Cortisol values during the standard-dose cosyntropin stimulation test: Personal experience with Elecsys cortisol II assay

Open access
Husni, Hasan, Abusamaan, Mohammed S., Dinparastisaleh, Roshan, Sokoll, Lori, Salvatori, Roberto, Hamrahian, Amir H. · 2022 · Frontiers in Endocrinology
Cited by 26

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Purpose: There has been debate regarding the appropriate cortisol cutoff during the cosyntropin stimulation test (CST) when newer cortisol assays are used. We aimed to evaluate the proper cortisol values during the standard dose CST in patients with normal hypothalamic-pituitary-adrenal (HPA) axis when the Elecsys® Cortisol II assay from Roche Diagnostics is used. Methods: We retrospectively reviewed the medical records of patients evaluated for possible adrenal insufficiency using the standard-dose (250 mcg) CST from January 2018 to December 2020 and eventually judged to have a normal HPA axis. All the CSTs were done in the outpatient setting. Evaluation by an endocrinologist, restrictive exclusion criteria including prior glucocorticoid and opioid use, and lack of glucocorticoid treatment for at least 6 months after the CST was used to define normal HPA axis. The results are reported in the median (range). Results: We identified 63 patients who met the inclusion criteria and were considered to have a normal HPA axis. The median age was 54.7 (27.6-89.1) years; 32 (51%) were female, and 27 (43%) were white. The duration of follow-up after the CST without any glucocorticoid replacement was 13.9 (6.3-43.9) months. Cortisol levels were 21.7 (15.7-29.1) µg/dl and 24.4 (17.9-35.8) µg/dl at 30- and 60-minutes after cosyntropin administration, respectively. The lowest cortisol levels at 30 and 60 minutes for patients with either normal TSH or gonadal axis (n=47) or in whom both axes were normal (n=18) were similar to the ones of the entire cohort. Conclusion: Our study supports using a lower than previously recommended cortisol cutoff value at 30 minutes after Cosyntropin using the Roche Elecsys® Cortisol II assay. The lowest cortisol levels in our cohort were 15.7 and 17.9 µg/dL at 30 and 60 minutes after the CST, respectively. Therefore, it is essential to consider the time of cortisol draw after cosyntropin administration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3389/fendo.2022.978238

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 26

Metadata

Authors
Husni, H., Abusamaan, M. S., Dinparastisaleh, R., Sokoll, L., Salvatori, R., & Hamrahian, A. H.
Venue
Frontiers in Endocrinology
Published
2022-08-18
Volume
13
Pages
978238-978238
ISSN
1664-2392 (ISSN-L)
OpenAlex
W4292416807
Cited by
26
References
15
FWCI
3.16
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.