OBJECTIVE: To support a review of the guidance issued by the National Institute for Health and Clinical Excellence (NICE) in December 2000 by examining the current clinical and cost-effectiveness evidence on autologous cartilage transplantation. DATA SOURCES: Electronic databases. REVIEW METHODS: Evidence on clinical effectiveness was obtained from randomised trials, supplemented by data from selected observational studies for longer term results, and for the natural history of chondral lesions. Because of a lack of long-term results on outcomes such as later osteoarthritis and knee replacement, only illustrative modelling was done, using a range of assumptions that seemed reasonable, but were not evidence based. RESULTS: Four randomised controlled trials were included, as well as observational data from case series. The trials studied a total of 266 patients and the observational studies up to 101 patients. Two studies compared autologous chondrocyte implantation (ACI) with mosaicplasty, the third compared ACI with microfracture, and the fourth compared matrix-guided ACI (MACI) with microfracture. Follow-up was 1 year in one study, and up to 3 years in the remaining three studies. The first trial of ACI versus mosaicplasty found that ACI gave better results than mosaicplasty at 1 year. Overall, 88% had excellent or good results with ACI versus 69% with mosaicplasty. About half of the biopsies after ACI showed hyaline cartilage. The second trial of ACI versus mosaicplasty found little difference in clinical outcomes at 2 years. Disappointingly, biopsies from the ACI group showed fibrocartilage rather than hyaline cartilage. The trial of ACI versus microfracture also found only small differences in outcomes at 2 years. Finally, the trial of MACI versus microfracture contained insufficient long-term results at present, but the study does show the feasibility of doing ACI by the MACI technique. It also suggested that after ACI, it takes 2 years for full-thickness cartilage to be produced. Reliable costs per quality-adjusted life-year (QALY) could not be calculated owing to the absence of necessary data. Simple short-term modelling suggests that the quality of life gain from ACI versus microfracture would have to be between 70 and 100% greater over 2 years for it to be more cost-effective within the 20,000--30,000 pounds sterling per QALY cost-effectiveness thresholds. However, if the quality of life gains could be maintained for a decade, increments relative to microfracture would only have to be 10--20% greater to justify additional treatment costs within the cost-effectiveness band indicated above. Follow-up from the trials so far has only been up to 2 years, with longer term outcomes being uncertain. CONCLUSIONS: There is insufficient evidence at present to say that ACI is cost-effective compared with microfracture or mosaicplasty. Longer term outcomes are required. Economic modelling using some assumptions about long-term outcomes that seem reasonable suggests that ACI would be cost-effective because it is more likely to produce hyaline cartilage, which is more likely to be durable and to prevent osteoarthritis in the longer term (e.g. 20 years). Further research is needed into earlier methods of predicting long-term results. Basic science research is also needed into factors that influence stem cells to become chondrocytes and to produce high-quality cartilage, as it may be possible to have more patients developing hyaline cartilage after microfracture. Study is also needed into cost-effective methods of rehabilitation and the effect of early mobilisation on cartilage growth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vascularization is the key challenge in tissue engineering
Novosel, E. C., Kleinhans, C., & Kluger, P. J. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.03.004 · Cited by 1,062
Hobart, J., & Cano, S. (2009) · Health Technology Assessment · doi:10.3310/hta13120 · Cited by 621
Animal Models for Cartilage Regeneration and Repair
Chu, C. R., Szczodry, M., & Bruno, S. (2010) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0452 · Cited by 559
Advances in Regenerative Medicine and Tissue Engineering: Innovation and Transformation of Medicine
Dzobo, K., Thomford, N. E., Senthebane, D. A., Shipanga, H., Rowe, A., Dandara, C., Pillay, M., & Motaung, K. S. C. M. (2018) · Stem Cells International · doi:10.1155/2018/2495848 · Cited by 433
Self-monitoring of blood glucose in type 2 diabetes: systematic review
Clar, C., Barnard, K., Cummins, E., Royle, P., & Waugh, N. (2010) · Health Technology Assessment · doi:10.3310/hta14120 · Cited by 274
Self-citation
Metadata
- Authors
- Clar, C., Cummins, E., McIntyre, L., Thomas, S., Lamb, J., Bain, L., Jobanputra, P., & Waugh, N.
- Venue
- Health Technology Assessment
- Published
- 2005-12
- Volume
- 9
- Issue
- 47
- Pages
- iii-iv, ix
- ISSN
- 1366-5278 (ISSN-L)
- 2046-4924
- OpenAlex
- W2040560891
- Cited by
- 210
- References
- 0
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical and cost-effectiveness of autologous chondrocyte implantation for cartilage defects in knee joints: systematic review and economic evaluation. https://app.cochat.ai/papers/10.3310/hta9470
- The paper
- Clar, C., Cummins, E., McIntyre, L., Thomas, S., Lamb, J., Bain, L., Jobanputra, P., & Waugh, N. (2005). Clinical and cost-effectiveness of autologous chondrocyte implantation for cartilage defects in knee joints: systematic review and economic evaluation. Health Technology Assessment. https://doi.org/10.3310/hta9470
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.