OBJECTIVES: To estimate the diagnostic accuracy of non-invasive tests for proximal deep vein thrombosis (DVT) and isolated calf DVT, in patients with clinically suspected DVT or high-risk asymptomatic patients, and identify factors associated with variation in diagnostic performance. Also to identify practical diagnostic algorithms for DVT, and estimate the diagnostic accuracy, clinical effectiveness and cost-effectiveness of each. DATA SOURCES: Electronic databases (to April 2004). A postal survey of hospitals in the UK. REVIEW METHODS: Selected studies were assessed against validated criteria. A postal survey of hospitals in the UK was undertaken to describe current practice and availability of tests, and identify additional diagnostic algorithms. Pooled estimates of sensitivity, specificity and likelihood ratios were obtained for each test using random effects meta-analysis. The effect of study-level covariates was explored using random effects metaregression. A decision-analytic model was used to combine estimates from the meta-analysis and estimate the diagnostic performance of each algorithm in a theoretical population of outpatients with suspected DVT. The net benefit of using each algorithm was estimated from a health service perspective, using cost--utility analysis, assuming thresholds of willingness to pay of pound 20,000 and pound 30,000 per quality-adjusted life-year (QALY). The model was analysed probabilistically and cost-effectiveness acceptability curves were generated to reflect uncertainty in estimated cost-effectiveness. RESULTS: Individual clinical features are of limited diagnostic value, with most likelihood ratios being close to 1. Wells clinical probability score stratifies proximal, but not distal, DVT into high-, intermediate- and low-risk categories. Unstructured clinical assessment by experienced clinicians may have similar performance to Wells score. In patients with clinically suspected DVT, D-dimer has 91% sensitivity and 55% specificity for DVT, although performance varies substantially between assays and populations. D-dimer specificity is dependent on pretest clinical probability, being higher in patients with a low clinical probability of DVT. Plethysmography and rheography techniques have modest sensitivity for proximal DVT, poor sensitivity for distal DVT, and modest specificity. Ultrasound has 94% sensitivity for proximal DVT, 64% sensitivity for distal DVT and 94% specificity. Computed tomography scanning has 95% sensitivity for all DVT (proximal and distal combined) and 97% specificity. Magnetic resonance imaging has 92% sensitivity for all DVT and 95% specificity. The diagnostic performance of all tests is worse in asymptomatic patients. The most cost-effective algorithm discharged patients with a low Wells score and negative D-dimer without further testing, and then used plethysmography alongside ultrasound, with venography in selected cases, to diagnose the remaining patients. However, the cost-effectiveness of this algorithm was dependent on assumptions of test independence being met and the ability to provide plethysmography at relatively low cost. Availability of plethysmography and venography is currently limited at most UK hospitals, so implementation would involve considerable reorganisation of services. Two algorithms were identified that offered high net benefit and would be feasible in most hospitals without substantial reorganisation of services. Both involved using a combination of Wells score, D-dimer and above-knee ultrasound. For thresholds of willingness to pay of pound 10,000 or pound 20,000 per QALY the optimal strategy involved discharging patients with a low or intermediate Wells score and negative D-dimer, ultrasound for those with a high score or positive D-dimer, and repeat scanning for those with positive D-dimer and a high Wells score, but negative initial scan. For thresholds of pound 30,000 or more a similar strategy, but involving repeat ultrasound for all those with a negative initial scan, was optimal. CONCLUSIONS: Diagnostic algorithms based on a combination of Wells score, D-dimer and ultrasound (with repeat if negative) are feasible at most UK hospitals and are among the most cost-effective. Use of repeat scanning depends on the threshold for willingness to pay for health gain. Further diagnostic testing for patients with a low Wells score and negative D-dimer is unlikely to represent a cost-effective use of resources. Recommendations for research include the evaluation of the costs and outcomes of using the optimal diagnostic algorithms in routine practice, the development and evaluation of algorithms appropriate for specific groups of patients with suspected DVT, such as intravenous drug abusers, pregnant patients and those with previous DVT, the evaluation of the role of plethysmography: interaction with other diagnostic tests, outcome of low-risk patients with negative plethysmography and measurement of the costs of providing pl

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta10150

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 180

Metadata

Authors
Goodacre, S., Sampson, F., Stevenson, M., Wailoo, A., Sutton, A., Thomas, S., Locker, T., & Ryan, A.
Venue
Health Technology Assessment
Published
2006-05
Volume
10
Issue
15
Pages
1-168, iii
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W2049503062
Cited by
180
References
0
FWCI
9.40
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of the clinical and cost-effectiveness of non-invasive diagnostic testing strategies for deep vein thrombosis. https://app.cochat.ai/papers/10.3310/hta10150
The paper
Goodacre, S., Sampson, F., Stevenson, M., Wailoo, A., Sutton, A., Thomas, S., Locker, T., & Ryan, A. (2006). Measurement of the clinical and cost-effectiveness of non-invasive diagnostic testing strategies for deep vein thrombosis. Health Technology Assessment. https://doi.org/10.3310/hta10150

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.