CoChat
Cited by 274

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Cost-Effectiveness of Alternative Test Strategies for the Diagnosis of Coronary Artery Disease

Garber, Alan M., Solomon, Neil A. · 1999 · Annals of Internal Medicine

Abstract

BACKGROUND: The appropriate roles for several diagnostic tests for coronary disease are uncertain. OBJECTIVE: To evaluate the cost-effectiveness of alternative approaches to diagnosis of coronary disease. DESIGN: Meta-analysis of the accuracy of alternative diagnostic tests plus decision analysis to assess the health outcomes and costs of alternative diagnostic strategies for patients at intermediate pretest risk for coronary disease. DATA SOURCES: Studies of test accuracy that met inclusion criteria; published information on treatment effectiveness and disease prevalence. TARGET POPULATION: Men and women 45, 55, and 65 years of age with a 25% to 75% pretest risk for coronary disease. TIME HORIZON: 30 years. PERSPECTIVE: Societal. INTERVENTIONS: Diagnostic strategies were initial angiography and initial testing with one of five noninvasive tests--exercise treadmill testing, planar thallium imaging, single-photon emission computed tomography (SPECT), stress echocardiography, and positron emission tomography (PET)--followed by coronary angiography if noninvasive test results were positive. Testing was followed by observation, medical treatment, or revascularization. OUTCOME MEASURES: Life-years, quality-adjusted life-years (QALYs), costs, and costs per QALY. RESULTS OF BASE-CASE ANALYSIS: Life expectancy varied little with the initial diagnostic test; for a 55-year-old man, the best-performing test increased life expectancy by 7 more days than the worst-performing test. More sensitive tests increased QALYs more. Echocardiography improved health outcomes and reduced costs relative to stress testing and planar thallium imaging. The incremental cost-effectiveness ratio was $75,000/QALY for SPECT relative to echocardiography and was greater than $640,000 for PET relative to SPECT. Compared with SPECT, immediate angiography had an incremental cost-effectiveness ratio of $94,000/QALY. RESULTS OF SENSITIVITY ANALYSIS: Qualitative findings varied little with age, sex, pretest probability of disease, or the test indeterminancy rate. Results varied most with sensitivity to severe coronary disease. CONCLUSIONS: Echocardiography, SPECT, and immediate angiography are cost-effective alternatives to PET and other diagnostic approaches. Test selection should reflect local variation in test accuracy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.7326/0003-4819-130-9-199905040-00003

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 274

Metadata

Authors
Garber, A. M., & Solomon, N. A.
Venue
Annals of Internal Medicine
Published
1999-05-04
Volume
130
Issue
9
Pages
719-728
ISSN
  • 0003-4819 (ISSN-L)
  • 1539-3704
OpenAlex
W2038630766
Cited by
274
References
29
FWCI
11.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cost-Effectiveness of Alternative Test Strategies for the Diagnosis of Coronary Artery Disease. https://app.cochat.ai/papers/10.7326/0003-4819-130-9-199905040-00003
The paper
Garber, A. M., & Solomon, N. A. (1999). Cost-Effectiveness of Alternative Test Strategies for the Diagnosis of Coronary Artery Disease. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-130-9-199905040-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.