The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Systematic review of the clinical effectiveness and cost-effectiveness of 64-slice or higher computed tomography angiography as an alternative to invasive coronary angiography in the investigation of coronary artery disease
Open accessAbstract
OBJECTIVES: To assess the clinical effectiveness and cost-effectiveness, in different patient groups, of the use of 64-slice or higher computed tomography (CT) angiography, instead of invasive coronary angiography (CA), for diagnosing people with suspected coronary artery disease (CAD) and assessing people with known CAD. DATA SOURCES: Electronic databases were searched from 2002 to December 2006. REVIEW METHODS: Included studies were tabulated and sensitivity, specificity, positive and negative predictive values calculated. Meta-analysis models were fitted using hierarchical summary receiver operating characteristic curves. Summary sensitivity, specificity, positive and negative likelihood ratios and diagnostic odds ratios for each model were reported as a median and 95% credible interval (CrI). Searches were also carried out for studies on the cost-effectiveness of 64-slice CT in the assessment of CAD. RESULTS: The diagnostic accuracy and prognostic studies enrolled over 2500 and 1700 people, respectively. The overall quality of the studies was reasonably good. In the pooled estimates, 64-slice CT angiography was highly sensitive (99%, 95% CrI 97 to 99%) for patient-based detection of significant CAD (defined as 50% or more stenosis), while across studies the negative predictive value (NPV) was very high (median 100%, range 86 to 100%). In segment-level analysis compared with patient-based detection, sensitivity was lower (90%, 95% CrI 85 to 94%, versus 99%, 95% CrI 97 to 99%) and specificity higher (97%, 95% CrI 95 to 98%, versus 89%, 95% CrI 83 to 94%), while across studies the median NPV was similar (99%, range 95 to 100%, versus 100%, range 86 to 100%). At individual coronary artery level the pooled estimates for sensitivity ranged from 85% for the left circumflex (LCX) artery to 95% for the left main artery, specificity ranged from 96% for both the left anterior descending (LAD) artery and LCX to 100% for the left main artery, while across studies the positive predictive value (PPV) ranged from 81% for the LCX to 100% for the left main artery and NPV was very high, ranging from 98% for the LAD (range 95 to 100%), LCX (range 93 to 100%) and right coronary artery (RCA) (range 94 to 100%) to 100% for the left main artery. The pooled estimates for bypass graft analysis were 99% (95% CrI 95 to 100%) sensitivity, 96% (95% CrI 86 to 99%) specificity, with median PPV and NPV values across studies of 93% (range 90 to 95%) and 99% (range 98 to 100%), respectively. This compares with, for stent analysis, a pooled sensitivity of 89% (95% CrI 68 to 97%), specificity 94% (95% CrI 83 to 98%), and median PPV and NPV values across studies of 77% (range 33 to 100%) and 96% (range 71 to 100%), respectively. Sixty-four-slice CT is almost as good as invasive CA in terms of detecting true positives. However, it is somewhat poorer in its rate of false positives. It seems likely that diagnostic strategies involving 64-slice CT will still require invasive CA for CT test positives, partly to identify CT false positives, but also because CA provides other information that CT currently does not, notably details of insertion site and distal run-off for possible coronary artery bypass graft (CABG). The high sensitivity of 64-slice CT avoids the costs of unnecessary CA in those referred for investigation but who do not have CAD. Given the possible, although small, associated death rate, avoiding these unnecessary CAs through the use of 64-slice CT may also confer a small immediate survival advantage. This in itself may be sufficient to outweigh the very marginally inferior rates of detection of true positives by strategies involving 64-slice CT. The avoidance of unnecessary CA through the use of 64-slice CT also appears likely to result in overall cost savings in the diagnostic pathway. Only if both the cost of CA is relatively low and the prevalence of CAD in the presenting population is relatively high (so that most patients will go on to CA) will the use of 64-slice CT be likely to result in a higher overall diagnostic cost per patient. CONCLUSIONS: The main value of 64-slice CT may at present be to rule out significant CAD. It is unlikely to replace CA in assessment for revascularisation of patients, particularly as angiography and angioplasty are often done on the same occasion. Further research is needed into the marginal advantages and costs of 256-slice machines compared with 64-slice CT, the usefulness of 64-slice CT in people with suspected acute coronary syndrome, the potential of multislice computed tomography to examine plaque morphology, the role of CT in identifying patients suitable for CABG, and the concerns raised about repetitive use, or use of 64-slice or higher CT angiography in younger individuals or women of childbearing age.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
Practical Statistics for Medical Research.
