Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 226

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Contrast-enhanced ultrasound using SonoVue® (sulphur hexafluoride microbubbles) compared with contrast-enhanced computed tomography and contrast-enhanced magnetic resonance imaging for the characterisation of focal liver lesions and detection of liver metastases: a systematic review and cost-effectiveness analysis

Open access
Westwood, M, Joore, M, Grutters, J, Redekop, K, Armstrong, N, Lee, K, Gloy, V, Raatz, H, Misso, K, Severens, J, Kleijnen, J · 2013 · Health Technol Assess

Abstract

BACKGROUND: Medical imaging techniques are important in the management of many patients with liver disease. Unenhanced ultrasound examinations sometimes identify focal abnormalities in the liver that may require further investigation, primarily to distinguish liver cancers from benign abnormalities. One important factor in selecting an imaging test is the ability to provide a rapid diagnosis. Options for additional imaging investigations include computed tomography (CT) and/or magnetic resonance imaging (MRI) and biopsy when the diagnosis remains uncertain. CT and MRI usually require referral with associated waiting time and are sometimes contraindicated. The use of contrast agents may improve the ability of ultrasound to distinguish between liver cancer and benign abnormalities and, because it can be performed at the same appointment as unenhanced ultrasound, more rapid diagnoses may be possible. OBJECTIVE: To compare the clinical effectiveness and cost-effectiveness of contrast-enhanced ultrasound (CEUS) using SonoVue(®) with that of contrast-enhanced computed tomography (CECT) and contrast-enhanced magnetic resonance imaging (CEMRI) for the assessment of adults with focal liver lesions (FLLs) in whom previous liver imaging is inconclusive. DATA SOURCES: Eight bibliographic databases including MEDLINE, EMBASE, Cochrane Database of Systematic Reviews and Database of Abstracts of Reviews of Effects were searched from 2000 to September/October 2011. Research registers and conference proceedings were also searched. REVIEW METHODS: Systematic review methods followed published guidance. Risk of bias was assessed using a modified version of the QUADAS-2 tool. Results were stratified by clinical indication for imaging (characterisation of FLLs detected on ultrasound surveillance of cirrhosis patients, detection of liver metastases, characterisation of incidentally detected FLLs, assessment of treatment response). For incidental FLLs, pooled estimates of sensitivity and specificity, with 95% CIs, were calculated using a random-effects model. For other clinical indications a narrative summary was used. The cost-effectiveness of CEUS was modelled separately for the three main clinical applications considered [characterisation of FLLs detected on ultrasound surveillance of cirrhosis patients, detection of liver metastases in patients with colorectal cancer (CRC), characterisation of incidentally detected FLLs]. RESULTS: Of the 854 references identified, 19 (describing 18 studies) were included in the review. Hand searching of conference proceedings identified a further three studies. Twenty of the 21 studies included in the systematic review were diagnostic test accuracy studies. Studies in cirrhosis patients reported varying estimates of test performance. There was no consistent evidence of a significant difference in performance between imaging modalities. It was unclear whether or not CEUS alone is adequate to rule out hepatocellular carcinoma (HCC) for FLLs of < 30 mm; one study indicated that CEUS may be better at ruling out HCC for FLLs of 11-30 mm [very small FLLs (< 10 mm) excluded]. There was no consistent evidence of a difference in test performance between imaging modalities for the detection of metastases; CEUS alone may be adequate to rule out liver metastases in colorectal cancer. In patients with incidentally detected FLLs, the pooled estimates of sensitivity for any malignancy using CEUS and CECT were 95.1% and 94.6%, respectively, and the corresponding specificity estimates were 93.8% and 93.1% respectively. One study comparing CEUS with CEMRI reported similar sensitivity and lower specificity for both modalities. In the surveillance of cirrhosis, CEUS was as effective as but £379 less costly than CECT. CEMRI was £1063 more costly than CEUS and gained 0.022 QALYs. In the detection of liver metastases from CRC, CEUS cost £1 more than CECT, and at a lifetime time horizon they yielded equal QALYs. CEMRI was dominated by CECT. In the characterisation of incidentally detected FLLs, CEUS was slightly more effective than CECT and CEMRI (by 0.0002 QALYs and 0.0026 QALYs respectively) and less costly (by £52 and £131 respectively). LIMITATIONS: There were a number of methodological issues specific to the studies included in this review. The main indication for liver imaging in the populations considered is likely to be to rule out primary liver cancer or metastases. Therefore, patient-level analyses of test performance are of particular interest. Some of the studies included in this review reported per-patient analyses; however, no study clearly stated how results were defined (e.g. was the presence of any positive lesion regarded as a positive test for the whole patient). In addition, a number of studies reported data for one lesion per patient (treated as per-patient data in this assessment). These studies generally selected the largest lesion or the lesion 'most suspicious for malignancy' for inclusion in

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta17160

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Westwood, M., Joore, M., Grutters, J., Redekop, K., Armstrong, N., Lee, K., Gloy, V, Raatz, H., Misso, K., Severens, J., & Kleijnen, J.
Venue
Health Technol Assess
Published
2013-04
Volume
17
Issue
16
Pages
1-243
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W2046659471
Cited by
226
References
10
FWCI
2.81
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.