The DOI matches its Crossref record; 229 of the 229 references it cites were found in a registry or an index.
Photoplethysmogram Analysis and Applications: An Integrative Review
Open accessAbstract
Beyond its use in a clinical environment, photoplethysmogram (PPG) is increasingly used for measuring the physiological state of an individual in daily life. This review aims to examine existing research on photoplethysmogram concerning its generation mechanisms, measurement principles, clinical applications, noise definition, pre-processing techniques, feature detection techniques, and post-processing techniques for photoplethysmogram processing, especially from an engineering point of view. We performed an extensive search with the PubMed, Google Scholar, Institute of Electrical and Electronics Engineers (IEEE), ScienceDirect, and Web of Science databases. Exclusion conditions did not include the year of publication, but articles not published in English were excluded. Based on 118 articles, we identified four main topics of enabling PPG: (A) PPG waveform, (B) PPG features and clinical applications including basic features based on the original PPG waveform, combined features of PPG, and derivative features of PPG, (C) PPG noise including motion artifact baseline wandering and hypoperfusion, and (D) PPG signal processing including PPG preprocessing, PPG peak detection, and signal quality index. The application field of photoplethysmogram has been extending from the clinical to the mobile environment. Although there is no standardized pre-processing pipeline for PPG signal processing, as PPG data are acquired and accumulated in various ways, the recently proposed machine learning-based method is expected to offer a promising solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–229 of 229
Development of a new analgesic index using nasal photoplethysmography
Choi, B., Park, C., Lee, Y. H., Shin, H., Lee, S. H., Jeong, S., Noh, G., & Lee, B. (2018) · Anaesthesia · doi:10.1111/anae.14327 · Cited by 27
Self-citationTEMPERATURE DEPENDENCE OF LED AND ITS THEORETICAL EFFECT ON PULSE OXIMETRY
Reynolds, K. J., de Kock, J. P., Tarassenko, L., & Moyle, J. (1991) · British Journal of Anaesthesia · doi:10.1093/bja/67.5.638 · Cited by 26
Yuan, H., Memon, S. F., Newe, T., Lewis, E., & Leen, G. (2017) · Measurement · doi:10.1016/j.measurement.2017.10.060 · Cited by 25
Song, J., Li, D., Ma, X., Teng, G., & Wei, J. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.05.020 · Cited by 25
Freckmann, G., Pleus, S., Haug, C., Bitton, G., & Nagar, R. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600407 · Cited by 24
Peripheral Hemodynamics Evaluated by Acceleration Plethysmography in Workers Exposed to Lead.
Aiba, Y., Ohshiba, S., Horiguchi, S., Morioka, I., Miyashita, K., Kiyota, I., Endo, G., Takada, H., & Iwata, H. (1999) · Industrial Health · doi:10.2486/indhealth.37.3 · Cited by 23
Multivariate classification of systemic vascular resistance using photoplethysmography
Lee, Q. Y., Chan, G. S. H., Redmond, S. J., Middleton, P. M., Steel, E., Malouf, P. J., Critoph, C., Flynn, G. M., O’Lone, E., & Lovell, N. H. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/8/008 · Cited by 23
McCombie, D. B., Asada, H. H., & Reisner, A. T. (2005) · doi:10.1109/iembs.2005.1617231 · Cited by 22
Kim, J., Lee, T., Kim, J.-H., & Ko, H. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319867 · Cited by 22
A Driver’s Physiological Monitoring System Based on a Wearable PPG Sensor and a Smartphone
Lin, Y., Lin, C.-F., & You, H.-Z. (2011) · Communications in computer and information science · doi:10.1007/978-3-642-23948-9_36 · Cited by 20
Robust peak detection of pulse waveform using height ratio
