The DOI matches its Crossref record; 229 of the 229 references it cites were found in a registry or an index.
Photoplethysmogram Analysis and Applications: An Integrative Review
Open accessAbstract
Beyond its use in a clinical environment, photoplethysmogram (PPG) is increasingly used for measuring the physiological state of an individual in daily life. This review aims to examine existing research on photoplethysmogram concerning its generation mechanisms, measurement principles, clinical applications, noise definition, pre-processing techniques, feature detection techniques, and post-processing techniques for photoplethysmogram processing, especially from an engineering point of view. We performed an extensive search with the PubMed, Google Scholar, Institute of Electrical and Electronics Engineers (IEEE), ScienceDirect, and Web of Science databases. Exclusion conditions did not include the year of publication, but articles not published in English were excluded. Based on 118 articles, we identified four main topics of enabling PPG: (A) PPG waveform, (B) PPG features and clinical applications including basic features based on the original PPG waveform, combined features of PPG, and derivative features of PPG, (C) PPG noise including motion artifact baseline wandering and hypoperfusion, and (D) PPG signal processing including PPG preprocessing, PPG peak detection, and signal quality index. The application field of photoplethysmogram has been extending from the clinical to the mobile environment. Although there is no standardized pre-processing pipeline for PPG signal processing, as PPG data are acquired and accumulated in various ways, the recently proposed machine learning-based method is expected to offer a promising solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939
Zijlstra, W. G., Buursma, A., & Meeuwsen-van der Roest, W. P. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.9.1633 · Cited by 665
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661 · cited 1×
“However, it was reported that PRV could be differ from HRV under dynamic conditions, such as exercise or mental stress conditions (Schäfer and Vagedes, 2013; Mejía-Mejía et al., 2020).”
BackgroundDetermination of age-related increases in large artery stiffness by digital pulse contour analysis
MILLASSEAU, S. C., KELLY, R. P., RITTER, J. M., & CHOWIENCZYK, P. J. (2002) · Clinical Science · doi:10.1042/cs1030371 · Cited by 613
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589
Remote Heart Rate Measurement from Face Videos under Realistic Situations
Li, X., Chen, J., Zhao, G., & Pietikainen, M. (2014) · 2014 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2014.543 · Cited by 550
Mobile Photoplethysmographic Technology to Detect Atrial Fibrillation
Guo, Y., Wang, H., Zhang, H., Liu, T., Liang, Z., Xia, Y., Yan, L., Xing, Y., Shi, H., Li, S., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.08.019 · Cited by 489
Multiparameter Respiratory Rate Estimation From the Photoplethysmogram
Karlen, W., Raman, S., Ansermino, J. M., & Dumont, G. A. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2246160 · Cited by 485
Pulse oximetry: Principles and limitations
Sinex, J. E. (1999) · The American Journal of Emergency Medicine · doi:10.1016/s0735-6757(99)90019-0 · Cited by 481
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Gil, E., Orini, M., Bailón, R., Vergara, J. M., Mainardi, L., & Laguna, P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/015 · Cited by 461
An Efficient Algorithm for Automatic Peak Detection in Noisy Periodic and Quasi-Periodic Signals
Scholkmann, F., Boss, J., & Wolf, M. (2012) · Algorithms · doi:10.3390/a5040588 · Cited by 453
(1997) · Institute of Physics eBooks · doi:10.1887/0750304677 · Cited by 453
Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate
Shelley, K. H. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269512.82836.c9 · Cited by 450
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 447
Pulse oximetry: fundamentals and technology update
Nitzan, M., Romem, A., & Koppel, R. (2014) · Medical Devices: Evidence and Research · doi:10.2147/mder.s47319 · Cited by 438
Chen, W., Kobayashi, T., Ichikawa, S., Takeuchi, Y., & Togawa, T. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345755 · Cited by 425
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B. S., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 399
Deep PPG: Large-Scale Heart Rate Estimation with Convolutional Neural Networks
Reiss, A., Indlekofer, I., Schmidt, P., & Van Laerhoven, K. (2019) · Sensors · doi:10.3390/s19143079 · Cited by 377
Cuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time
Poon, C. C. Y., & Zhang, Y. T. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1615827 · Cited by 375
Orphanidou, C., Bonnici, T., Charlton, P., Clifton, D., Vallance, D., & Tarassenko, L. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2338351 · Cited by 368
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 366
Contour analysis of the photoplethysmographic pulse measured at the finger
Millasseau, S. C., Ritter, J. M., Takazawa, K., & Chowienczyk, P. J. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000239277.05068.87 · Cited by 354
Skin photoplethysmography — a review
Kamal, A. A. R., Harness, J. B., Irving, G., & Mearns, A. J. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90159-4 · Cited by 328 · cited 1×
“The volume of blood volume in the measurement site, arterial diameter, hemoglobin concentration, and hemoglobin direction according to the cardiac cycle are also major factors that affect the detected light intensity (De Trafford and Lafferty, 1984; Kamal et al., 1989; Lindberg and Oberg, 1993).”
