A Comparative Analysis of Three Non-Invasive Human-Machine Interfaces for the Disabled
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In the framework of rehabilitation robotics, a major role is played by the human-machine interface (HMI) used to gather the patient's intent from biological signals, and convert them into control signals for the robotic artifact. Surprisingly, decades of research have not yet declared what the optimal HMI is in this context; in particular, the traditional approach based upon surface electromyography (sEMG) still yields unreliable results due to the inherent variability of the signal. To overcome this problem, the scientific community has recently been advocating the discovery, analysis, and usage of novel HMIs to supersede or augment sEMG; a comparative analysis of such HMIs is therefore a very desirable investigation. In this paper, we compare three such HMIs employed in the detection of finger forces, namely sEMG, ultrasound imaging, and pressure sensing. The comparison is performed along four main lines: the accuracy in the prediction, the stability over time, the wearability, and the cost. A psychophysical experiment involving ten intact subjects engaged in a simple finger-flexion task was set up. Our results show that, at least in this experiment, pressure sensing and sEMG yield comparably good prediction accuracies as opposed to ultrasound imaging; and that pressure sensing enjoys a much better stability than sEMG. Given that pressure sensors are as wearable as sEMG electrodes but way cheaper, we claim that this HMI could represent a valid alternative/augmentation to sEMG to control a multi-fingered hand prosthesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ridge regression: Biased estimation for nonorthogonal problems
Hoerl, A. E., & Kennard, R. W. (1970) · Technometrics · doi:10.1080/00401706.1970.10488634 · Cited by 9,648
Postural Hand Synergies for Tool Use
Santello, M., Flanders, M., & Soechting, J. F. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-23-10105.1998 · Cited by 1,215
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495 · cited 1×
“The community is therefore calling for novel human–machine interfaces (HMIs) to complement, augment, or substitute sEMG, together with the necessity to enforce simultaneous and proportional control using these signals (Fougner et al., 2012; Jiang et al., 2012).”
BackgroundThe SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286
Cited by
Ultra-sensitive and resilient compliant strain gauges for soft machines
Araromi, O. A., Graule, M. A., Dorsey, K. L., Castellanos, S., Foster, J. R., Hsu, W.-H., Passy, A. E., Vlassak, J. J., Weaver, J. C., Walsh, C. J., et al. (2020) · Nature · doi:10.1038/s41586-020-2892-6 · Cited by 511
Sim, K., Rao, Z., Zou, Z., Ershad, F., Lei, J., Thukral, A., Chen, J., Huang, Q.-A., Xiao, J., & Yu, C. (2019) · Science Advances · doi:10.1126/sciadv.aav9653 · Cited by 305
“However, these wearable HMIs are mostly semisoft (2, 3); therefore, they are uncomfortable to use, restrict the human body’s motion, and/or cannot adapt to the deformations from the human body’s dynamic range of motion (4, 5).”
Hong, K.-S., & Khan, M. J. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00035 · Cited by 267
Ahmadizadeh, C., Merhi, L.-K., Pousett, B., Sangha, S., & Menon, C. (2017) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2017.2747899 · Cited by 57
“The feasibility of gesture recognition in individuals with an upper-extremity amputation using FMG has been demonstrated [9], and the performances of FMGand EMG-based systems have been compared in multiple studies [7], [10], [11], with some showing that FMG can outperform EMG-based approaches [7], [11].”
BackgroundMethod
Metadata
- Authors
- Ravindra, V., & Castellini, C.
- Venue
- Frontiers in Neurorobotics
- Publisher
- Frontiers Media SA
- Published
- 2014-10-27
- Volume
- 8
- Pages
- 24-24
- ISSN
- 1662-5218 (ISSN-L)
- OpenAlex
- W2000035230
- Cited by
- 110
- References
- 4
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Comparative Analysis of Three Non-Invasive Human-Machine Interfaces for the Disabled. https://app.cochat.ai/papers/10.3389/fnbot.2014.00024
- The paper
- Ravindra, V., & Castellini, C. (2014). A Comparative Analysis of Three Non-Invasive Human-Machine Interfaces for the Disabled. Frontiers in Neurorobotics. https://doi.org/10.3389/fnbot.2014.00024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.