Walter, S. D., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,668
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
A hierarchical regression approach to meta‐analysis of diagnostic test accuracy evaluations
Rutter, C. M., & Gatsonis, C. A. (2001) · Statistics in Medicine · doi:10.1002/sim.942 · Cited by 1,505
Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography
Raff, G. L., Gallagher, M. J., O’Neill, W. W., & Goldstein, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.056 · Cited by 1,472
Systematic reviews of evaluations of diagnostic and screening tests
Deeks, J. J. (2001) · BMJ · doi:10.1136/bmj.323.7305.157 · Cited by 1,340
The Efficacy of Diagnostic Imaging
Fryback, D. G., & Thornbury, J. R. (1991) · Medical Decision Making · doi:10.1177/0272989x9101100203 · Cited by 1,291
Hendel, R. C., Patel, M. R., Kramer, C. M., Poon, M., Hendel, R. C., Carr, J. C., Gerstad, N. A., Gillam, L. D., Hodgson, J. M., Kim, R. J., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.003 · Cited by 1,288
Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography
Leber, A. W., Knez, A., von Ziegler, F., Becker, A., Nikolaou, K., Paul, S., Wintersperger, B., Reiser, M., Becker, C. R., Steinbeck, G., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.071 · Cited by 1,109
Mollet, N. R., Cademartiri, F., van Mieghem, C. A. G., Runza, G., McFadden, E. P., Baks, T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2005) · Circulation · doi:10.1161/circulationaha.105.533471 · Cited by 1,018
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Hausleiter, J., Meyer, T., Hadamitzky, M., Huber, E., Zankl, M., Martinoff, S., Kastrati, A., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.602490 · Cited by 705
Noninvasive Coronary Angiography With Multislice Computed Tomography
Hoffmann, M. H. K. (2005) · JAMA · doi:10.1001/jama.293.20.2471 · Cited by 507
Schuijf, J. D., Wijns, W., Jukema, J. W., Atsma, D. E., de Roos, A., Lamb, H. J., Stokkel, M. P. M., Dibbets-Schneider, P., Decramer, I., De Bondt, P., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.05.080 · Cited by 479
Hamon, M., Biondi-Zoccai, G. G. L., Malagutti, P., Agostoni, P., Morello, R., Valgimigli, M., & Hamon, M. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.028 · Cited by 460
Cost-Effectiveness of Alternative Test Strategies for the Diagnosis of Coronary Artery Disease
Garber, A. M., & Solomon, N. A. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-9-199905040-00003 · Cited by 274
Coles, D. R., Smail, M. A., Negus, I. S., Wilde, P., Oberhoff, M., Karsch, K. R., & Baumbach, A. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.078 · Cited by 265
Schuijf, J. D., Bax, J. J., Shaw, L. J., de Roos, A., Lamb, H. J., van der Wall, E. E., & Wijns, W. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.03.022 · Cited by 255
Kopp, A. (2002) · European Heart Journal · doi:10.1016/s0195-668x(02)93264-1 · Cited by 252
Meijboom, W. B., Mollet, N. R., Van Mieghem, C. A. G., Kluin, J., Weustink, A. C., Pugliese, F., Vourvouri, E., Cademartiri, F., Bogers, A. J. J. C., Krestin, G. P., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.06.054 · Cited by 249
Leber, A. W., Knez, A., White, C. W., Becker, A., von Ziegler, F., Muehling, O., Becker, C., Reiser, M., Steinbeck, G., & Boekstegers, P. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)03411-2 · Cited by 242