BackgroundOptimal Signal Quality Index for Photoplethysmogram Signals
Elgendi, M. (2016) · Bioengineering · doi:10.3390/bioengineering3040021 · Cited by 320
Photoplethysmography based atrial fibrillation detection: a review
Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0207-9 · Cited by 300
Accurate Heart Rate Monitoring During Physical Exercises Using PPG
Temko, A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2676243 · Cited by 293
Alian, A. A., & Shelley, K. H. (2014) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2014.08.006 · Cited by 289
Biswas, D., Everson, L., Liu, M., Panwar, M., Verhoef, B.-E., Patki, S., Kim, C. H., Acharyya, A., Van Hoof, C., Konijnenburg, M., et al. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2892297 · Cited by 288
Lu, S., Zhao, H., Ju, K., Shin, K., Lee, M., Shelley, K., & Chon, K. H. (2008) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9103-y · Cited by 284
Modified Beer-Lambert law for blood flow
Baker, W. B., Parthasarathy, A. B., Busch, D. R., Mesquita, R. C., Greenberg, J. H., & Yodh, A. G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004053 · Cited by 283
Emotion Based Music Recommendation System Using Wearable Physiological Sensors
Ayata, D., Yaslan, Y., & Kamasak, M. E. (2018) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2018.2844736 · Cited by 280
Dynamic time warping and machine learning for signal quality assessment of pulsatile signals
Li, Q., & Clifford, G. D. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/9/1491 · Cited by 274
Bortolotto, L. A., Blacher, J., Kondo, T., Takazawa, K., & Safar, M. E. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(99)00192-2 · Cited by 273
PP-Net: A Deep Learning Framework for PPG-Based Blood Pressure and Heart Rate Estimation
Panwar, M., Gautam, A., Biswas, D., & Acharyya, A. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2990864 · Cited by 237
Blood pressure estimation from appropriate and inappropriate PPG signals using A whole-based method
Mousavi, S. S., Firouzmand, M., Charmi, M., Hemmati, M., Moghadam, M., & Ghorbani, Y. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.08.022 · Cited by 233
The peripheral pulse wave: Information overlooked
Murray, W. B., & Foster, P. A. (1996) · Journal of Clinical Monitoring · doi:10.1007/bf02077634 · Cited by 232
Development and Evaluation of an Ambulatory Stress Monitor Based on Wearable Sensors
Choi, J., Ahmed, B., & Gutierrez-Osuna, R. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2169804 · Cited by 221
Adaptive threshold method for the peak detection of photoplethysmographic waveform
Shin, H. S., Lee, C., & Lee, M. (2009) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2009.10.006 · Cited by 210
Self-citationDesigning ECG monitoring healthcare system with federated transfer learning and explainable AI
Raza, A., Tran, K. P., Koehl, L., & Li, S. (2022) · Knowledge-Based Systems · doi:10.1016/j.knosys.2021.107763 · Cited by 205
Ding, X., Yan, B. P., Zhang, Y.-T., Liu, J., Zhao, N., & Tsang, H. K. (2017) · Scientific Reports · doi:10.1038/s41598-017-11507-3 · Cited by 197
Wong, M. Y.-M., Poon, C. C.-Y., & Zhang, Y.-T. (2009) · Cardiovascular Engineering · doi:10.1007/s10558-009-9070-7 · Cited by 191
Predicting Arterial Stiffness From the Digital Volume Pulse Waveform
Alty, S. R., Angarita-Jaimes, N., Millasseau, S. C., & Chowienczyk, P. J. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897805 · Cited by 190
Motion-tolerant magnetic earring sensor and wireless earpiece for wearable photoplethysmography
Poh, M.-Z., Swenson, N. C., & Picard, R. W. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2042607 · Cited by 189
Cannesson, M., Besnard, C., Durand, P. G., Bohé, J., & Jacques, D. (2005) · Critical Care · doi:10.1186/cc3799 · Cited by 186
Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
Allen, J., & Murray, A. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001478 · Cited by 179
Continuous noninvasive blood pressure measurement by pulse transit time
Fung, P., Dumont, G., Ries, C., Mott, C., & Ansermino, M. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1403264 · Cited by 175
Mejía-Mejía, E., Budidha, K., Abay, T. Y., May, J. M., & Kyriacou, P. A. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00779 · Cited by 171
Zimmermann, M., Feibicke, T., Keyl, C., Prasser, C., Moritz, S., Graf, B. M., & Wiesenack, C. (2010) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e328335fbd1 · Cited by 167
Signal quality measures for pulse oximetry through waveform morphology analysis
Sukor, J. A., Redmond, S. J., & Lovell, N. H. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/3/008 · Cited by 166
Reddy, K. A., George, B., & Kumar, V. J. (2009) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2008.2009136 · Cited by 165
Influence of skin type and wavelength on light wave reflectance
