Issues in Continuous 24-h Core Body Temperature Monitoring in Humans Using an Ingestible Capsule Telemetric Sensor
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background There is increasing interest in the use of pill-sized ingestible capsule telemetric sensors for assessing core body temperature (Tc) as a potential indicator of variability in metabolic efficiency and thrifty metabolic traits. The aim of this study was to investigate the feasibility and accuracy of measuring Tc using the CorTemp® system. Methods Tc was measured over an average of 20 hours in 27 human subjects, with measurements of energy expenditure made in the overnight fasted state at rest, during standardized low-intensity physical activity and after a 600 kcal mixed meal. Validation of accuracy of the capsule sensors was made ex-vivo against mercury and electronic thermometers across the physiological range (35-40°C) in morning and afternoon of 2 or 3 consecutive days. Comparisons between capsule sensors and thermometers were made using Bland-Altman analysis. Systematic bias, error and temperature drift over time were assessed. Results The circadian Tc profile classically reported in free-living humans was confirmed. Significant increases in Tc (+ 0.2 °C) were found in response to low-power cycling at 40-50W (~ 3-4 METs), but no changes in Tc were detectable during low-level isometric leg press exercise (< 2 METs) or during the peak postprandial thermogenesis induced by the 600 kcal meal. Issues of particular interest include fast ‘turbo’ gut transit with expulsion time of < 15h after capsule ingestion in one out of every 5 subjects and sudden erratic readings in tele-transmission of Tc. Furthermore, ex-vivo validation revealed a substantial mean bias (exceeding ± 0.5°C) between the Tc capsule readings and mercury or electronic thermometers in half of the capsules. When examined over 2 or 3 days, the initial bias (small or large) drifted in excess of ± 0.5°C in one out of every 4 capsules. Conclusion Since Tc is regulated within a very narrow range in the healthy homeotherm’s body (within 1°C), physiological investigations of Tc require great accuracy and precision (better than 0.1 °C). Although ingestible capsule methodology appears of great interest for non-invasively monitoring the transit gut temperature, new technology requires a reduction in the inherent error of measurement and elimination of temperature drift, and warrants more
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy consumption in buildings and female thermal demand
Kingma, B., & van Marken Lichtenbelt, W. (2015) · Nature Climate Change · doi:10.1038/nclimate2741 · Cited by 240 · cited 1×
“Furthermore, future studies need to address the issue of whether the use of a fixed room temperature might also influence the Tc measurement, particularly when comparing people of different morphology, body fat distribution, and indeed when comparing men and women who may differ in thermal demand (34).”
BackgroundNighttime drop in body temperature: A physiological trigger for sleep onset?
Murphy, P. J., & Campbell, S. S. (1997) · Sleep · doi:10.1093/sleep/20.7.505 · Cited by 222
Adaptive thermogenesis in human body weight regulation: more of a concept than a measurable entity?
Dulloo, A. G., Jacquet, J., Montani, J., & Schutz, Y. (2012) · Obesity Reviews · doi:10.1111/j.1467-789x.2012.01041.x · Cited by 116
Self-citationCore body temperature in obesity
Heikens, M. J., Gorbach, A. M., Eden, H. S., Savastano, D. M., Chen, K. Y., Skarulis, M. C., & Yanovski, J. A. (2011) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.110.006270 · Cited by 65
Effect of heavy exercise on gastrointestinal transit in endurance athletes
Strid, H., Simrén, M., Störsrud, S., Stotzer, P.-O., & Sadik, R. (2011) · Scandinavian Journal of Gastroenterology · doi:10.3109/00365521.2011.558110 · Cited by 65
Cited by
Depner, C. M., Cheng, P. C., Devine, J. K., Khosla, S., de Zambotti, M., Robillard, R., Vakulin, A., & Drummond, S. P. A. (2020) · Sleep · doi:10.1093/sleep/zsz254 · Cited by 245
“Results from validation studies on many of these devices are mixed [61, 62].”
BackgroundDell’Isola, G. B., Cosentini, E., Canale, L., Ficco, G., & Dell’Isola, M. (2021) · Sensors · doi:10.3390/s21020346 · Cited by 101
Thermometry and interpretation of body temperature
Chen, W. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00102-2 · Cited by 72
Nandhra, G. K., Chaichanavichkij, P., Birch, M., & Scott, S. M. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12165272 · Cited by 26
“In one study [69], the subjects ingested the capsule in the afternoon, reporting a mean WGTT of 31.”
BackgroundMethodInfluentialCalonne, J., Arsenijevic, D., Scerri, I., Miles-Chan, J. L., Montani, J.-P., & Dulloo, A. G. (2019) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00092.2019 · Cited by 15
Self-citation
Metadata
- Authors
- Monnard, C. R., Fares, E.-J., Calonne, J., Miles-Chan, J. L., Montani, J.-P., Durrer, D., Schutz, Y., & Dulloo, A. G.
- Venue
- Frontiers in Endocrinology
- Publisher
- Frontiers Media SA
- Published
- 2017-06-13
- Volume
- 8
- Pages
- 130-130
- ISSN
- 1664-2392 (ISSN-L)
- OpenAlex
- W2626732743
- Cited by
- 41
- References
- 5
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.