Schuijf, J. D., Pundziute, G., Jukema, J. W., Lamb, H. J., van der Hoeven, B. L., de Roos, A., van der Wall, E. E., & Bax, J. J. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.01.092 · Cited by 232
Kuettner, A., Kopp, A. F., Schroeder, S., Rieger, T., Brunn, J., Meisner, C., Heuschmid, M., Trabold, T., Burgstahler, C., Martensen, J., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.05.015 · Cited by 228
A Comparison of Approximate Interval Estimators for the Bernoulli Parameter
Leemis, L. M., & Trivedi, K. S. (1996) · The American Statistician · doi:10.1080/00031305.1996.10473544 · Cited by 217
Wintersperger, B. J., Nikolaou, K., von Ziegler, F., Johnson, T. R. C., Rist, C., Leber, A. W., Flohr, T. G., Knez, A., Reiser, M. F., & Becker, C. R. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000202639.99949.c6 · Cited by 194
Cost-Effectiveness of Diagnostic Strategies for Patients with Chest Pain
Kuntz, K. M., Fleischmann, K. E., Hunink, M. G. M., & Douglas, P. S. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-9-199905040-00002 · Cited by 192
(2007) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2007.05.034 · Cited by 185
Economics of Myocardial Perfusion Imaging in Europe—the EMPIRE study
Underwood, S. (1999) · European Heart Journal · doi:10.1053/euhj.1998.1196 · Cited by 181
ECG-Gated 64-MDCT Angiography in the Differential Diagnosis of Acute Chest Pain
Johnson, T. R. C., Nikolaou, K., Wintersperger, B. J., Knez, A., Boekstegers, P., Reiser, M. F., & Becker, C. R. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.1153 · Cited by 158
Multidetector Computed Tomography for the Diagnosis of Coronary Artery Disease: A Systematic Review
Stein, P. D., Beemath, A., Kayali, F., Skaf, E., Sánchez, J., & Olson, R. E. (2006) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.06.071 · Cited by 154
Kefer, J., Coche, E., Legros, G., Pasquet, A., Grandin, C. B. G., BEERS, B. E. V., Vanoverschelde, J., & Gerber, B. L. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.057 · Cited by 144
Berman, D. S., Hachamovitch, R., Shaw, L. J., Friedman, J. D., Hayes, S. W., Thomson, L., Fieno, D. S., Germano, G., Wong, N. D., Kang, X., et al. (2006) · PubMed · Cited by 139
Sun, Z., & Jiang, W. J. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.06.009 · Cited by 138
Hartwell, D., Colquitt, J. L., Loveman, E., Clegg, A. P., Brodin, H., Waugh, N., Royle, P., Davidson, P., Vale, L. D., & MacKenzie, L. (2005) · Health Technology Assessment · doi:10.3310/hta9170 · Cited by 132
Self-citationGhostine, S., Caussin, C., Daoud, B., Habis, M., Perrier, E., Pesenti-Rossi, D., Sigal-Cinqualbre, A. B., Angel, C.-Y., Lancelin, B., Capderou, A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.04.103 · Cited by 127
Boland, A., Dundar, Y., Bagust, A., Haycox, A. R., Hill, R. A., Mujica-Mota, R. E., Walley, T., & Dickson, R. (2003) · Health Technology Assessment · doi:10.3310/hta7150 · Cited by 127
Mowatt, G., Vale, L. D., Brazzelli, M. G., Hernández, R. A., Murray, A. D., Scott, N., Fraser, C. M., McKenzie, L., Gemmell, H. G., Hillis, G. S., et al. (2004) · Health Technology Assessment · doi:10.3310/hta8300 · Cited by 120
Self-citationvan Mieghem, C. A. G., McFadden, E. P., de Feyter, P. J., Bruining, N., Schaar, J. A., Mollet, N. R., Cademartiri, F., Goedhart, D. M., de Winter, S., Rodríguez-Granillo, G. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.075 · Cited by 112