Fallow, B. A., Tarumi, T., & Tanaka, H. (2013) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-013-9436-7 · Cited by 162
PHOTO-ELECTRIC PLETHYSMOGRAPHY AS A MONITORING DEVICE IN ANAESTHESIA
DORLAS, J. C., & NIJBOER, J. A. (1985) · British Journal of Anaesthesia · doi:10.1093/bja/57.5.524 · Cited by 160
Struys, M. M. R. F., Vanpeteghem, C. M., Huiku, M., Uutela, K., Blyaert, N. B. K., & Mortier, E. P. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem173 · Cited by 156
El-Hajj, C., & Kyriacou, P. A. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102301 · Cited by 156
Assessment of Non-Invasive Blood Pressure Prediction from PPG and rPPG Signals Using Deep Learning
Schrumpf, F., Frenzel, P., Aust, C., Osterhoff, G., & Fuchs, M. (2021) · Sensors · doi:10.3390/s21186022 · Cited by 154
Lee, J., Kim, M., Park, H.-K., & Kim, I. Y. (2020) · Sensors · doi:10.3390/s20051493 · Cited by 153
Deep learning enables sleep staging from photoplethysmogram for patients with suspected sleep apnea
Korkalainen, H., Aakko, J., Duce, B., Kainulainen, S., Leino, A., Nikkonen, S., Afara, I. O., Myllymaa, S., Töyräs, J., & Leppänen, T. (2020) · SLEEP · doi:10.1093/sleep/zsaa098 · Cited by 153
Secondary Peak Detection of PPG Signal for Continuous Cuffless Arterial Blood Pressure Measurement
He, X., Goubran, R. A., & Liu, X. P. (2014) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2014.2299524 · Cited by 149
Evaluation of wearable consumer heart rate monitors based on photopletysmography
Parak, J., & Korhonen, I. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944419 · Cited by 148
Liu, J., Yan, B. P., Zhang, Y., Ding, X., Su, P., & Zhao, N. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2874957 · Cited by 147
Shin, H., & Min, S. D. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0302-y · Cited by 145
Self-citationA Real Time Analysis of PPG Signal for Measurement of SpO2 and Pulse Rate
Bagha, S., & Shaw, L. (2011) · International Journal of Computer Applications · Cited by 143
Proesmans, T., Mortelmans, C., Haelst, R. V., Verbrugge, F. H., Vandervoort, P. M., & Vaes, B. (2018) · JMIR mhealth and uhealth · doi:10.2196/12284 · Cited by 143
A Biophysically‐Based Spectral Model of Light Interaction with Human Skin
Krishnaswamy, A., & Baranoski, G. V. G. (2004) · Computer Graphics Forum · doi:10.1111/j.1467-8659.2004.00764.x · Cited by 140
Cuffless blood pressure estimation from PPG signals and its derivatives using deep learning models
El-Hajj, C., & Kyriacou, P. A. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102984 · Cited by 140
Muehlsteff, J., Aubert, X. L., & Schuett, M. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260275 · Cited by 139
The relationship between the photoplethysmographic waveform and systemic vascular resistance
Alian, A. A., Haddadin, A. S., Tantawy, H., Badr, T., Stout, R. G., Silverman, D. G., & Shelley, K. H. (2007) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9097-5 · Cited by 136
von Wowern, E., Östling, G., Nilsson, P. M., & Olofsson, P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0135659 · Cited by 134
Explainable artificial intelligence to detect atrial fibrillation using electrocardiogram
Jo, Y., Cho, Y., Lee, S. Y., Kwon, J., Kim, K., Jeon, K., Cho, S., Park, J., & Oh, B. (2020) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.11.053 · Cited by 132
Self-citationAssessing mental stress from the photoplethysmogram: a numerical study
Charlton, P. H., Celka, P., Farukh, B., Chowienczyk, P., & Alastruey, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aabe6a · Cited by 131
Wang, G., Atef, M., & Lian, Y. (2018) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2018.2849261 · Cited by 130
The analysis of PPG morphology: Investigating the effects of aging on arterial compliance
Yousef, Q., Reaz, M. B. I., & Ali, M. A. M. (2012) · Measurement Science Review · doi:10.2478/v10048-012-0036-3 · Cited by 126
Photoplethysmogram signal quality estimation using repeated Gaussian filters and cross-correlation
Karlen, W., Kobayashi, K., Ansermino, J. M., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/10/1617 · Cited by 123
Diagnostic assessment of a deep learning system for detecting atrial fibrillation in pulse waveforms
Poh, M., Poh, Y. C., Chan, P., Wong, C., Pun, L., Leung, W. W., Wong, Y., Wong, M. M., Chu, D. W., & Siu, C. (2018) · Heart · doi:10.1136/heartjnl-2018-313147 · Cited by 123
Body Sensor Network for Mobile Health Monitoring, a Diagnosis and Anticipating System
Wannenburg, J., & Malekian, R. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2464773 · Cited by 122
Seitsonen, E. R. J., Korhonen, I. K. J., Van Gils, M. J., Huiku, M., Lötjönen, J. M. P., Korttila, K. T., & Yli‐Hankala, A. M. (2005) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2005.00654.x · Cited by 120
Statistical approach for the detection of motion/noise artifacts in Photoplethysmogram
