The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Wearable Sensor Systems for Fall Risk Assessment: A Review
Open accessAbstract
Fall risk assessment and fall detection are crucial for the prevention of adverse and long-term health outcomes. Wearable sensor systems have been used to assess fall risk and detect falls while providing additional meaningful information regarding gait characteristics. Commonly used wearable systems for this purpose are inertial measurement units (IMUs), which acquire data from accelerometers and gyroscopes. IMUs can be placed at various locations on the body to acquire motion data that can be further analyzed and interpreted. Insole-based devices are wearable systems that were also developed for fall risk assessment and fall detection. Insole-based systems are placed beneath the sole of the foot and typically obtain plantar pressure distribution data. Fall-related parameters have been investigated using inertial sensor-based and insole-based devices include, but are not limited to, center of pressure trajectory, postural stability, plantar pressure distribution and gait characteristics such as cadence, step length, single/double support ratio and stance/swing phase duration. The acquired data from inertial and insole-based systems can undergo various analysis techniques to provide meaningful information regarding an individual's fall risk or fall status. By assessing the merits and limitations of existing systems, future wearable sensors can be improved to allow for more accurate and convenient fall risk assessment. This article reviews inertial sensor-based and insole-based wearable devices that were developed for applications related to falls. This review identifies key points including spatiotemporal parameters, biomechanical gait parameters, physical activities and data analysis methods pertaining to recently developed systems, current challenges, and future perspectives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A wireless wearable ECG sensor for long-term applications
Nemati, E., Deen, M., & Mondal, T. (2012) · IEEE Communications Magazine · doi:10.1109/mcom.2012.6122530 · Cited by 418
Self-citationAdvances in wearable technology and applications in physical medicine and rehabilitation
Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-2 · Cited by 385
Monitoring Methods of Human Body Joints: State-of-the-Art and Research Challenges
Faisal, A. I., Majumder, S., Mondal, T., Cowan, D., Naseh, S., & Deen, M. J. (2019) · Sensors · doi:10.3390/s19112629 · Cited by 187
Self-citation
Cited by
Human Fall Detection with Ultra-Wideband Radar and Adaptive Weighted Fusion
Huang, L., Zhu, A., Qian, M., & An, H. (2024) · Sensors · doi:10.3390/s24165294 · Cited by 11
Metadata
- Authors
- Subramaniam, S., Faisal, A. I., & Deen, M. J.
- Venue
- Frontiers in Digital Health
- Publisher
- Frontiers Media SA
- Published
- 2022-07-14
- Volume
- 4
- Pages
- 921506-921506
- ISSN
- 2673-253X (ISSN-L)
- OpenAlex
- W4285389684
- Cited by
- 175
- References
- 3
- FWCI
- 50.03
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable Sensor Systems for Fall Risk Assessment: A Review. https://app.cochat.ai/papers/10.3389/fdgth.2022.921506
- The paper
- Subramaniam, S., Faisal, A. I., & Deen, M. J. (2022). Wearable Sensor Systems for Fall Risk Assessment: A Review. Frontiers in Digital Health. https://doi.org/10.3389/fdgth.2022.921506
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.