ACR Practice Guideline for the Performance and Interpretation of Cardiac Computed Tomography (CT)
Jacobs, J. E., Boxt, L. M., Desjardins, B., Fishman, E. K., Larson, P. A., & Schoepf, J. (2006) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2006.06.006 · Cited by 104
Sato, Y., Matsumoto, N., Ichikawa, M., Kunimasa, T., Iida, K., Yoda, S., Takayama, T., Uchiyama, T., Saito, S., Nagao, K., et al. (2005) · Circulation Journal · doi:10.1253/circj.69.1047 · Cited by 92
Reply: Comparison of 64-Slice CT with Gated SPECT for Evaluation of Left Ventricular Function
Kaufmann, P. A., & Gaemperli, O. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.037457 · Cited by 77
Howard, W. J. (2007) · Yearbook of Endocrinology · doi:10.1016/s0084-3741(08)70049-0 · Cited by 76
New imaging techniques for diagnosing coronary artery disease
Escolar, E., Weigold, G., Fuisz, A., & Weissman, N. J. (2006) · Canadian Medical Association Journal · doi:10.1503/cmaj.050925 · Cited by 75
Mitsutake, R., Niimura, H., Miura, S., Zhang, B., Iwata, A., Nishikawa, H., Kawamura, A., Kumagai, K., Shirai, K., Matsunaga, A., et al. (2006) · Circulation Journal · doi:10.1253/circj.70.1122 · Cited by 73
Waugh, N., Black, C., Walker, S., McIntyre, L., Cummins, E., & Hillis, G. S. (2006) · Health Technology Assessment · doi:10.3310/hta10390 · Cited by 70
Self-citationGershlick, A., de Belder, M., Chambers, J. B., Hackett, D., Keal, R. P., Kelion, A. D., Neubauer, S., Pennell, D. J., Rothman, M., Signy, M., et al. (2007) · Heart · doi:10.1136/hrt.2006.108779 · Cited by 67
(2006) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2006.08.008 · Cited by 64
Schuijf, J. D., Bax, J. J., Jukema, J. W., Lamb, H. J., Vliegen, H. W., Salm, L. P., Roos, A., & van der Wall, E. E. (2004) · Diabetes Care · doi:10.2337/diacare.27.12.2905 · Cited by 62
Multi-Detector Computed Tomography in Coronary Artery Bypass Graft Assessment: A Meta-Analysis
Jones, C. M., Athanasiou, T., Dunne, N., Kirby, J., Aziz, O., Haq, A., Rao, C., Constantinides, V. A., Purkayastha, S., & Darzi, A. W. (2006) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2006.08.018 · Cited by 61
Kunimasa, T., Sato, Y., Sugi, K., & Moroi, M. (2005) · Circulation Journal · doi:10.1253/circj.69.1346 · Cited by 57
Gerber, T. C., Kuzo, R. S., Lane, G. E., O’Brien, P. C., Karstaedt, N., Morin, R. L., Safford, R. E., Blackshear, J. L., & Pietan, J. H. (2003) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200301000-00012 · Cited by 54
Comparison of 64-Slice CT with Gated SPECT for Evaluation of Left Ventricular Function
Dudley, N., & Kalirai, C. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.037333 · Cited by 52
Caussin, C., Ohanessian, A., Lancelin, B., Rahal, S., Hennequin, R., Dambrin, G., Brénot, P., Angel, C.-Y., & Paul, J. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(03)00899-3 · Cited by 52
Coronary Artery Bypass Graft Surgery
Morris, C. D., Eagle, K. A., O’Rourke, R. A., & Guyton, R. A. (2008) · doi:10.1002/9781444303476.ch7 · Cited by 51
Localizing Calcifications in Cardiac CT Data Sets Using a New Vessel Segmentation Approach
Wesarg, S., Khan, M. F., & Firle, E. A. (2006) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-006-9947-6 · Cited by 49