Selvaraj, N., Mendelson, Y., Shelley, K. H., Silverman, D. G., & Chon, K. H. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091232 · Cited by 119
Ruggiero, E., Castro, S. A., Habtemariam, A., et al. (2016) · Dalton Transactions · doi:10.1039/c6dt01428c · Cited by 119
Imanaga, I., Hara, H., KOYANAGI, S., & TANAKA, K. (1998) · Japanese Heart Journal · doi:10.1536/ihj.39.775 · Cited by 118
Noninvasive cardiac output estimation using a novel photoplethysmogram index
Wang, L., Pickwell‐MacPherson, E., Liang, Y. P., & Zhang, Y. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333091 · Cited by 117
Fast Emotion Recognition Based on Single Pulse PPG Signal with Convolutional Neural Network
Lee, M. S., Lee, Y. K., Pae, D.-S., Lim, M. T., Kim, D.-W., & Kang, T. (2019) · Applied Sciences · doi:10.3390/app9163355 · Cited by 117
SleepAp: An Automated Obstructive Sleep Apnoea Screening Application for Smartphones
Behar, J. A., Roebuck, A., Shahid, M., Daly, J., Hallack, A., Palmius, N., Stradling, J. R., & Clifford, G. D. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2307913 · Cited by 115
Photoplethysmography and nociception
Korhonen, I., & Yli‐Hankala, A. (2009) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2009.02026.x · Cited by 110
Multi-wavelength photoplethysmography method for skin arterial pulse extraction
Liu, J., Yan, B. P.-Y., Dai, W.-X., Ding, X.-R., Zhang, Y.-T., & Zhao, N. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.004313 · Cited by 107
Otsuka, T., Kawada, T., Katsumata, M., & Ibuki, C. (2006) · Circulation Journal · doi:10.1253/circj.70.304 · Cited by 107
The vascular impact of aging andvasoactive drugs: comparison of twodigital volume pulse measurements
Millasseau, S. (2003) · American Journal of Hypertension · doi:10.1016/s0895-7061(03)00569-7 · Cited by 103
Effect of skin pigmentation on pulse oximetry accuracy in the emergency department
Adler, J. N., Hughes, L. A., Vtvilecchia, R., & Jr., C. A. C. (1998) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.1998.tb02772.x · Cited by 102
Optical properties of blood in motion
Lindberg, L.-G., & Oberg, P. A. (1993) · Optical Engineering · doi:10.1117/12.60688 · Cited by 102
Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography
Han, H., Kim, M.-J., & Kim, J. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352596 · Cited by 101
What Is the Best Site for Measuring the Effect of Ventilation on the Pulse Oximeter Waveform?
Shelley, K. H., Jablonka, D. H., Alian, A. A., Stout, R. G., Rezkanna, H., & Silverman, D. G. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000222477.67637.17 · Cited by 99
Spīgulis, J., Gailite, L., Lihachev, A., & Erts, R. (2007) · Applied Optics · doi:10.1364/ao.46.001754 · Cited by 98
Detection and Classification of Sleep Apnea and Hypopnea Using PPG and SpO$_2$ Signals
Lazazzera, R., Deviaene, M., Varon, C., Buyse, B., Testelmans, D., Laguna, P., Gil, E., & Carrault, G. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3028041 · Cited by 98
An Algorithm for Real-Time Pulse Waveform Segmentation and Artifact Detection in Photoplethysmograms
Fischer, C., Dömer, B., Wibmer, T., & Penzel, T. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2518202 · Cited by 97
Explainable Deep Learning-Based Approach for Multilabel Classification of Electrocardiogram
Ganeshkumar, M., Ravi, V., Sowmya, V., Gopalakrishnan, E. A., & Soman, K. P. (2021) · IEEE Transactions on Engineering Management · doi:10.1109/tem.2021.3104751 · Cited by 97
Surgical stress index reflects surgical stress in gynaecological laparoscopic day-case surgery †
Ahonen, J., Jokela, R., Uutela, K., & Huiku, M. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem035 · Cited by 96
Smart technologies toward sleep monitoring at home
Park, K. S., & Choi, S. H. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-018-0091-2 · Cited by 96
A Real-time PPG Quality Assessment Approach for Healthcare Internet-of-Things
Naeini, E. K., Azimi, I., Rahmani, A. M., Liljeberg, P., & Dutt, N. D. (2019) · Procedia Computer Science · doi:10.1016/j.procs.2019.04.074 · Cited by 94
Photoplethysmogram (PPG) signal analysis and wavelet de-noising
Joseph, G., Joseph, A., Titus, G., Thomas, R. M., & Jose, D. (2014) · Annual International Conference on Emerging Research Areas and International Conference on Microelectronics, Communications and Renewable Energy · doi:10.1109/aicera.2014.6908199 · Cited by 93
Allen, J., & Murray, A. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/3/303 · Cited by 93
Gehring, H., Hornberger, C., Matz, H., Konecny, E., & Schmucker, P. (2002) · Respiratory Care · doi:10.1177/002013240204700105 · Cited by 92
Landsverk, S. A., Høiseth, L. Ø., Kvandal, P., Hisdal, J., Skare, Ø., & Kirkebøen, K. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181895f9f · Cited by 92
