The Relationship Between Lactate and Ventilatory Thresholds in Runners: Validity and Reliability of Exercise Test Performance Parameters
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The aims of this study were (1) to establish the best fit between ventilatory and lactate exercise performance parameters in running and (2) to explore novel alternatives to estimate the maximal aerobic speed (MAS) in well trained runners. Twenty-two trained male athletes (V ̇O2max 60.2 ± 4.3 ml·kg·min-1) completed three maximal graded exercise tests (GXT): (1) a preliminary GXT to determine individuals’ MAS; (2) two experimental GXT individually adjusted by MAS to record the speed associated to the main aerobic-anaerobic transition events measured by indirect calorimetry and capillary blood lactate. Athletes also performed several 30 min constant running tests to determine the maximal lactate steady state (MLSS). Reliability analysis revealed low CV ( 0.91) for all determinations except V-Slope (ICC = 0.84). Validity analysis showed that LT, LT+1.0 and LT+3.0 mMol·L-1 were solid predictors of VT1 (-0.3 km∙h-1; bias = 1.2; ICC = 0.90; p = 0.57), MLSS (-0.2 km∙h-1; bias = 1.2; ICC = 0.84; p = 0.74) and VT2 (< 0.1 km∙h-1; bias = 1.3; ICC = 0.82; p = 0.99) respectively. MLSS was identified as a different physiological event and a midpoint between VT1 (bias = -2.0 km∙h-1) and VT2 (bias = 2.3 km∙h-1). MAS was accurately estimated (SEM ± 0.3 km∙h-1) from peak velocity (Vpeak) attained during GXT with the equation: MASEST (km·h-1) = Vpeak (km·h-1) * 0.8348 + 2.308. Current individualized GXT protocol based on individuals’ MAS was solid to determine both maximal and submaximal physiological parameters. Lactate threshold tests can be a valid and reliable alternative to VT and MLSS to identify the workloads at the transition from aerobic to anaerobic metabolism in well-trained runners. In contrast with traditional assumption, the MLSS constituted a midpoint physiological event between VT1 and VT2 in runners. The Vpeak stands out as a powerful predictor of MAS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muscle glycogen utilization during prolonged strenuous exercise when fed carbohydrate
Coyle, E. F., Coggan, A. R., Hemmert, M. K., & Ivy, J. L. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.61.1.165 · Cited by 1,022
The Effect of Endurance Training on Parameters of Aerobic Fitness
Jones, A. M., & Carter, H. (2000) · Sports Medicine · doi:10.2165/00007256-200029060-00001 · Cited by 935
Validity and reliability of combining three methods to determine ventilatory threshold
GASKILL, S. E., RUBY, B. C., WALKER, A. J., SANCHEZ, O. A., SERFASS, R. C., & LEON, A. S. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00007 · Cited by 444
Mann, T. N., Lamberts, R. P., & Lambert, M. I. (2014) · Sports Medicine · doi:10.1007/s40279-014-0197-3 · Cited by 379
Physiological Differences Between Cycling and Running: Lessons from Triathletes
Millet, G. P., Vleck, V. E., & Bentley, D. J. (2009) · Sports Medicine · doi:10.2165/00007256-200939030-00002 · Cited by 329
Blood lactate diagnostics in exercise testing and training.
Beneke, R., Leithäuser, R. M., & Ochentel, O. (2011) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.6.1.8 · Cited by 311 · cited 1×
“A further method to set individual exercise intensity is based on capillary blood lactate (CBL) measurements (Beneke et al., 2011).”
MethodPlasma lactate accumulation and distance running performance
FARRELL, P. A., WILMORE, J. H., COYLE, E. F., BILLING, J. E., & COSTILL, D. L. (1979) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-197901140-00005 · Cited by 279
Methodological aspects of maximal lactate steady state-implications for performance testing
Beneke, R. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0783-1 · Cited by 264
Validity and reliability of ventilatory and blood lactate thresholds in well-trained cyclists
Pallarés, J. G., Morán-Navarro, R., Ortega, J. F., Fernández-Elías, V. E., & Mora-Rodriguez, R. (2016) · PLOS ONE · doi:10.1371/journal.pone.0163389 · Cited by 180
Self-citationScharhag‐Rosenberger, F., Walitzek, S., Kindermann, W., & Meyer, T. (2012) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2010.01139.x · Cited by 118
Cited by
An Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
Vasquez Bonilla, A., González-Custodio, A., Timón, R., Cardenosa, A., Camacho-Cardenosa, M., & Olcina, G. (2023) · Biology of Sport · doi:10.5114/biolsport.2023.114288 · Cited by 22
“VT1 was determined using the criteria of an increase in ventilatory equivalent of oxygen (VE/VO 2 ) with no concomitant increase in ventilatory equivalent of carbon dioxide (VE/VCO 2 ) [22].”
Kim, K. J., Rivas, E., Prejean, B., Frisco, D., Young, M., & Downs, M. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.782167 · Cited by 17
Metadata
- Authors
- Cerezuela-Espejo, V., Courel-Ibáñez, J., Morán-Navarro, R., Martínez-Cava, A., & Pallarés, J. G.
- Venue
- Frontiers in Physiology
- Publisher
- Frontiers Media SA
- Published
- 2018-09-25
- Volume
- 9
- Pages
- 1320-1320
- ISSN
- 1664-042X (ISSN-L)
- OpenAlex
- W2889663548
- Cited by
- 96
- References
- 10
- FWCI
- 7.60
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Relationship Between Lactate and Ventilatory Thresholds in Runners: Validity and Reliability of Exercise Test Performance Parameters. https://app.cochat.ai/papers/10.3389/fphys.2018.01320
- The paper
- Cerezuela-Espejo, V., Courel-Ibáñez, J., Morán-Navarro, R., Martínez-Cava, A., & Pallarés, J. G. (2018). The Relationship Between Lactate and Ventilatory Thresholds in Runners: Validity and Reliability of Exercise Test Performance Parameters. Frontiers in Physiology. https://doi.org/10.3389/fphys.2018.01320
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.