CoChat

Non-invasive diagnostic assessment tools for the detection of liver fibrosis in patients with suspected alcohol-related liver disease: a systematic review and economic evaluation

Open access
Stevenson, M, Lloyd-Jones, M, Morgan, MY, Wong, R · 2012 · Health Technology Assessment
Cited by 76

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Excessive alcohol consumption may lead to the development of alcohol-related liver disease (ALD). Liver biopsy may be used in patients with suspected ALD to confirm the diagnosis, exclude other or additional liver pathologies, and provide accurate staging of the degree of liver injury in order to enable the prediction of prognosis and inform treatment decisions. However, as it is an invasive procedure that carries the risk of morbidity and mortality, current UK guidance recommends that biopsy is not required to confirm the diagnosis in patients with a high clinical suspicion of ALD in whom blood tests have excluded other causes of liver disease, unless it is necessary to confirm a diagnosis of acute alcoholic hepatitis in order to inform specific treatment decisions. OBJECTIVES: To evaluate the diagnostic accuracy, cost-effectiveness, and effect on patient outcomes of four non-invasive tests for liver fibrosis [the Enhanced Liver Fibrosis (ELF™) test (Siemens Healthcare Diagnostic Inc., Tarrytown, NY, USA), FibroTest (BioPredictive, Paris, France), FibroMAX (BioPredictive, Paris, France) and transient elastography (FibroScan(®); produced by EchoSens, Paris, France and distributed in the UK by Artemis Medical Ltd, Kent, UK)] in patients suspected of having ALD. DATA SOURCES: A systematic review was undertaken to identify studies reporting the diagnostic and prognostic accuracy of the ELF test, FibroTest, FibroMAX, and FibroScan for the identification of liver fibrosis and associated conditions in patients with suspected ALD. The following databases were searched in January 2010: MEDLINE (from 1950 to January 2010), MEDLINE In-Process & Other Non-Indexed Citations (from 1950 to January 2010), EMBASE (from 1980 to January 2010), Cochrane Database of Systematic Reviews (from 1996 to January 2010), Cochrane Central Register of Controlled Trials (from 1898 to January 2010), Cochrane Methodology Register (from 1904 to January 2010), Database of Abstracts of Reviews of Effects (from 1995 to January 2010), HTA Database (from 1995 to January 2010), NHS Economic Evaluation Database (from 1995 to January 2010), Cumulative Index to Nursing and Allied Health Literature (from 1982 to January 2010), Web of Knowledge and Science Citation Index (from 1969 to January 2010). REVIEW METHODS: Study quality was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies) checklist. Owing to the heterogeneity of the studies, no formal meta-analysis was undertaken. A de novo mathematical model was constructed to estimate the incremental costs and incremental quality-adjusted life-years (QALYs) associated with alternative strategies compared with a biopsy-all strategy. The tests are assessed first as a replacement for liver biopsy, and secondly as an additional test prior to liver biopsy. Thirty-six scenarios were assessed for each non-invasive test strategy, which varied the sensitivity of biopsy, the anxiety associated with biopsy, sensitivity and specificity values and whether or not the biopsy was percutaneous or transjugular. For each scenario, threshold levels were reported where biopsying all patients was more cost-effective than the strategy for two parameters (the decreased level of abstinence associated with the strategy compared with biopsying all and the level of incidental QALY gain associated with biopsy). RESULTS: No studies were identified that specifically assessed the ELF test, although a study was identified that evaluated the diagnostic accuracy of the European Liver Fibrosis Test (essentially, the ELF test with the addition of age to the algorithm) compared with biopsy. Three studies of FibroTest, no relevant studies of FibroMax, and six studies of FibroScan assessing accuracy compared with biopsy in patients with known or suspected alcohol-related liver disease were identified. In all studies, the number of patients with suspected ALD was small, meaning that the estimated sensitivities and specificities were not robust. No conclusive estimate of the cost per QALY of each non-invasive test could be provided. Scenarios exist in which each of the strategies analysed is more cost-effective than biopsying all patients and, in contrast, scenarios exist in which each strategy is less cost-effective than biopsying all patients. LIMITATIONS: Study selection and data analysis were undertaken by one reviewer. CONCLUSIONS: No conclusive result can be provided on the most cost-effective strategy until further data are available. A large number of parameters require data; however, the following are selected as being of most importance: (1) the sensitivity and specificity of each non-invasive liver test (NILT) against biopsy at validated and pre-selected cut-off thresholds; (2) the influence of potential confounding variables such as current drinking behaviour and the degree of hepatic inflammation on the performance of NILTs; and (3) the likelihood, and magnitude, of decreases in abstinence rates

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta16040

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 76

Metadata

Authors
Stevenson, M., Lloyd-Jones, M., Morgan, M., & Wong, R.
Venue
Health Technology Assessment
Published
2012-02
Volume
16
Issue
4
Pages
1-174
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W1966367245
Cited by
76
References
11
FWCI
1.16
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.