Kwon, S., Hong, J., Choi, E., Lee, E., Hostallero, D. E., Kang, W. J., Lee, B., Jeong, E., Koo, B., Oh, S., et al. (2019) · JMIR mhealth and uhealth · doi:10.2196/12770 · Cited by 90
Lee, S., Chu, Y., Ryu, J., Park, Y. J., Yang, S., & Koh, S. B. (2022) · Yonsei Medical Journal · doi:10.3349/ymj.2022.63.s93 · Cited by 88
The absence of vasoconstrictor reflexes in the forehead circulation. Effects of cold
Hertzman, A. B., & Roth, L. W. (1942) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1942.136.4.692 · Cited by 85
A Robust Pulse Onset and Peak Detection Method for Automated PPG Signal Analysis System
Vadrevu, S., & Manikandan, M. S. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2857878 · Cited by 85
Learning Your Heart Actions From Pulse: ECG Waveform Reconstruction From PPG
Zhu, Q., Tian, X., Wong, C.-W., & Wu, M. H. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3097946 · Cited by 85
Venema, B., Blanik, N., Blažek, V., Gehring, H., Opp, A., & Leonhardt, S. K. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2196276 · Cited by 81
Nabeel, P. M., Jayaraj, J., & Sivaprakasam, M. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa9550 · Cited by 80
Variability of photoplethysmographyperipheral pulse measurementsat the ears, thumbs and toes
Allen, J., & Murray, A. (2000) · IEE Proceedings - Science Measurement and Technology · doi:10.1049/ip-smt:20000846 · Cited by 79
Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure
Masè, M., Mattei, W., Cucino, R., Faes, L., & Nollo, G. (2011) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2010.11.019 · Cited by 78
The form of the volume pulse in the finger pad in health, arteriosclerosis, and hypertension
Dillon, J. B., & Hertzman, A. B. (1941) · American Heart Journal · doi:10.1016/s0002-8703(41)90966-3 · Cited by 77
Using PPG Signals and Wearable Devices for Atrial Fibrillation Screening
Yang, C., Veiga, C., Rodriguez-Andina, J. J., Fariña, J., Íñiguez, A., & Yin, S. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2889614 · Cited by 77
Foo, J. Y. A., & Wilson, S. J. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-005-0008-y · Cited by 75
Ding, X., & Zhang, Y. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318383 · Cited by 73
Assessment of deep learning based blood pressure prediction from PPG and rPPG signals
Schrumpf, F., Frenzel, P., Aust, C., Osterhoff, G., & Fuchs, M. (2021) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw53098.2021.00423 · Cited by 73
Evaluation of perfusion index as a tool for pain assessment in critically ill patients
Hasanin, A. M., Mohamed, S. A. R., & El-adawy, A. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9936-3 · Cited by 72
Atrial fibrillation detection from raw photoplethysmography waveforms: A deep learning application
Aschbacher, K., Yilmaz, D., Kerem, Y., Crawford, S. L., Benaron, D. A., Liu, J., Eaton, M., Tison, G. H., Olgin, J. E., Li, Y., et al. (2020) · Heart Rhythm O2 · doi:10.1016/j.hroo.2020.02.002 · Cited by 72
Prediction of vascular aging based on smartphone acquired PPG signals
Dall’Olio, L., Curti, N., Remondini, D., Harb, Y. S., Asselbergs, F. W., Castellani, G., & Uh, H. (2020) · Scientific Reports · doi:10.1038/s41598-020-76816-6 · Cited by 72
Allen, J., Liu, H., Iqbal, S., Zheng, D., & Stansby, G. P. (2021) · Physiological Measurement · doi:10.1088/1361-6579/abf9f3 · Cited by 72
Emotion detection and recognition using HRV features derived from photoplethysmogram signals
Rakshit, R., Reddy, V. R., & Deshpande, P. (2016) · doi:10.1145/3009960.3009962 · Cited by 71
Estimation of respiration rate from ECG, BP and PPG signals using empirical mode decomposition
Madhav, K. V., Ram, M. R., Krishna, E. H., Komalla, N. R., & Reddy, K. A. (2011) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/imtc.2011.5944249 · Cited by 70
CEFEs: A CNN Explainable Framework for ECG Signals
Maweu, B. M., Dakshit, S., Shamsuddin, R., & Prabhakaran, B. (2021) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2021.102059 · Cited by 70
Optical Techniques in the Assessment of Peripheral Arterial Disease
Alnaeb, M. E., Alobaid, N., Seifalian, A. M., Mikhailidis, D. P., & Hamilton, G. (2006) · Current Vascular Pharmacology · doi:10.2174/157016107779317242 · Cited by 69
Arterial stiffness indices in healthy volunteers using non‐invasive digital photoplethysmography
Brillante, D., O’Sullivan, A., & Howes, L. G. (2008) · Blood Pressure · doi:10.1080/08037050802059225 · Cited by 68
Identification of Atrial Fibrillation by Quantitative Analyses of Fingertip Photoplethysmogram
Tang, S., Huang, P.-W., Hung, C., Shan, S.-M., Lin, Y., Shieh, J.-S., Lai, D., Wu, A.-Y. A., & Jeng, J. (2017) · Scientific Reports · doi:10.1038/srep45644 · Cited by 68
Continuous Blood Pressure Monitoring using ECG and Finger Photoplethysmogram
Chua, C. P., & Heneghan, C. (2006) · Conference proceedings · doi:10.1109/iembs.2006.259612 · Cited by 66
What does photoplethysmography measure?
