Quality Control of Structural MRI Images Applied Using FreeSurfer—A Hands-On Workflow to Rate Motion Artifacts
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
In structural magnetic resonance imaging motion artifacts are common, especially when not scanning healthy young adults. It has been shown that motion affects the analysis with automated image-processing techniques (e.g., FreeSurfer). This can bias results. Several developmental and adult studies have found reduced volume and thickness of gray matter due to motion artifacts. Thus, quality control is necessary in order to ensure an acceptable level of quality and to define exclusion criteria of images (i.e., determine participants with most severe artifacts). However, information about the quality control workflow and image exclusion procedure is largely lacking in the current literature and the existing rating systems differ. Here, we propose a stringent workflow of quality control steps during and after acquisition of T1-weighted images, which enables researchers dealing with populations that are typically affected by motion artifacts to enhance data quality and maximize sample sizes. As an underlying aim we established a thorough quality control rating system for T1-weighted images and applied it to the analysis of developmental clinical data using the automated processing pipeline FreeSurfer. This hands-on workflow and quality control rating system will aid researchers in minimizing motion artifacts in the final data set, and therefore enhance the quality of structural magnetic resonance imaging studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fischl, B., Salat, D. H., Busa, E., Albert, M., Dieterich, M., Haselgrove, C., van der Kouwe, A., Killiany, R., Kennedy, D., Klaveness, S., et al. (2002) · Neuron · doi:10.1016/s0896-6273(02)00569-x · Cited by 8,610
The influence of head motion on intrinsic functional connectivity MRI
Van Dijk, K. R. A., Sabuncu, M. R., & Buckner, R. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.044 · Cited by 2,344
Attention-deficit/hyperactivity disorder is characterized by a delay in cortical maturation
Shaw, P., Eckstrand, K., Sharp, W., Blumenthal, J., Lerch, J. P., Greenstein, D., Clasen, L., Evans, A., Giedd, J., & Rapoport, J. L. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707741104 · Cited by 1,819
Castellanos, F. X. (2002) · JAMA · doi:10.1001/jama.288.14.1740 · Cited by 1,646
Recent progress and outstanding issues in motion correction in resting state fMRI
Power, J. D., Schlaggar, B. L., & Petersen, S. E. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.10.044 · Cited by 957 · cited 2×
“This is in contrast to functional MRI (fMRI) where techniques such as “spikes > 3mm” after automated realignment preprocessing or thresholds based on “scrubbing” (for review see Power et al., 2015) are used to exclude participants due to motion.”
BackgroundResultHead motion during MRI acquisition reduces gray matter volume and thickness estimates
Reuter, M., Tisdall, M. D., Qureshi, A., Buckner, R. L., van der Kouwe, A. J. W., & Fischl, B. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.006 · Cited by 457
Ducharme, S., Albaugh, M. D., Nguyen, T.-V., Hudziak, J. J., Mateos-Pérez, J. M., Labbe, A., Evans, A. C., & Karama, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.010 · Cited by 304
Brain Structure Abnormalities in Early-Onset and Adolescent-Onset Conduct Disorder
Fairchild, G., Passamonti, L., Hurford, G., Hagan, C. C., von dem Hagen, E. A. H., van Goozen, S. H. M., Goodyer, I. M., & Calder, A. J. (2011) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2010.10081184 · Cited by 242 · cited 1×
“For example, some authors note that T1-weighted images have been “checked for scanner artifacts and gross neuroanatomical abnormalities” (Fairchild et al., 2011, 2013), others merely state images have been “quality controlled for motion” (Dirlikov et al., 2015), or that they underwent “visual…”
BackgroundMorphometric Brain Abnormalities in Boys With Conduct Disorder
HUEBNER, T., VLOET, T. D., MARX, I., KONRAD, K., FINK, G. R., HERPERTZ, S. C., & HERPERTZ-DAHLMANN, B. (2008) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1097/chi.0b013e3181676545 · Cited by 239
OVERMEYER, S., BULLMORE, E. T., SUCKLING, J., SIMMONS, A., WILLIAMS, S. C. R., SANTOSH, P. J., & TAYLOR, E. (2001) · Psychological Medicine · doi:10.1017/s0033291701004706 · Cited by 209
Alexander-Bloch, A., Clasen, L., Stockman, M., Ronan, L., Lalonde, F., Giedd, J., & Raznahan, A. (2016) · Human Brain Mapping · doi:10.1002/hbm.23180 · Cited by 178 · cited 1×
“Finally, even though the proposed QC rating system is able to determine the most problematic T1-weighted images, it must be noted that in-scanner motion might lead to biases in anatomical estimations, even at levels which do not manifest in visible motion artifacts (Alexander-Bloch et al., 2016).”
BackgroundCao, Q., Sun, L., Gong, G., Lv, Y., Cao, X., Shuai, L., Zhu, C., Zang, Y., & Wang, Y. (2010) · Brain Research · doi:10.1016/j.brainres.2009.10.031 · Cited by 98 · cited 2×
“, 2015), or that they underwent “visual inspection” (Castellanos et al., 2002; Cao et al., 2010) or “internal quality control” (Fjell et al.”
Background
Cited by
MRIQC: Advancing the automatic prediction of image quality in MRI from unseen sites
Esteban, O., Birman, D., Schaer, M., Koyejo, O. O., Poldrack, R. A., & Gorgolewski, K. J. (2017) · PLOS ONE · doi:10.1371/journal.pone.0184661 · Cited by 920
Herting, M. M., Johnson, C., Mills, K. L., Vijayakumar, N., Dennison, M., Liu, C., Goddings, A.-L., Dahl, R. E., Sowell, E. R., Whittle, S., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.020 · Cited by 185
“Nonetheless, future studies could benefit from employing standardized and well-documented QC procedures (Backhausen et al., 2016), and/or methods for tracking in-scanner motion, automated QC assessment, and motion correction procedures (further discussed in Vijayakumar et al.”
Self-citationRemer, J., Croteau-Chonka, E., Dean, D. C., D’Arpino, S., Dirks, H., Whiley, D., & Deoni, S. C. L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.010 · Cited by 152
Structural brain development: A review of methodological approaches and best practices
(2017) · doi:10.1016/j.dcn.2017.11.008 · Cited by 124
Herting, M. M., Azad, A., Kim, R., Tyszka, J. M., Geffner, M. E., & Kim, M. S. (2020) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaa023 · Cited by 41
Self-citation
Metadata
- Authors
- Backhausen, L. L., Herting, M. M., Buse, J., Roessner, V., Smolka, M. N., & Vetter, N. C.
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2016-12-06
- Volume
- 10
- Pages
- 558-558
- ISSN
- 1662-453X (ISSN-L)
- OpenAlex
- W2560195767
- Cited by
- 147
- References
- 12
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.