Berry, E., Kelly, Hutton, J., Harris, Roderick, P., Boyce, Cullingworth, Gathercole, O’Connor, P., & Smith, M. A. (1999) · Health Technology Assessment · doi:10.3310/hta3180 · Cited by 43
van Mieghem, C. A. G., Bruining, N., Schaar, J. A., McFadden, E. P., Mollet, N. R., Cademartiri, F., Mastik, F., Ligthart, J. M. R., Rodríguez-Granillo, G. A., Valgimigli, M., et al. (2005) · International journal of cardiac imaging · doi:10.1007/s10554-004-7986-y · Cited by 39
Coronary anomalies by cardiac computed tomographic angiography
Budoff, M. J., Ahmed, V., Gul, K. M., Mao, S. S., & Gopal, A. (2006) · Clinical Cardiology · doi:10.1002/clc.4960291104 · Cited by 31
Noninvasive Coronary Angiography With Multislice Computed Tomography
Hoffmann, M. H. K., Shi, H., & Schmitz, B. (2005) · ACC Current Journal Review · doi:10.1016/j.accreview.2005.08.211 · Cited by 28
Kymes, S. M., Bruns, D. E., Shaw, L. J., Gillespie, K. N., & Fletcher, J. W. (2000) · Journal of Nuclear Cardiology · doi:10.1067/mnc.2000.109027 · Cited by 27
Schroeder, S., Kuettner, A., Beck, T., Kopp, A. F., Herdeg, C., Heuschmid, M., Burgstahler, C., Seipel, L., & Claussen, C. D. (2004) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.05.057 · Cited by 26
Multi-slice computed tomography in coronary artery disease
JONES, C., Athanasiou, T., Dunne, N., KIRBY, J., Attaran, S., Chow, A., Purkayastha, S., & Darzi, A. W. (2006) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2006.06.004 · Cited by 26
Multislice Computer Tomography for Detection of Coronary Artery Disease
Ropers, D. (2006) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2006.00200.x · Cited by 19
Abbara, S. (2007) · Yearbook of Diagnostic Radiology · doi:10.1016/s0098-1672(08)70245-5 · Cited by 19
van Ooijen, P. M. A., Nieman, K., de Feyter, P. J., & Oudkerk, M. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02686-3 · Cited by 12
Lawler, L. P., Horton, K. M., Scatarige, J. C., Phelps, J., Thompson, R. E., Choi, L., & Fishman, E. K. (2004) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200401000-00006 · Cited by 7
Role of computed tomography in risk assessment for coronary heart disease
Mittal, T. K., Barbir, M., & Rubens, M. B. (2006) · Postgraduate Medical Journal · doi:10.1136/pgmj.2005.043612 · Cited by 6
Contrast-enhanced cardiac computed tomographic angiography for coronary artery evaluation.
Flamm, C. R. (2005) · PubMed · Cited by 5
MSCT is better than stress perfusion imaging for detecting CAD
Cademartiri, F., & Bax, J. J. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1982-x · Cited by 3
Cited by
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,115
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000040 · Cited by 2,056
Coronary CT Angiography and 5-Year Risk of Myocardial Infarction
The SCOT-HEART Investigators (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1805971 · Cited by 1,390
Chappell, L. C., Duckworth, S., Seed, P. T., Griffin, M., Myers, J., Mackillop, L., Simpson, N., Waugh, J., Anumba, D., Kenny, L. C., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.003215 · Cited by 496
Metadata
- Authors
- Mowatt, G., Cummins, E., Waugh, N., Walker, S., Cook, J., Jia, X., Hillis, G., & Fraser, C.
- Venue
- Health Technology Assessment
- Published
- 2008-05
- Volume
- 12
- Issue
- 17
- Pages
- iii-iv, ix
- ISSN
- 1366-5278 (ISSN-L)
- 2046-4924
- OpenAlex
- W2051976691
- Cited by
- 261
- References
- 69
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.