CoChat

Optimal Design of High-Power Density Medium-Voltage Direct Current Bipolar Power Cables for Lunar Power Transmission

Open access
Saha, Anoy, Ghassemi, Mona · 2024 · Aerospace

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index; none of the 20 sources its claims cite is checked for support yet.

Abstract

This study presents a novel approach for designing bipolar MVDC cables for lunar subsurface power transmission.

Overview

CoChat Summary

TL;DR

This study designs and analyzes coaxial bipolar MVDC cables for lunar subsurface power transmission using a COMSOL coupled electrothermal model, with Kapton® MT+ insulation and aluminum or copper conductors at ±5/±10 kV and 200 kW/1 MW/2 MW. It finds aluminum generally lowers weight at medium/high power, higher voltage ±10 kV improves design efficiency, and the designed cable is lighter and smaller than a Southwire 5 kV NL-EPR benchmark.

Key findings

  • Aluminum conductors consistently show lower weight per unit length than copper at medium and high power. For 200 kW at ±10 kV, Al weighs 0.0608 kg/m, about 12% less than Cu; at 1 MW, Al is 0.3567 kg/m, about 39.41% lower than Cu; at 2 MW, Al is 1.0092 kg/m, about 82% lower than Cu’s 1.8383 kg/m.
  • Higher voltage reduces weight: switching Al from ±10 kV to ±5 kV raises weight to 0.0879 kg/m at 200 kW (reported as ~44.57% increase), 0.9602 kg/m at 1 MW (~169% higher), and 2.8991 kg/m at 2 MW (~187% higher).
  • Copper needs smaller cross-sectional area, while aluminum often gives lower combined weight-area parameter J. For 200 kW, Cu at ±10 kV has the smallest area, 22.602 mm² (~13.6% smaller than Al) and the lowest J, 1.5617 g.mm (~1.81% lower than Al). For 1 MW and 2 MW, Al at ±10 kV has the lowest J, 50.266 g.mm (~12.5% lower than Cu) and 392.69 g·mm (~17.6% lower than Cu), respectively.
  • For 2 MW at ±5 kV, the designed coaxial cable weighs 5.7802 kg/m versus 7.7157 kg/m for the NL-EPR cable (~25% lower) and has 693.81 mm² area versus 1748.6 mm² (~60% lower). Maximum electric field is 2.24 × 10⁷ V/m, meeting the E_max < 0.2E_bd criterion, and cable surface temperature stabilizes around 260 °C.

Methods

  • A coupled electrothermal model was built in COMSOL Multiphysics 6.1 using heat transfer, electric current, and magnetic field modules. The cable is placed 30 cm below the lunar surface; only conductive heat transfer is modeled. Surface temperature is held at 110.85 °C for 327.6 h and −171.1 °C for 327.6 h, with a 2000 h simulation; soil thermal conductivity is constant at 1.0 × 10⁻⁴ W/(cm·K). Mesh used 19,866 vertices and 39,474 triangular elements.
  • The design is a coaxial bipolar MVDC cable using Kapton® MT+ insulation, a Teflon® PFA jacket, and a copper EMI screen, with Al or Cu core conductors. Kapton® MT+ is selected for its −269 to 400 °C range, 0.75 W/m·K thermal conductivity, and dielectric constant 4.2, compared with XLPE (0.46 W/m·K, 2.5) and NL-EPR (0.3 W/m·K, 2.5).
  • Optimization determines insulation number, type, and thickness to minimize weight and volume while meeting electrical and thermal limits: E_max < 0.2E_bd and T_max < T_limit. The study covers 12 cases: 200 kW, 1 MW, and 2 MW at ±5 kV and ±10 kV, with Al or Cu. Results compare weight per unit length, cross-sectional area, and J = m·A, and benchmark against a Southwire 5 kV NL-EPR cable for 2 MW.

Limitations

  • Stated: the simulation accounts only for conductive heat transfer, ignores pressure fluctuations, assumes micrometeoroid bombardment is less impactful at 30 cm depth, and assumes 30 cm depth protects against solar wind and SEPs while noting GCRs could still impact the cable. The specific impact of charged particles remains uncertain, and the insulation design does not address deep dielectric charging.
  • Stated: cable lifespan was not directly assessed; the simulation ran for 2000 h, and without experimental testing the precise lifespan remains uncertain, requiring ongoing monitoring and further assessment.
  • Evident from the text: no experimental validation is reported, and Kapton® MT+ and Teflon® PFA conductivities were approximated as polyimide (PI) and ethylene-tetrafluoroethylene (ETFE), respectively, due to lack of specific data. Some numerical statements in the provided text also appear duplicated or inconsistently worded, such as the 44.57% comparison.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/aerospace11080685

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 2 Not valid · 17 Not checked · 48 Own results and interpretations

29 more claims

Create a free account to see all 67 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 25
  • The quote only partly states this claim. 2
  • Probably not a substantial claim. 8

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Show all 22 references

Research works printed but not linked: 5

  1. 5. IEC 60287-1-1:2006; Electric Cables-Calculation of the Current Rating-Part 1-1: Current Rating Equations (100% Load Factor) and Calculation of Losses-General. IEC: Geneva, Switzerland, 2006; pp. 1-136.
  2. 7. IEC 60986:2000; Short-Circuit Temperature Limits of Electric Cables with Rated Voltages from 6 kV (Um = 7.2 kV) up to 30 kV (Um = 36 kV). IEC: Geneva, Switzerland, 2000; pp. 1-19.
  3. 8. IEC TR 62095:2003; Electric Cables-Calculations for Current Ratings-Finite Element Method. IEC: Geneva, Switzerland, 2003; pp. 1-69.
  4. 9. Smith, R.E.; West, G.S. Space and Planetary Environment Criteria Guidelines for Use in Space Vehicle Development. Volume 1: 1982 Revision; 1983; Volume 83, p. 18816. Available online: https://ntrs.nasa.gov/api/citations/19830019790/downloads/1983001979 0.pdf (accessed on 13 April 2024).
  5. 22. Heiken, G.; Vaniman, D.; French, B.M. Lunar Sourcebook; Cambridge University Press: New York, NY USA, 1991.

Cited by

See all 8

Metadata

Authors
Saha, A., & Ghassemi, M.
Affiliations
The University of Texas at Dallas (US)
Corresponding author
Ghassemi, Mona
Venue
Aerospace
Publisher
MDPI AG
Published
2024-08-20
Volume
11
Issue
8
Pages
685
ISSN
2226-4310 (ISSN-L)
OpenAlex
W4401976955
Cited by
8
References
22
Citations by year
2026: 3 · 2025: 2 · 2024: 3
FWCI
0.78
Type
journal article
Language
en
Open access
Locations
  • Aerospace (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › High voltage insulation and dielectric phenomena
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Thermal Analysis in Power Transmission
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
Keywords
aluminum conductors, copper conductors, lunar temperature, ionizing radiation, micrometeoroid impacts, power transfer efficiency

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimal Design of High-Power Density Medium-Voltage Direct Current Bipolar Power Cables for Lunar Power Transmission. https://app.cochat.ai/papers/10.3390/aerospace11080685
The paper
Saha, A., & Ghassemi, M. (2024). Optimal Design of High-Power Density Medium-Voltage Direct Current Bipolar Power Cables for Lunar Power Transmission. Aerospace. https://doi.org/10.3390/aerospace11080685

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.