Recent advances in vascularized tumor-on-a-chip
Open accessThe DOI matches its Crossref record; 101 of the 101 references it cites were found in a registry or an index.
Abstract
The vasculature plays a critical role in cancer progression and metastasis, representing a pivotal aspect in the creation of cancer models. In recent years, the emergence of organ-on-a-chip technology has proven to be a robust tool, capable of replicating in vivo conditions with exceptional spatiotemporal resolution, making it a significant asset in cancer research. This review delves into the latest developments in 3D microfluidic vascularized tumor models and their applications in vitro , focusing on heterotypic cellular interactions, the mechanisms of metastasis, and therapeutic screening. Additionally, the review examines the benefits and drawbacks of these models, as well as the future prospects for their advancement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Metastasis to the peritoneum is accompanied by an abnormal accumulation of ascitic fluid rich in cells and proteins, and this is associated with a poor median patient survival (Finkernagel et al., 2019; Huang and Tu, 2023).”
From Microphysiological systems as models for immunologically ‘cold’ tumors (2024) · cites this paper as Huang and Tu, 2023
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Emerging Biological Principles of Metastasis
Lambert, A. W., Pattabiraman, D. R., & Weinberg, R. A. (2017) · Cell · doi:10.1016/j.cell.2016.11.037 · Cited by 3,067 · cited 1×
“In addition to delivering oxygen, nutrients, and drugs, as well as removing metabolic wastes, the vasculature also serves as an important route for tumor metastasis, which accounts for approximately 90% of cancer-associated deaths (6).”
BackgroundExtracellular vesicles in cancer — implications for future improvements in cancer care
Xu, R., Rai, A., Chen, M., Suwakulsiri, W., Greening, D. W., & Simpson, R. J. (2018) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-018-0036-9 · Cited by 1,445 · cited 1×
“Cancer cell-derived extracellular vesicles carry cargos such as oncoproteins and miRNA that may aid tumor progression by shaping the TME and establishing pre-metastatic niche (62).”
BackgroundPDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,190 · cited 1×
“Furthermore, the fabrication process is somewhat time-consuming, and there is also concern about the nature of PDMS, which can absorb small-molecule drugs (98), making it not the most ideal material for use in drug screening.”
BackgroundNanomaterials for cancer therapy: current progress and perspectives
Cheng, Z., Li, M., Dey, R., & Chen, Y. (2021) · Journal of Hematology & Oncology · doi:10.1186/s13045-021-01096-0 · Cited by 1,168
Mechanical memory and dosing influence stem cell fate
Yang, C., Tibbitt, M. W., Basta, L., & Anseth, K. S. (2014) · Nature Materials · doi:10.1038/nmat3889 · Cited by 1,160 · cited 1×
“, cell behavior can be regulated by its past mechanical environment (64, 65).”
BackgroundModelling cancer in microfluidic human organs-on-chips
Sontheimer-Phelps, A., Hassell, B. A., & Ingber, D. E. (2019) · Nature Reviews Cancer · doi:10.1038/s41568-018-0104-6 · Cited by 906
Exploiting senescence for the treatment of cancer
Wang, L., Lankhorst, L., & Bernards, R. (2022) · Nature Reviews Cancer · doi:10.1038/s41568-022-00450-9 · Cited by 867 · cited 1×
“This is especially important for senescent cells, which is common in cancer drug treatment (85).”
BackgroundWeisel, J. W. (2005) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(05)70008-5 · Cited by 816 · cited 1×
“Thrombin cleavage of fibrinogen into fibrin exposes the interaction site that allows fibrin monomers to self-polymerize and form fibrillar structure (22).”
BackgroundHuttenlocher, A., & Horwitz, A. R. (2011) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a005074 · Cited by 761 · cited 1×
“Integrin signaling plays important roles in cell migration (70).”
BackgroundMechanisms of lymphatic metastasis
Karaman, S., & Detmar, M. (2014) · Journal of Clinical Investigation · doi:10.1172/jci71606 · Cited by 584 · cited 1×
“However, in an in vivo context, lymphatic vessels are also an important route for metastasis in various types of cancer (97).”
