Tools for brain-computer interaction: a general concept for a hybrid BCI
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The aim of this work is to present the development of a hybrid Brain-Computer Interface (hBCI) which combines existing input devices with a BCI. Thereby, the BCI should be available if the user wishes to extend the types of inputs available to an assistive technology system, but the user can also choose not to use the BCI at all; the BCI is active in the background. The hBCI might decide on the one hand which input channel(s) offer the most reliable signal(s) and switch between input channels to improve information transfer rate, usability, or other factors, or on the other hand fuse various input channels. One major goal therefore is to bring the BCI technology to a level where it can be used in a maximum number of scenarios in a simple way. To achieve this, it is of great importance that the hBCI is able to operate reliably for long periods, recognizing and adapting to changes as it does so. This goal is only possible if many different subsystems in the hBCI can work together. Since one research institute alone cannot provide such different functionality, collaboration between institutes is necessary. To allow for such a collaboration, a new concept and common software framework is introduced. It consists of four interfaces connecting the classical BCI modules: signal acquisition, preprocessing, feature extraction, classification, and the application. But it provides also the concept of fusion and shared control. In a proof of concept, the functionality of the proposed system was demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 2×
“For individuals suffering from severe palsy caused by muscle dystrophy, amyotrophic lateral sclerosis (ALS), or brainstem stroke, such a BCI constitutes a possible way to communicate with the environment (Birbaumer et al., 1999; Nijboer et al., 2008; Kübler et al., 2009).”
BackgroundA P300-based brain–computer interface for people with amyotrophic lateral sclerosis
Nijboer, F., Sellers, E. W., Mellinger, J., Jordan, M. A., Matuz, T., Furdea, A., Halder, S., Mochty, U., Krusienski, D. J., Vaughan, T. M., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.034 · Cited by 633 · cited 1×
“For individuals suffering from severe palsy caused by muscle dystrophy , amyotrophic lateral sclerosis (ALS), or brainstem stroke, such a BCI constitutes a possible to communicate with the environment (Birbaumer et al., 1999; Nijboer et al., 2008; Kübler et al., 2009).”
BackgroundEEG-based neuroprosthesis control: A step towards clinical practice
Müller-Putz, G. R., Scherer, R., Pfurtscheller, G., & Rupp, R. (2005) · Neuroscience Letters · doi:10.1016/j.neulet.2005.03.021 · Cited by 477 · cited 1×
“BCIs can also be used to control neuroprostheses in patients suffering from a high spinal cord injury (SCI), for example by using Functional Electrical Stimulation (FES) for grasp restoration (Müller-Putz et al., 2005).”
BackgroundSelf-citation
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“However, EEG signals could be combined with other sensory inputs in the framework of the so-called hybrid BCIs [51,52] in order to decode user’s high-level commands more reliably.”
BackgroundSoekadar, S. R., Witkowski, M., Gómez, C., Opisso, E., Medina, J., Cortese, M., Cempini, M., Carrozza, M. C., Cohen, L. G., Birbaumer, N., et al. (2016) · Science Robotics · doi:10.1126/scirobotics.aag3296 · Cited by 242
Leeb, R., Perdikis, S., Tonin, L., Biasiucci, A., Tavella, M., Creatura, M., Molina, A., Al-Khodairy, A., Carlson, T., & Millán, J. D. R. (2013) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2013.08.004 · Cited by 166
“However, current day BCIs offer low information throughput and 18 are insufficient for the full dexterous and sustained control of these complex 19 applications.”
BackgroundInfluentialLi, Y., Pan, J., Long, J., Yu, T., Wang, F., Yu, Z., & Wu, W. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2469106 · Cited by 117
“BCI-Based Shared Control Systems In multimodal BCIs of this type, BCIs are combined with other intelligent systems to achieve shared control and to make the BCI systems more reliable, flexible, user friendly, and efficient by allowing the subjects to focus their attention on the ultimate target while ignoring lowlevel…”
MethodClinical evaluation of BrainTree, a motor imagery hybrid BCI speller
Perdikis, S., Leeb, R., Williamson, J., Ramsay, A., Tavella, M., Desideri, L., Hoogerwerf, E.-J., Al-Khodairy, A., Murray-Smith, R., & Millán, J. D. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036003 · Cited by 85
“Finally, a key ingredient for the successful operation of the BrainTree speller is that we have enhanced it with data-compression human-computer interaction (HCI) mechanisms exploiting contextual information provided through a language model, as well as an errorhandling mechanism following a hybrid BCI approach [37, 3…”
Method
Metadata
- Authors
- Müller-Putz, G. R.
- Venue
- Frontiers in Neuroinformatics
- Publisher
- Frontiers Media SA
- Published
- 2011
- Volume
- 5
- Pages
- 30-30
- ISSN
- 1662-5196 (ISSN-L)
- OpenAlex
- W2145832008
- Cited by
- 142
- References
- 5
- FWCI
- 7.24
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.