, S., Geryak, R., Geldmeier, J., Kim, S., & Tsukruk, V. V. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00088 · Cited by 340
Triple-Negative Breast Cancer: A Review of Conventional and Advanced Therapeutic Strategies
Medina, M. A., Oza, G., Sharma, A., Arriaga, L. G., Hernández Hernández, J. M., Rotello, V. M., & Ramirez, J. T. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17062078 · Cited by 333
RNA interference-based therapy and its delivery systems
Chen, X., Mangala, L. S., Rodriguez-Aguayo, C., Kong, X., Lopez-Berestein, G., & Sood, A. K. (2018) · Cancer and Metastasis Reviews · doi:10.1007/s10555-017-9717-6 · Cited by 329
Fluorescent Sensors for the Detection of Heavy Metal Ions in Aqueous Media
De Acha, N., Elosúa, C., Corres, J., & Arregui, F. (2019) · Sensors · doi:10.3390/s19030599 · Cited by 294
Bajracharya, R., Song, J. G., Patil, B. R., Lee, S. H., Noh, H.-M., Kim, D.-H., Kim, G.-L., Seo, S.-H., Park, J.-W., Jeong, S. H., et al. (2022) · Drug Delivery · doi:10.1080/10717544.2022.2089296 · Cited by 246
“Degradation during blood circulation also limits the application of aptamers (Lakhin et al., 2013).”
BackgroundCurrent Perspectives on Aptamers as Diagnostic Tools and Therapeutic Agents
Kumar Kulabhusan, P., Hussain, B., & Yüce, M. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12070646 · Cited by 245
“This is due to the post-translational modifications inside the eukaryotic cells, and hence the proteins are not able to bind to the aptamers with the same affinity [109].”
BackgroundRecent Advances in the Detection of Neurotransmitters
Si, B., & Song, E. (2018) · Chemosensors · doi:10.3390/chemosensors6010001 · Cited by 219
“Through iterative selection processes such as SELEX [75,76], the aptamer sequences are carefully chosen to optimize the binding efficiency [77].”
MethodAptamers 101: aptamer discovery and in vitro applications in biosensors and separations
Yang, L. F., Ling, M., Kacherovsky, N., & Pun, S. H. (2023) · Chemical Science · doi:10.1039/d3sc00439b · Cited by 215
In vitro selection of aptamers and their applications
DeRosa, M. C., Lin, A., Mallikaratchy, P., McConnell, E. M., McKeague, M., Patel, R., & Shigdar, S. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00238-7 · Cited by 183
Ali, M. H., Elsherbiny, M. E., & Emara, M. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20102511 · Cited by 181
“For example, instead of endonuclease-sensitive RNA aptamers (D-form), researchers select endonuclease-resistant RNA aptamers (L-form) that result from binding to the mirror-image of the intended target molecule [173–176].”
BackgroundInfluentialMicrofluidic devices for sample preparation and rapid detection of foodborne pathogens
Kant, K., Shahbazi, M.-A., Dave, V. P., Ngo, T. A., Chidambara, V. A., Than, L. Q., Bang, D. D., & Wolff, A. (2018) · Biotechnology Advances · doi:10.1016/j.biotechadv.2018.03.002 · Cited by 179
“Therefore, attention to all these restrictions is essential for the development of an efficient detecting device (Lakhin et al., 2013).”
BackgroundRecent Progress and Opportunities for Nucleic Acid Aptamers
Byun, J. (2021) · Life · doi:10.3390/life11030193 · Cited by 177
“As a consequence, the protocol developed for one aptamer cannot be applied for other aptamers [86].”
BackgroundCurrent and Prospective Protein Biomarkers of Lung Cancer
Zamay, T., Zamay, G., Kolovskaya, O., Zukov, R., Petrova, M., Gargaun, A., Berezovski, M., & Kichkailo, A. (2017) · Cancers · doi:10.3390/cancers9110155 · Cited by 174
“Despite the promising qualities aptamers possess for diagnostic and therapeutic purposes, their widespread application is still limited due to problems and pitfalls that currently plague the technology [85,86].”
BackgroundTumor target amplification: Implications for nano drug delivery systems
Seidi, K., Neubauer, H. A., Moriggl, R., Jahanban-Esfahlan, R., & Javaheri, T. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2018.02.020 · Cited by 145
Klinghammer, S., Voitsekhivska, T., Licciardello, N., Kim, K., Baek, C.-K., Cho, H., Wolter, K.-J., Kirschbaum, C., Baraban, L., & Cuniberti, G. (2020) · ACS Sensors · doi:10.1021/acssensors.0c02267 · Cited by 62
Biofunctionalization of Multiplexed Silicon Photonic Biosensors
Puumala, L. S., Grist, S. M., Morales, J. M., Bickford, J. R., Chrostowski, L., Shekhar, S., & Cheung, K. C. (2022) · Biosensors · doi:10.3390/bios13010053 · Cited by 55
Metadata
- Authors
- Lakhin, A. V., Tarantul, V. Z., & Gening, L. V.
- Venue
- Acta Naturae
- Publisher
- Acta Naturae Ltd
- Published
- 2013-12-15
- Volume
- 5
- Issue
- 4
- Pages
- 34-43
- ISSN
- 2075-8243 (ISSN-L)
- 2075-8251
- OpenAlex
- W4296766525
- Cited by
- 577
- References
- 3
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.