Background
Research works printed but not linked: 1
- Adair TH Montani JP. Chapter 1, overview of angiogenesis. In: Angiogenesis. San Rafael (CA: Morgan & Claypool Life Sciences (2010). 21452444
Cited by
Cancer-on-a-chip for precision cancer medicine
Liu, L., Wang, H., Chen, R., Song, Y., Wei, W., Baek, D. S. H., Gillin, M., Kurabayashi, K., & Chen, W. (2025) · Lab on a Chip · doi:10.1039/d4lc01043d · Cited by 52
Imaging 3D cell cultures with optical microscopy
Hsieh, H.-C., Han, Q., Brenes, D., Bishop, K. W., Wang, R., Wang, Y., Poudel, C., Glaser, A. K., Freedman, B., Vaughan, J. C., et al. (2025) · Nature Methods · doi:10.1038/s41592-025-02647-w · Cited by 51
“Organ-on-a-chip platforms can exhibit semi-realistic vascular networks and are often used for 3D cell culture research on angiogenesis 193 .”
Monteiro, C. F., Deus, I. A., Silva, I., Duarte, I. F., Custódio, C. A., & Mano, J. F. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202315940 · Cited by 26
Vascularized tumor models for the evaluation of drug delivery systems: a paradigm shift
Lopez-Vince, E., Wilhelm, C., & Simón‐Yarza, T. (2024) · Drug Delivery and Translational Research · doi:10.1007/s13346-024-01580-3 · Cited by 26
How organ-on-a-chip is advancing cancer research and oncology - a cancer hallmarks’ perspective
Avula, L. R., & Grodzinski, P. A. (2024) · Frontiers in Lab on a Chip Technologies · doi:10.3389/frlct.2024.1487377 · Cited by 26
Recent Advances and Future Perspectives in Vascular Organoids and Vessel-on-Chip
Cheruku, G. R., Wilson, C. V., Raviendran, S., & Xiao, Q. (2024) · Organoids · doi:10.3390/organoids3030014 · Cited by 25
Poljak, I., Chiappini, C., & Adriani, G. (2026) · Lab on a Chip · doi:10.1039/d5lc01060h · Cited by 17
Kim, H., Cho, S., & Kim, H. N. (2025) · Macromolecular Bioscience · doi:10.1002/mabi.202500240 · Cited by 18
Microphysiological systems as models for immunologically ‘cold’ tumors
Gaebler, D., Hachey, S. J., & Hughes, C. C. W. (2024) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2024.1389012 · Cited by 14
“Metastasis to the peritoneum is accompanied by an abnormal accumulation of ascitic fl uid rich in cells and proteins, and this is associated with a poor median patient survival (Finkernagel et al., 2019; Huang and Tu, 2023).”
BackgroundKumar, N., Samanta, B., Manattayil, J. K., Raghunathan, V., Sen, P., & Bhat, R. (2025) · Small · doi:10.1002/smll.202405998 · Cited by 14
Microfluidic Model of the Alternative Vasculature in Neuroblastoma
Villasante, A., Lopez-Martinez, M. J., Quiñonero, G., García‐Lizarribar, A., Peng, X., & Samitier, J. (2024) · Congreso Anual de la Sociedad Española de Ingeniería Biomédica (CASEIB) · doi:10.1007/s44164-023-00064-x · Cited by 14
Targeted Cancer Therapy‐on‐A‐Chip
Abed, H., Radha, R., Anjum, S., Paul, V., AlSawaftah, N., Pitt, W. G., Ashammakhi, N. A., & Husseini, G. A. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202400833 · Cited by 13
Parihar, P., Sunildutt, N., Rahim, C. S. A., Samantasinghar, A., Lim, J., & Choi, K. H. (2024) · Advanced Therapeutics · doi:10.1002/adtp.202300410 · Cited by 10
Spheroid‐on‐a‐Chip Platforms for Tumor Microenvironment and Drug Development
Uzabakiriho, P. C., Jiajun, F., Nguchu, B. A., Iqbal, S., Manishimwe, C., & Shaw, P. M. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202401821 · Cited by 9
Munoz, J. M., Pileggi, G. F., Nucci, M. P., Alves, A. H., Pedrini, F., Valle, N. M. E., Mamani, J. B., Oliveira, F. A., Lopes, A. T., Carreño, M. N. P., et al. (2024) · Pharmaceutics · doi:10.3390/pharmaceutics16091156 · Cited by 8
“This in silico study, utilizing organ-on-a-chip models to mimic normal and irregular vascular systems as found in tumors [39,40], was crucial to understanding how the specific vasculature of tumors, often more anomalous and dense than that of healthy tissues [41], influences heat dissipation.”
