Genetically Encoded Voltage Indicators Are Illuminating Subcellular Physiology of the Axon
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
, form the bedrock of the electrical impulse in the brain known as the action potential. Several classes of mammalian neurons express combinations of nearly 100 different varieties of these two voltage-dependent channels and their subunits. Not surprisingly, this variability orchestrates a diversity of action potential shapes and firing patterns that have been studied in detail at neural somata. A remarkably understudied phenomena exists in subcellular compartments of the axon, where action potentials initiate synaptic transmission. Ion channel research was catalyzed by the invention of glass electrodes to measure electrical signals in cell membranes, however, progress in the field of neurobiology has been stymied by the fact that most axons in the mammalian CNS are far too small and delicate for measuring ion channel function with electrodes. These quantitative measurements of membrane voltage can be achieved within the axon using light. A revolution of optical voltage sensors has enabled exploring important questions of how ion channels regulate axon physiology and synaptic transmission. In this review we will consider advantages and disadvantages of different fluorescent voltage indicators and discuss particularly relevant questions that these indicators can elucidate for understanding the crucial relationship between action potentials and synaptic transmission.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Llinás, R. R. (1988) · Science · doi:10.1126/science.3059497 · Cited by 2,285 · cited 1×
“Although the squid axon had a binary Frontiers in Cellular Neuroscience | www.frontiersin.org 1 March 2019 | Volume 13 | Article 52 firing response to different stimulations, several firing patterns were discovered that differed considerably between cell types (Llinas, 1988; Bean, 2007).”
BackgroundThe action potential in mammalian central neurons
Bean, B. P. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2148 · Cited by 1,785 · cited 4×
“Although the squid axon had a binary Frontiers in Cellular Neuroscience | www.frontiersin.org 1 March 2019 | Volume 13 | Article 52 firing response to different stimulations, several firing patterns were discovered that differed considerably between cell types (Llinas, 1988; Bean, 2007).”
BackgroundInfluentialShepherd, G. M. G., & Harris, K. M. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-20-08300.1998 · Cited by 502 · cited 1×
“However, outside of these examples, wholecell patch clamp is not technically feasible for decoding AP waveforms and molecular modulators in en passant synapses due to their sub-micron diameters (Shepherd and Harris, 1998; Mishchenko et al., 2010).”
MethodSignal processing in the axon initial segment
Kole, M. H. P., & Stuart, G. J. (2012) · Neuron · doi:10.1016/j.neuron.2012.01.007 · Cited by 463
High-speed recording of neural spikes in awake mice and flies with a fluorescent voltage sensor
Gong, Y., Huang, C., Li, J. Z., Grewe, B. F., Zhang, Y., Eismann, S., & Schnitzer, M. J. (2015) · Science · doi:10.1126/science.aab0810 · Cited by 462
Membrane potential dynamics of GABAergic neurons in the barrel cortex of behaving mice
Gentet, L. J., Avermann, M., Matyas, F., Staiger, J. F., & Petersen, C. C. H. (2010) · Neuron · doi:10.1016/j.neuron.2010.01.006 · Cited by 429 · cited 2×
“Ace2N-mNeon not only can resolve APs in single cells within live animals, but provides robust responses in vivo with resolution for single cell and single AP recording in mice and fruit flies (Gong et al., 2015).”
BackgroundSynapse-Level Determination of Action Potential Duration by K + Channel Clustering in Axons
Rowan, M. J. M., DelCanto, G., Yu, J. J., Kamasawa, N., & Christie, J. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.05.035 · Cited by 66
Cited by
Imaging neurotransmitter and neuromodulator dynamics in vivo with genetically encoded indicators
Sabatini, B. L., & Tian, L. (2020) · Neuron · doi:10.1016/j.neuron.2020.09.036 · Cited by 203
Dong, C., Zheng, Y., Long-Iyer, K., Wright, E. C., Li, Y., & Tian, L. (2022) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-110520-031137 · Cited by 99
Falkovich, R., Aryal, S., Sheng, M., & Bathe, M. (2024) · doi:10.1101/2024.10.28.620504 · Cited by 2
Metadata
- Authors
- Panzera, L. C., & Hoppa, M. B.
- Venue
- Frontiers in Cellular Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2019-03-01
- Volume
- 13
- Pages
- 52-52
- ISSN
- 1662-5102 (ISSN-L)
- OpenAlex
- W2918851988
- Cited by
- 42
- References
- 7
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Genetically Encoded Voltage Indicators Are Illuminating Subcellular Physiology of the Axon. https://app.cochat.ai/papers/10.3389/fncel.2019.00052
- The paper
- Panzera, L. C., & Hoppa, M. B. (2019). Genetically Encoded Voltage Indicators Are Illuminating Subcellular Physiology of the Axon. Frontiers in Cellular Neuroscience. https://doi.org/10.3389/fncel.2019.00052
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.