de Trefford, J., & Lafferty, K. (1984) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447713 · Cited by 66
A Deep Learning Approach to Predict Blood Pressure from PPG Signals
Tazarv, A., & Levorato, M. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629687 · Cited by 66
Allen, J., & Murray, A. (1993) · Physiological Measurement · doi:10.1088/0967-3334/14/1/003 · Cited by 65
Enhancing the estimation of blood pressure using pulse arrival time and two confounding factors
Baek, H. J., Kim, K. K., Kim, J. S., Lee, B., & Park, K. S. (2009) · Physiological Measurement · doi:10.1088/0967-3334/31/2/002 · Cited by 64
Bentham, M., Stansby, G. P., & Allen, J. (2018) · Diseases · doi:10.3390/diseases6030081 · Cited by 64
A non-invasive measure of changes in blood flow in the human anterior tibial muscle
Zhang, Q., Lindberg, L., Kadefors, R., & STYF, J. R. (2001) · European Journal of Applied Physiology · doi:10.1007/s004210100413 · Cited by 63
Kyriacou, P. A., Powell, S., Langford, R. M., & Jones, D. P. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/3/305 · Cited by 63
Detecting Atrial Fibrillation and Atrial Flutter in Daily Life Using Photoplethysmography Data
Eerikäinen, L. M., Bonomi, A., Schipper, F., Dekker, L., de Morree, H. M., Vullings, R., & Aarts, R. M. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2950574 · Cited by 63
Evaluation of blood pressure changes using vascular transit time
Foo, J. Y. A., Lim, C. S., & Wang, P. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/8/003 · Cited by 62
Effects of filtering on multi-site photoplethysmography pulse waveform characteristics
Allen, J., & Murray, A. (2005) · Computers in cardiology · doi:10.1109/cic.2004.1442980 · Cited by 62
RespNet: A deep learning model for extraction of respiration from photoplethysmogram
Ravichandran, V., Murugesan, B., Vaishali, B., Ram, K., Preejith, S. P., Joseph, J., & Sivaprakasam, M. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856301 · Cited by 62
Arterial-pulse oximetry loops: a new method of monitoring vascular tone.
Shelley, K. H., Murray, W. B., & Chang, D. (1997) · The Journal of Clinical Monitoring · doi:10.1023/a:1007361020825 · Cited by 61
Gibbs, P., & Asada, H. H. (2005) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2005.1470193 · Cited by 61
Kalman Filter Based Adaptive Reduction Of Motion Artifact From Photoplethysmographic Signal
Seyedtabaii, S., & Seyedtabaii, L. (2008) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.1333655 · Cited by 59
Salehizadeh, S. M. A., Dao, D. K., Chong, J. W., McManus, D. D., Darling, C. E., Mendelson, Y., & Chon, K. H. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1030-8 · Cited by 59
Estimation of Mental Distress from Photoplethysmography
Zangróniz, R., Martínez‐Rodrigo, A., López, M. T., Pastor, J. M., & Fernández‐Caballero, A. (2018) · Applied Sciences · doi:10.3390/app8010069 · Cited by 59
Hummler, H., Engelmann, A., Pohlandt, F., Högel, J., & Franz, A. R. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0254-y · Cited by 58
Using The Morphology of Photoplethysmogram Peaks to Detect Changes in Posture
Linder, S. P., Wendelken, S., Wei, E., & McGrath, S. P. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9015-2 · Cited by 58
Liu, S.-H., Li, R.-X., Wang, J.-J., Chen, W., & Su, C.-H. (2020) · Applied Sciences · doi:10.3390/app10134612 · Cited by 58
Applications of photoelectric plethysmography in peripheral vascular disease
Hertzman, A. B., & Dillon, J. B. (1940) · American Heart Journal · doi:10.1016/s0002-8703(40)90534-8 · Cited by 57
(2008) · Journal of Medical and Biological Engineering · Cited by 57
Chang, X., Li, G., Xing, G., Zhu, K., & Tu, L. (2021) · ACM Transactions on Sensor Networks · doi:10.1145/3441626 · Cited by 57
Nilsson, L. M., Johansson, A., & Kálmán, S. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348428 · Cited by 56