MethodTumor Immune Engineering: Developing In Vitro Assays to Understand the Tumor–Immune Crosstalk
Iyer, R. N., Vartak, M., & Dey, T. (2025) · Advanced Biology · doi:10.1002/adbi.202400735 · Cited by 4
Microphysiological systems for metastasis research: a stepwise approach
Sharko, V., Ochoa, I., & Solanas, E. (2025) · Cellular Oncology · doi:10.1007/s13402-025-01110-4 · Cited by 5
“Another significant limitation is the simplified representation of the vascular niche, which fre - quently lacks integrated stromal or immune components— critical elements for capturing realistic tumor–vasculature interactions [130].”
InfluentialHwang, S., Lee, D., Lee, Y.-G., Ahn, J., & Kang, Y. (2025) · Materials Today Bio · doi:10.1016/j.mtbio.2025.102240 · Cited by 5
Shao, H., & Young, E. W. K. (2026) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5c01713 · Cited by 3
Tellez, C. H., Camenisch, S., Wick, P., Sánchez-Arreola, E., & Ayala‐Nunez, V. (2026) · npj Precision Oncology · doi:10.1038/s41698-026-01403-3 · Cited by 2
“The incorporation of a perfusable vascular bed into the relapse GBM-on-a-chip platform is essential for studying angiogenesis driven by TAM-secreted cytokines 134 .”
The Tumor Microenvironment: Translating Intravital Insights into Microphysiological Systems
Imparato, G., Mazio, C., Nevola, P., & Netti, P. A. (2026) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-026-00910-4 · Cited by 2
Paradiso, A., Saglam‐Metiner, P., Walejewska, E., Volpi, M., Dogan, B., Filiz, Y., Sarıer, İ., Martinez, D. C., Coban, R., Takanlou, L. S., et al. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202505937 · Cited by 1
Baranowska, P., Flont, M., Żuchowska, A., Brzózka, Z., & Jastrzębska, E. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15978-7.00048-5
Translating Preclinical Studies into the Clinic: Assays and Endpoints Selected to Determine Efficacy
Horsman, M. R., & Siemann, D. W. (2025) · Molecular Cancer Therapeutics · doi:10.1158/1535-7163.mct-25-0739
Mechanobiology of cancer-associated thrombosis: from molecular mechanisms to therapeutic innovation
Wang, Z. T., Hu, Y. R., Zhan, Z., Dupuy, A., Yao, Z., Liu, X., & Ju, L. A. (2026) · Journal of Nanobiotechnology · doi:10.1186/s12951-026-04411-4 · Cited by 1
Microgravity as a platform for cancer progression studies and stem-cell-based therapeutic innovation
Nagarajan, V., Janarthanan, G., & Vijayavenkataraman, S. (2026) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ae716a
Consolidated and next-generation models in DDS nanotoxicology assessment: Where do we stand
D’Intino, E., Stacchini, F. R., Fabiano, M. G., Marianecci, C., & Carafa, M. (2026) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2026.108598
Li, W., Wang, Y., Cui, Y., Ma, X., Zhu, Q., Chen, H., Gan, F., Wu, Q., Lu, Z., Sun, Y., et al. (2026) · International Journal of Bioprinting · doi:10.36922/ijb026230236
Hydrodynamic dispersion drives viral–cellular contact for gene delivery in porous media
Srikanth, V., Mallory, M., Ulmer, A. J., Legant, W. R., Kuznetsov, A. V., & Brudno, Y. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2603906123
“…applications such as nanoparticle - mediated drug delivery inside implantable biomaterials, and the precise design of biomimetic lab - on - a - chip models, such as vascularized tumor - on - a - chip platforms (64), to accurately replicate complex physiological transport microenvironments.”