Xu, L., Meng, M. Q. ‐., Liu, R., & Wang, K. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650051 · Cited by 20
Krishnan, R., Natarajan, B., & Warren, S. (2008) · International Conference on Computer Communications and Networks (ICCCN) · doi:10.1109/icccn.2008.ecp.71 · Cited by 20
Changes in the Photoplethysmogram Waveform After Exercise
Poon, C. C. Y., Teng, X. F., Wong, Y. M., Zhang, C., & Zhang, Y. (2006) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmd.2004.1689576 · Cited by 19
Pintavirooj, C., Ni, B., Chatkobkool, C., & Pinijkij, K. (2021) · Healthcare · doi:10.3390/healthcare9060647 · Cited by 19
Liu, J., Li, Y., Ding, X., Dai, W., & Zhang, Y. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319752 · Cited by 18
Noninvasive monitoring of peripheral perfusion
Lima, A. A. P., & Bakker, J. (2007) · Springer eBooks · doi:10.1007/3-540-37363-2_26 · Cited by 18
Relation of local skin temperature and local sweating to cutaneous blood flow
Senay, L. C., Prokop, L. D., Cronau, L. H., et al. (1963) · Journal of Applied Physiology · doi:10.1152/jappl.1963.18.4.781 · Cited by 17
SISTEMIC, F. D. I., Rojano, J. F., & Isaza, C. (2016) · International Journal of Signal Processing Systems · doi:10.18178/ijsps.4.6.475-482 · Cited by 15
The Optimal Attachment Position for a Fingertip Photoplethysmographic Sensor With Low DC
Lee, C., Shin, H., Park, J., & Lee, M. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2164904 · Cited by 13
Self-citationA Novel AMARS Technique for Baseline Wander Removal Applied to Photoplethysmogram
Timimi, A. A. K., Ali, M. A. M., & Chellappan, K. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2649940 · Cited by 12
Stern, R. M. (1974) · Psychophysiology · doi:10.1111/j.1469-8986.1974.tb00824.x · Cited by 10
Assessment of changes in arterial compliance by photoplethysmography
Nitzan, M., Babchenko, A., Faib, I., Davidson, E. M., & Adler, D. (2002) · IEEE Convention of Electrical and Electronics Engineers in Israel · doi:10.1109/eeei.2000.924425 · Cited by 9
A New Reflectance Pulse Oximeter Housing to Reduce Contact Pressure Effects
Dresher, R. P., & Mendelson, Y. (2006) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.2006.1629746 · Cited by 8
Noninvasive Assistive Method to Diagnose Arterial Disease-Takayasu’s Arteritis
Lakshmanan, S., Chatterjee, D., & Manivannan, M. (2018) · Lecture notes in computational vision and biomechanics · doi:10.1007/978-3-319-71767-8_32 · Cited by 7
Roy, M. S., Bag, P., & Gupta, R. (2019) · IEEE Region 10 Symposium (TENSYMP) · doi:10.1109/tensymp46218.2019.8971035 · Cited by 7
Spīgulis, J., Gailite, L., & Lihachev, A. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.724071 · Cited by 6
Foo, J. Y. A. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/9/n01 · Cited by 5
Pre-processing of Photoplethysmographic Waveform for Amplitude Regularization
Kim, J., Lee, J., & Shin, H. (2019) · Journal of Electrical Engineering and Technology · doi:10.1007/s42835-019-00185-y · Cited by 5
Self-citationBohusch, T., Miller, T., Kreamer, W., Eisenhardt, J. R., & Foehl, H. C. (1994) · Cardiopulmonary Physical Therapy Journal · doi:10.1097/01823246-199405020-00004 · Cited by 1
Cited by
A PPG Signal Dataset Collected in Semi-Naturalistic Settings Using Galaxy Watch
Park, S., Zheng, D., & Lee, U. (2025) · Scientific Data · doi:10.1038/s41597-025-05152-z · Cited by 12
Metadata
- Authors
- Park, J., Seok, H. S., Kim, S.-S., & Shin, H.
- Venue
- Frontiers in Physiology
- Publisher
- Frontiers Media SA
- Published
- 2022-03-01
- Volume
- 12
- Pages
- 808451-808451
- ISSN
- 1664-042X (ISSN-L)
- OpenAlex
- W4214602270
- Cited by
- 422
- References
- 229
- FWCI
- 21.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.