CoChat

Issues in Continuous 24-h Core Body Temperature Monitoring in Humans Using an Ingestible Capsule Telemetric Sensor

Open access
Monnard, Cathriona R., Fares, Elie-Jacques, Calonne, Julie, Miles-Chan, Jennifer L., Montani, Jean-Pierre, Durrer, Dominique, Schutz, Yves, Dulloo, Abdul G. · 2017 · Frontiers in Endocrinology
Cited by 41

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background There is increasing interest in the use of pill-sized ingestible capsule telemetric sensors for assessing core body temperature (Tc) as a potential indicator of variability in metabolic efficiency and thrifty metabolic traits. The aim of this study was to investigate the feasibility and accuracy of measuring Tc using the CorTemp® system. Methods Tc was measured over an average of 20 hours in 27 human subjects, with measurements of energy expenditure made in the overnight fasted state at rest, during standardized low-intensity physical activity and after a 600 kcal mixed meal. Validation of accuracy of the capsule sensors was made ex-vivo against mercury and electronic thermometers across the physiological range (35-40°C) in morning and afternoon of 2 or 3 consecutive days. Comparisons between capsule sensors and thermometers were made using Bland-Altman analysis. Systematic bias, error and temperature drift over time were assessed. Results The circadian Tc profile classically reported in free-living humans was confirmed. Significant increases in Tc (+ 0.2 °C) were found in response to low-power cycling at 40-50W (~ 3-4 METs), but no changes in Tc were detectable during low-level isometric leg press exercise (< 2 METs) or during the peak postprandial thermogenesis induced by the 600 kcal meal. Issues of particular interest include fast ‘turbo’ gut transit with expulsion time of < 15h after capsule ingestion in one out of every 5 subjects and sudden erratic readings in tele-transmission of Tc. Furthermore, ex-vivo validation revealed a substantial mean bias (exceeding ± 0.5°C) between the Tc capsule readings and mercury or electronic thermometers in half of the capsules. When examined over 2 or 3 days, the initial bias (small or large) drifted in excess of ± 0.5°C in one out of every 4 capsules. Conclusion Since Tc is regulated within a very narrow range in the healthy homeotherm’s body (within 1°C), physiological investigations of Tc require great accuracy and precision (better than 0.1 °C). Although ingestible capsule methodology appears of great interest for non-invasively monitoring the transit gut temperature, new technology requires a reduction in the inherent error of measurement and elimination of temperature drift, and warrants more

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3389/fendo.2017.00130

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 41

Metadata

Authors
Monnard, C. R., Fares, E.-J., Calonne, J., Miles-Chan, J. L., Montani, J.-P., Durrer, D., Schutz, Y., & Dulloo, A. G.
Venue
Frontiers in Endocrinology
Published
2017-06-13
Volume
8
Pages
130-130
ISSN
1664-2392 (ISSN-L)
OpenAlex
W2626732743
Cited by
41
References
5
FWCI
1.40
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.