Models of high-grade serous carcinoma of tubo-ovarian origin
Padmanabhan, A., Dwivedi, S. K. D., Merritt, M. A., Verma, P., Buckanovich, R. J., Lang, J. D., Dimmick, H. L., Nephew, K. P., Drapkin, R., Brubaker, L. W., et al. (2026) · Oncology Reviews · doi:10.3389/or.2026.1849834 · Cited by 1
Li, Y., Yang, Y., Zhao, L., Bian, Z., & Zhang, Z. (2026) · Bioengineering · doi:10.3390/bioengineering13080947
“A structural vascular image does not establish transport function [16–18, 37,38].”
Cretti, G., Ballerini, M., Mantegazza, A., Occhetta, P., & Rasponi, M. (2026) · Advanced Materials Technologies · doi:10.1002/admt.71277
Tian, H., Li, G., Lian, Y., Liu, H., Fang, Y., Tong, Y., He, Z., Bian, Y., & Wei, G. (2026) · Frontiers in Pharmacology · doi:10.3389/fphar.2026.1926341
“Recent reviews and bibliometric studies have examined organoid models, tumor-on-chip systems, vascularized tumor platforms, and microfluidic approaches to cancer modeling from partially overlapping perspectives (Gonçalves et al., 2022; Huang and Tu, 2023; Trujillo-de Santiago et al., 2019).”
Translational insights and clinical relevance of glioblastoma 3D in vitro models
Orlanno, C., Lamparelli, E. P., Lancellotti, A., Pugliese, G., Chiavelli, C., İaconetta, G., Guarnieri, D., Santoro, A., & Porta, G. D. (2026) · Biofabrication · doi:10.1088/1758-5090/aeadd0
Rong, Y. A. N., Yinuo, H. E., ZHANG, Y., Xiaxia, W. A. N. G., Meng, Y. U., Jiuming, H., Huarong, X. U., & Yongjian, A. I. (2026) · Analysis and Testing Technology and Instruments · doi:10.3724/j.1006-3757.2026.05.002
Sharko, V., Olaizola‐Rodrigo, C., Bayona, C., Ranđelović, T., Monge, R., Solanas, E., Oliván, S., & Ochoa, I. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.71910
Metadata
- Authors
- Huang, C. B. X., & Tu, T.-Y.
- Affiliations
- National Cheng Kung University (TW)
- Medical Device Innovation Center (TW)
- Corresponding author
- Tu, Ting-Yuan
- ORCID
- Tu, Ting-Yuan
- Venue
- Frontiers in Oncology
- Publisher
- Frontiers Media SA
- Published
- 2023-03-30
- Volume
- 13
- Pages
- 1150332-1150332
- ISSN
- 2234-943X (ISSN-L)
- PMC
- PMC10099572
- OpenAlex
- W4361270328
- Cited by
- 34
- References
- 101
- Citations by year
- 2026: 13 · 2025: 10 · 2024: 11
- FWCI
- 0.76
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Frontiers in Oncology (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Ministry of Science and Technology, Taiwan (MOST 110-2636-B-006-013-, MOST 110-2740-B-006-002, MOST 111-2740-B-006-002, MOST 111-2636-B-006-010-)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Oncology › Cancer Cells and Metastasis
- Keywords
- tumor-on-a-chip, organ-on-a-chip, tumor vasculature, metastasis, heterotypic cell interactions, in vitro tumor model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.