PhysioZoo: A Novel Open Access Platform for Heart Rate Variability Analysis of Mammalian Electrocardiographic Data
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Background: The time variation between consecutive heartbeats is commonly referred to as heart rate variability (HRV). Loss of complexity in HRV has been documented in several cardiovascular diseases and has been associated with an increase in morbidity and mortality. However, the mechanisms that control HRV are not well understood. Animal experiments are the key to investigating this question. However, to date, there are no standard open source tools for HRV analysis of mammalian electrocardiogram (ECG) data and no centralized public databases for researchers to access. Methods: We created an open source software solution specifically designed for HRV analysis from electrocardiogram (ECG) data of multiple mammals, including humans. We also created a set of public databases of mammalian ECG signals (dog, rabbit and mouse) with manually corrected R-peaks (>170,000 annotations) and signal quality annotations. The platform (software and databases) is called PhysioZoo. Results: PhysioZoo makes it possible to load ECG data and perform very accurate R-peak detection (F_1>98%). It also allows the user to manually correct the R-peak locations and annotate low signal quality of the underlying ECG. PhysioZoo implements state of the art HRV measures adapted for different mammals (dogs, rabbits, and mice) and allows easy export of all computed measures together with standard data representation figures. PhysioZoo provides databases and standard ranges for all HRV measures computed on healthy, conscious humans, dogs, rabbits and mice at rest. Study of these measures across different mammals can provide new insights into the complexity of heart rate dynamics across species. Conclusion: PhysioZoo enables the standardization and reproducibility of HRV analysis in mammalian models through its open source code, freely available software, and open access databases. PhysioZoo will support and enable new investigations in mammalian HRV research. The source code and software are available on www.physiozoo.com (available after publication).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880 · cited 1×
“…and included in PhysioZoo the classic HRV measures standardized in 1996 (Malik et al., 1996) and included other measures such as detrended fluctuation analysis (Peng et al., 1995), sample entropy (Richman and Moorman, 2000) and the recently introduced fragmentation HRV measures (Costa et al., 2017).”
MethodA Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“Numerous algorithms for finding QRS complexes in ECG signals exist and their performance has been studied (Pan and Tompkins, 1985; Llamedo and Martínez, 2014; Johnson et al., 2015).”
MethodAkselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079 · cited 1×
“For example, the typical peak in the HF band is characteristic of vagal stimulation (Akselrod et al., 1981).”
BackgroundKubios HRV–heart rate variability analysis software.
Tarvainen, M. P., Niskanen, J.-P., Lipponen, J. A., Ranta-aho, P. O., & Karjalainen, P. A. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.07.024 · Cited by 2,720
Luo, S., Michler, K., Johnston, P., & Macfarlane, P. W. (2004) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2004.08.030 · Cited by 454
A study on the optimum order of autoregressive models for heart rate variability.
Boardman, A., Schlindwein, F. S., Rocha, A. P., & Leite, A. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/2/308 · Cited by 228
Cited by
Hong, S., Zhou, Y., Shang, J., Xiao, C., & Sun, J. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103801 · Cited by 464
Levy, J., Álvarez, D., Rosenberg, A. A., Alexandrovich, A., del Campo, F., & Behar, J. A. (2021) · npj Digital Medicine · doi:10.1038/s41746-020-00373-5 · Cited by 125
Self-citationRemote health monitoring and diagnosis in the time of COVID-19
Behar, J. A., Liu, C., Kotzen, K., Tsutsui, K., Corino, V. D. A., Singh, J., Pimentel, M. A. F., Warrick, P., Zaunseder, S., Andreotti, F., et al. (2020) · arXiv · doi:10.48550/arxiv.2005.08537 · Cited by 86
Self-citationRemote health diagnosis and monitoring in the time of COVID-19
Behar, J. A., Liu, C., Kotzen, K., Tsutsui, K., Corino, V. D. A., Singh, J., Pimentel, M. A. F., Warrick, P., Zaunseder, S., Andreotti, F., et al. (2020) · Physiological Measurement · doi:10.1088/1361-6579/abba0a · Cited by 86
Self-citationMoen, J. M., Matt, M. G., Ramirez, C., Tarasov, K. V., Chakir, K., Tarasova, Y. S., Lukyanenko, Y., Tsutsui, K., Monfredi, O., Morrell, C. H., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00615 · Cited by 51
Self-citationPupil size reveals arousal level fluctuations in human sleep
Carro-Domínguez, M., Huwiler, S., Oberlin, S., Oesch, T. L., Badii, G., Lüthi, A., Wenderoth, N., Meissner, S. N., & Lustenberger, C. (2025) · Nature Communications · doi:10.1038/s41467-025-57289-5 · Cited by 41
Karunanithi, Z., Jegatheeswaran, A., Goodfellow, S. D., Dixon, W., Hjortdal, V. E., Eytan, D., & Mazwi, M. L. (2022) · International Journal of Cardiology Congenital Heart Disease · doi:10.1016/j.ijcchd.2022.100333 · Cited by 7
Metadata
- Authors
- Behar, J. A., Rosenberg, A. A., Weiser-Bitoun, I., Shemla, O., Alexandrovich, A., Konyukhov, E., & Yaniv, Y.
- Venue
- Frontiers in Physiology
- Publisher
- Frontiers Media SA
- Published
- 2018-10-04
- Volume
- 9
- Pages
- 1390-1390
- ISSN
- 1664-042X (ISSN-L)
- OpenAlex
- W2895333514
- Cited by
- 118
- References
- 7
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.