Cited by 12Non-Invasive Vital Sign MonitoringHeart Rate Variability and Autonomic ControlEmotion and Mood Recognition

A PPG Signal Dataset Collected in Semi-Naturalistic Settings Using Galaxy Watch

Open access
Park, Sangjun, Zheng, Dejiang, Lee, Uichin·2025·Scientific Data

Abstract

The widespread adoption of consumer-grade wearable devices, such as Galaxy Watch, has revolutionized personal health monitoring as they enable continuous and non-invasive measurement of key cardiovascular indicators through photoplethysmography (PPG) sensors. However, existing datasets primarily rely on research-grade devices, limiting the applicability of consumer-grade wearables in real-world conditions. To address this gap, this study presents GalaxyPPG, a dataset collected from 24 participants that includes wrist-worn PPG signals from a Galaxy Watch 5 and an Empatica E4, alongside chest-worn ECG data from a Polar H10. Data were captured during diverse activities in a semi-naturalistic setting, providing insights into the sensing performance of consumer-grade wearables under motion- or stress-inducing activities. This dataset is designed to advance applications of PPG signals, such as HR tracking with diverse physical activities and HRV monitoring for stress detection. Additionally, we offer an open-source toolkit for data collection and analysis using Samsung Galaxy Watch, fostering reproducibility and further research leveraging this toolkit.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41597-025-05152-z

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Wearables may skip readings entirely when quality drops below internal thresholds, effectively masking rather than mitigating error.

    “In some cases, wearables may even skip readings entirely when quality drops below internal thresholds, effectively masking rather than mitigating error [32].”

    From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [32]

    The Technical Validation section (Dataset Completeness Analysis; page unavailable) reports missing Galaxy Watch heart-rate measurements and says its internal status codes identify periods when the device deemed heart-rate calculations unreliable. It does not establish that readings were skipped because signal quality fell below an internal threshold, or characterize the missing readings as masking rather than mitigating error. (LLM, conf=0.85)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. [39]Elgendi, M., Jonkman, M. & De Boer, F. Frequency bands effects on qrs detection. Biosignals 2003, 2002 (2010).

Cited by

Sorted by citations

Authors
Park, S., Zheng, D., & Lee, U.
Affiliations
Korea Advanced Institute of Science and Technology (KR)
Corresponding author
Lee, Uichin
Venue
Scientific Data
Published
2025-05-28
Volume
12
Issue
1
Pages
892-892
ISSN
2052-4463 (ISSN-L)
OpenAlex
W4410822879
Cited by
12
References
40
Citations by year
2026: 10 · 2025: 2
Type
data paper
Language
en
Open access
Locations
  • Scientific Data (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
National Research Foundation of Korea (2022R1A2C2011536)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Emotion and Mood Recognition
Keywords
photoplethysmography, consumer-grade wearable devices, heart rate monitoring, heart rate variability, stress detection, physical activity, motion artifacts
MeSH terms
Wearable Electronic Devices, Electrocardiography, Heart Rate, Humans, Photoplethysmography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review