Cheng, P., Chen, Z., Li, Q., Gong, Q., Zhu, J., & Liang, Y. (2020) · IEEE Access · doi:10.1109/access.2020.3025374 · Cited by 56
Nilsson, L., Johansson, A., & Kalman, S. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/4/009 · Cited by 55
Photoplethysmography Analysis of Artery Properties in Patients with Cardiovascular Diseases
Rubīns, U., Grabovskis, A., Grūbe, J., & Kukulis, I. (2008) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-69367-3_85 · Cited by 55
Nitzan, M., Faib, I., & Friedman, H. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2236285 · Cited by 55
Cuffless and Continuous Blood Pressure Estimation From PPG Signals Using Recurrent Neural Networks
El-Hajj, C., & Kyriacou, P. A. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175699 · Cited by 54
Taniguchi, H., Takata, T., Takechi, M., Furukawa, A., Iwasawa, J., Kawamura, A., Taniguchi, T., & Tamura, Y. (2021) · International Heart Journal · doi:10.1536/ihj.21-094 · Cited by 54
The effect of applied sensor contact force on pulse transit time
Teng, X. F., & Zhang, Y. T. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/8/002 · Cited by 53
Clinical usefulness of the second derivative of a plethysmogram (acceleration plethysmogram)
Takazawa, K. (1993) · Journal of Cardiology · Cited by 53
Evaluation of the signal quality of wrist-based photoplethysmography
Pradhan, N., Rajan, S., & Adler, A. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab225a · Cited by 50
Poincaré's section analysis for PPG-based automatic emotion recognition
Goshvarpour, A., & Goshvarpour, A. (2018) · Chaos Solitons & Fractals · doi:10.1016/j.chaos.2018.07.035 · Cited by 50
Sañudo, B., De Hoyo, M., Muñoz-López, A., Perry, J., & Abt, G. (2019) · Journal of Medical Systems · doi:10.1007/s10916-019-1325-2 · Cited by 48 · cited 1×
“It is known through several studies that the signal-to-noise ratio of PPG measured according to skin color or pigmentation shows a significant difference (Fallow et al., 2013; Yan et al., 2017; Sañudo et al., 2019).”
BackgroundHilmisson, H., Berman, S., & Magnúsdóttir, S. (2020) · Sleep And Breathing · doi:10.1007/s11325-020-02049-6 · Cited by 47
A Blood Pressure Monitoring Method for Stroke Management
Ma, H. T. (2014) · BioMed Research International · doi:10.1155/2014/571623 · Cited by 46
Ratiometric Artifact Reduction in Low Power Reflective Photoplethysmography
Patterson, J. A. C., & Yang, G. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2161304 · Cited by 46
Shafique, M., Kyriacou, P. A., & Pal, S. K. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0910-z · Cited by 44
Guo, Z., Ding, C., Hu, X., & Rudin, C. D. (2021) · Physiological Measurement · doi:10.1088/1361-6579/ac3b3d · Cited by 44
Relation between aortic dicrotic notch pressure and mean aortic pressure in adults
Hébert, J., Lecarpentier, Y., Zamani, K., Coirault, C., Daccache, G., Chemla, D., Wuilliez, N., & Larsonneur, L. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80086-1 · Cited by 41
Liu, J., Zhang, Y., Ding, X., Dai, W., & Zhao, N. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7590777 · Cited by 41
The effect of local mild cold exposure on pulse transit time
Zhang, X.-Y., & Zhang, Y.-T. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/7/008 · Cited by 40
Yan, L., Hu, S., Alzahrani, A., Alharbi, S., & Blanos, P. (2017) · Biosensors · doi:10.3390/bios7020022 · Cited by 40
Explainable artificial intelligence for heart rate variability in ECG signal
Sanjana, K., Sowmya, V., Gopalakrishnan, E. A., & Soman, K. P. (2020) · Healthcare Technology Letters · doi:10.1049/htl.2020.0033 · Cited by 40
Versuch die Absorptions‐Verhältnisse des Cordierites für rothes Licht zu bestimmen
Beer (1851) · Annalen der Physik · doi:10.1002/andp.18511600904 · Cited by 39
Pulse oximeter as a sensor of fluid responsiveness: do we have our finger on the best solution?
