Carbon nanotube electrodes for effective interfacing with retinal tissue
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We have investigated the use of carbon nanotube coated microelectrodes as an interface material for retinal recording and stimulation applications. Test devices were micro-fabricated and consisted of 60, 30 mum diameter electrodes at spacing of 200 mum. These electrodes were coated via chemical vapor deposition of carbon nanotubes, resulting in conducting, three dimensional surfaces with a high interfacial area. These attributes are important both for the quality of the cell-surface coupling as well as for electro-chemical interfacing efficiency. The entire chip was packaged to fit a commercial multielectrode recording and stimulation system. Electrical recordings of spontaneous spikes from whole-mount neonatal mouse retinas were consistently obtained minutes after retinas were placed over the electrodes, exhibiting typical bursting and propagating waves. Most importantly, the signals obtained with carbon nanotube electrodes have exceptionally high signal to noise ratio, reaching values as high as 75. Moreover, spikes are marked by a conspicuous gradual increase in amplitude recorded over a period of minutes to hours, suggesting improvement in cell-electrode coupling. This phenomenon is not observed in conventional commercial electrodes. Electrical stimulation using carbon nanotube electrodes was also achieved. We attribute the superior performances of the carbon nanotube electrodes to their three dimensional nature and the strong neuro-carbon nanotube affinity. The results presented here show the great potential of carbon nanotube electrodes for retinal interfacing applications. Specifically, our results demonstrate a route to achieve a reduction of the electrode down to few micrometers in order to achieve high efficacy local stimulation needed in retinal prosthetic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Leber congenital amaurosis: Genes, proteins and disease mechanisms
den Hollander, A. I., Roepman, R., Koenekoop, R. K., & Cremers, F. P. M. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2008.05.003 · Cited by 811 · cited 1×
“Vision loss due to retinal degeneration (e.g. Leber Congenital Amaurosis; den Hollander et al., 2008 or age-related macular degeneration; Ehrlich et al., 2008) is a worldwide impairment in ageing populations, often leading to complete blindness.”
Carbon Nanotube Substrates Boost Neuronal Electrical Signaling
Lovat, V., Pantarotto, D., Lagostena, L., Cacciari, B., Grandolfo, M., Righi, M., Spalluto, G., Prato, M., & Ballerini, L. (2005) · Nano Letters · doi:10.1021/nl050637m · Cited by 648 · cited 1×
“A recent investigation has demonstrated qualitative differences between the activity of neurons cultured on CNTs and on smooth surfaces (Lovat et al., 2005).”
Cited by
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Organic electrode coatings for next-generation neural interfaces
Aregueta-Robles, U. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 254
Biomaterials‐Based Electronics: Polymers and Interfaces for Biology and Medicine
Muskovich, M., & Bettinger, C. J. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200071 · Cited by 182
Carbon nanotubes in neuroregeneration and repair
Fabbro, A., Prato, M., & Ballerini, L. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.002 · Cited by 174
“Currently, carbon nanotube-based applications in neuroscience include: electrical interfaces for neuronal stimulation and recording (that drastically improve the electrode performance, both in vitro and in vivo [5,29,30,37,38]) as well as platforms to promote neuronal survival, differentiation, growth and performance…”
BackgroundCellot, G., Toma, F. M., Kasap Varley, Z., Laishram, J., Villari, A., Quintana, M., Cipollone, S., Prato, M., & Ballerini, L. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.1332-11.2011 · Cited by 158
Metadata
- Authors
- Shoval, A.
- Venue
- Frontiers in Neuroengineering
- Publisher
- Frontiers Media SA
- Published
- 2009
- Volume
- 2
- Pages
- 4-4
- ISSN
- 1662-6443 (ISSN-L)
- OpenAlex
- W2071581239
- Cited by
- 96
- References
- 2
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carbon nanotube electrodes for effective interfacing with retinal tissue. https://app.cochat.ai/papers/10.3389/neuro.16.004.2009
- The paper
- Shoval, A. (2009). Carbon nanotube electrodes for effective interfacing with retinal tissue. Frontiers in Neuroengineering. https://doi.org/10.3389/neuro.16.004.2009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.