Monnet, X., Lamia, B., & Teboul, J. (2005) · Critical Care · doi:10.1186/cc3876 · Cited by 38
Ushiroyama, T., Kajimoto, Y., Sakuma, K., & Ueki, M. (2005) · Institutional Repositories DataBase (IRDB) · doi:10.57371/00000405 · Cited by 37
Tang, S. K. D., Goh, Y. Y. S., Wong, M. L. D., & Lew, Y. L. (2016) · International Conference on Intelligent and Advanced Systems · doi:10.1109/icias.2016.7824118 · Cited by 37
Tarvirdizadeh, B., Golgouneh, A., Tajdari, F., & Khodabakhshi, E. (2018) · Neural Computing and Applications · doi:10.1007/s00521-018-3767-8 · Cited by 37
Deep Learning Fused Wearable Pressure and PPG Data for Accurate Heart Rate Monitoring
Mehrgardt, P., Khushi, M., Poon, S. K.-S., & Withana, A. I. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3123243 · Cited by 37
Reflectance Forehead Pulse Oximetry: Effects of Contact Pressure During Walking
Dresher, R. P., & Mendelson, Y. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260136 · Cited by 36
Šimek, J., Wichterle, D., Melenovský, V., Malík, J., Svacina, S., & Widimsky, J., Jr. (2005) · Physiological Research · doi:10.33549/physiolres.930683 · Cited by 36
Kim, J., Kim, J.-H., & Ko, H. (2015) · Sensors · doi:10.3390/s16010046 · Cited by 36
Postoperative Pain Assessment Indices Based on Photoplethysmography Waveform Analysis
Yang, Y. L., Seok, H. S., Noh, G., Choi, B., & Shin, H. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01199 · Cited by 36
Self-citationReliable PPG-based algorithm in atrial fibrillation detection
Shan, S.-M., Tang, S., Huang, P.-W., Lin, Y., Huang, W.-H., Lai, D., & Wu, A.-Y. A. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833801 · Cited by 35
Liu, S.-H., Wang, J.-J., Chen, W., Pan, K., & Su, C.-H. (2020) · Applied Sciences · doi:10.3390/app10041476 · Cited by 35
Lee, Q. Y., Redmond, S. J., Chan, G. S., Middleton, P. M., Steel, E., Malouf, P., Critoph, C., Flynn, G., O’Lone, E., & Lovell, N. H. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-19 · Cited by 34
Relations between ac-dc components and optical path length in photoplethysmography
Lee, C., Shin, H., & Lee, M. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3600769 · Cited by 34
Self-citationWang, L., Poon, C. C. Y., & Zhang, Y. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/5/008 · Cited by 33
Papini, G. B., Fonseca, P. M., Eerikäinen, L. M., Overeem, S., Bergmans, J. W. M., & Vullings, R. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aae7f8 · Cited by 33
McKay, N. D., Griffiths, B., Maria, C. D., Hedley, S., Murray, A., & Allen, J. (2014) · Lara D. Veeken · doi:10.1093/rheumatology/keu196 · Cited by 32
Left ventricular end-systolic pressure estimated from measurements in a peripheral artery
Dahlgren, G., Veintemilla, F., Settergren, G., & Liška, J. (1991) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/1053-0770(91)90004-d · Cited by 32
Automated detection of the onset and systolic peak in the pulse wave using Hilbert transform
Ferro, B. T. R., Aguilera, A. R., & Prieto, R. R. F. D. L. V. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.04.009 · Cited by 31
Analysing the effects of cold, normal, and warm digits on transmittance pulse oximetry
Khan, M., Pretty, C. G., Amies, A. C., Elliott, R. B., Chiew, Y. S., Shaw, G. M., & Chase, J. G. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.12.006 · Cited by 31
Supraorbital photoplethysmography. Simple, accurate screening for carotid occlusive disease
Barnes, R. W., Clayton, J. M., Bone, G. E., Slaymaker, E. E., & Reinertson, J. E. (1977) · Journal of Surgical Research · doi:10.1016/0022-4804(77)90150-0 · Cited by 30
Shin, H., Lee, C., & Lee, M. (2009) · Journal of Medical Systems · doi:10.1007/s10916-009-9289-2 · Cited by 29
Self-citationComparison and Noise Suppression of the Transmitted and Reflected Photoplethysmography Signals
Li, S., Liu, L., Wu, J., Tang, B., & Li, D. (2018) · BioMed Research International · doi:10.1155/2018/4523593 · Cited by 29
Postoperative Pain Assessment Model Based on Pulse Contour Characteristics Analysis
Seok, H. S., Choi, B., Noh, G., & Shin, H. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2890482 · Cited by 29
Self-citationGoshvarpour, A., & Goshvarpour, A. (2020) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-020-00526-7 · Cited by 29
Matsumura, K., Toda, S., & Kato, Y. (2020) · IEEE Access · doi:10.1109/access.2020.2990438 · Cited by 28
A contact-force regulated photoplethysmography (PPG) platform
Sim, J. K., Ahn, B., & Doh, I. (2018) · AIP Advances · doi:10.1063/1.5020914 · Cited by 27
Insight into the dicrotic notch in photoplethysmographic pulses from the finger tip of young adults
Shi, P. A., Hu, S., Zhu, Y. J., Zheng, J., Qiu, Y., & Cheang, P.-Y. (2009) · Journal of Medical Engineering & Technology · doi:10.3109/03091900903150980 · Cited by 27
Cited by
A PPG Signal Dataset Collected in Semi-Naturalistic Settings Using Galaxy Watch
Park, S., Zheng, D., & Lee, U. (2025) · Scientific Data · doi:10.1038/s41597-025-05152-z · Cited by 12
Metadata
- Authors
- Park, J., Seok, H. S., Kim, S.-S., & Shin, H.
- Venue
- Frontiers in Physiology
- Publisher
- Frontiers Media SA
- Published
- 2022-03-01
- Volume
- 12
- Pages
- 808451-808451
- ISSN
- 1664-042X (ISSN-L)
- OpenAlex
- W4214602270
- Cited by
- 422
- References
- 229
- FWCI
- 21.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.