CoChat

A Novel Wearable Foot and Ankle Monitoring System for the Assessment of Gait Biomechanics

Open access

The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.

Abstract

Walking is the most basic form of human activity for achieving mobility. As an essential function of the human body, the examination of walking is directed towards the assessment of body mechanics in posture and during movement. This work proposes a wearable smart system for the monitoring and objective evaluation of foot biomechanics during gait. The proposed solution assumes the cross-correlation of the plantar pressure with lower-limb muscular activity, throughout the stance phase of walking. Plantar pressure is acquired with an array of resistive pressure sensors deployed onto a shoe insole along the center of gravity progression line. Lower-limb muscular activity is determined from the electromyogram of the tibialis anterior and gastrocnemius lower limb muscles respectively. Under this scenario, physiological gait assumes the interdependency of plantar pressure on the heel area with activation of the tibialis anterior, as well as plantar pressure on the metatarsal arch/toe area with activation of the gastrocnemius. As such, assessment of gait physiology is performed by comparison of a gait map, formulated based on the footprint–lower-limb muscle cross-correlation results, to a reference gait template. A laboratory proof of concept validates the proposed solution in a test scenario which assumes a normal walking and two pathological walking patterns.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/app11010268

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Representation of the footprint division into three regions: forefoot, midfoot and heel, with the illustration of the ten anatomical areas accountant for the derivation of lower-limb and whole-body physiological, structural and functional information. Figure 1. Representation of the footprint division into three regions: forefoot, midfoot and heel, with the illustration of the ten anatomical areas accountant for the derivation of lower-limb and whole-body physiological, structural and functional information.
Figure 1 Representation of the footprint division into three regions: forefoot, midfoot and heel, with the illustration of the ten anatomical areas accountant for the derivation of lower-limb and whole-body physiological, structural and functional information. Figure 1. Representation of the footprint division into three regions: forefoot, midfoot and heel, with the illustration of the ten anatomical areas accountant for the derivation of lower-limb and whole-body physiological, structural and functional information.CC-BY · From the PDF
Image 2
CC-BY · From the PDF
Image 3
CC-BY · From the PDF
Figure 4 Center of pressure progression line for ( a ) physiological gait, ( b ) abnormal gait. Figure 4. Center of pressure progression line for ( a ) physiological gait, ( b ) abnormal gait.
Figure 4 Center of pressure progression line for ( a ) physiological gait, ( b ) abnormal gait. Figure 4. Center of pressure progression line for ( a ) physiological gait, ( b ) abnormal gait.CC-BY · From the PDF
Figure 5 Solutions of pressure sensor deployment on the footprint for dynamic assessment: ( a ) assessment of the footprint medial line with sensors deployed onto the hallux, metatarsal arch, lateral arch and heel respectively [13], ( b ) additional sensor deployed on the medial arch for flatfoot identification [14], ( c ) additional sensor deployed on the lesser toes and medial arch for flatfoot identification [15], ( d ) additional sensor deployed on the lesser toes [16]. Figure 5. Solutions of pressure sensor deployment on the footprint for dynamic assessment: ( a ) assessment of the footprint medial line with sensors deployed onto the hallux, metatarsal arch, lateral arch and heel respectively [13], ( b ) additional sensor deployed on the medial arch for flatfoot identification [14], ( c ) additional sensor deployed on the lesser toes and medial arch for flatfoot identification [15], ( d ) additional sensor deployed on the lesser toes [16].
Figure 5 Solutions of pressure sensor deployment on the footprint for dynamic assessment: ( a ) assessment of the footprint medial line with sensors deployed onto the hallux, metatarsal arch, lateral arch and heel respectively [13], ( b ) additional sensor deployed on the medial arch for flatfoot identification [14], ( c ) additional sensor deployed on the lesser toes and medial arch for flatfoot identification [15], ( d ) additional sensor deployed on the lesser toes [16]. Figure 5. Solutions of pressure sensor deployment on the footprint for dynamic assessment: ( a ) assessment of the footprint medial line with sensors deployed onto the hallux, metatarsal arch, lateral arch and heel respectively [13], ( b ) additional sensor deployed on the medial arch for flatfoot identification [14], ( c ) additional sensor deployed on the lesser toes and medial arch for flatfoot identification [15], ( d ) additional sensor deployed on the lesser toes [16].CC-BY · From the PDF
Image 6
CC-BY · From the PDF
Figure 7 The wearable foot biomechanics monitoring system laboratory proof of concept: ( a ) circuit setup, ( b ) system wearing on the lower limb. Figure 7. The wearable foot biomechanics monitoring system laboratory proof of concept: ( a ) circuit setup, ( b ) system wearing on the lower limb.
Figure 7 The wearable foot biomechanics monitoring system laboratory proof of concept: ( a ) circuit setup, ( b ) system wearing on the lower limb. Figure 7. The wearable foot biomechanics monitoring system laboratory proof of concept: ( a ) circuit setup, ( b ) system wearing on the lower limb.CC-BY · From the PDF
Figure 8 Logical diagram of the wearable foot biomechanics monitoring system software. Figure 8. Logical diagram of the wearable foot biomechanics monitoring system software.
Figure 8 Logical diagram of the wearable foot biomechanics monitoring system software. Figure 8. Logical diagram of the wearable foot biomechanics monitoring system software.CC-BY · From the PDF
Figure 9 Proposed pressure sensor deployment along the COP progression line for plantar pressure assessment: ( a ) diagram, ( b ) practical realization. Figure 9. Proposed pressure sensor deployment along the COP progression line for plantar pressure assessment: ( a ) diagram, ( b ) practical realization.
Figure 9 Proposed pressure sensor deployment along the COP progression line for plantar pressure assessment: ( a ) diagram, ( b ) practical realization. Figure 9. Proposed pressure sensor deployment along the COP progression line for plantar pressure assessment: ( a ) diagram, ( b ) practical realization.CC-BY · From the PDF
Figure 10 Electrode placement for lower-limb EMG acquisition of the ( a ) tibialis anterior, ( b ) Figure 10. Electrode placement for lower-limb EMG acquisition of the ( a ) tibialis anterior, ( b ) gastrocnemius.
Figure 10 Electrode placement for lower-limb EMG acquisition of the ( a ) tibialis anterior, ( b ) Figure 10. Electrode placement for lower-limb EMG acquisition of the ( a ) tibialis anterior, ( b ) gastrocnemius.CC-BY · From the PDF
Figure 11 Block diagram of the EMG feature extraction procedure assuming two parallel lowpass filters: 50 Hz lowpass filter for muscular activity and 150 Hz for the muscle activation pattern. Figure 11. Block diagram of the EMG feature extraction procedure assuming two parallel lowpass filters: 50 Hz lowpass filter for muscular activity and 150 Hz for the muscle activation pattern.
Figure 11 Block diagram of the EMG feature extraction procedure assuming two parallel lowpass filters: 50 Hz lowpass filter for muscular activity and 150 Hz for the muscle activation pattern. Figure 11. Block diagram of the EMG feature extraction procedure assuming two parallel lowpass filters: 50 Hz lowpass filter for muscular activity and 150 Hz for the muscle activation pattern.CC-BY · From the PDF
Image 12
CC-BY · From the PDF
Image 13
CC-BY · From the PDF
Figure 14 Illustration of the FSR and EMG interdependency via the cross-correlation of the binarized FSR reading and EMG activation which exhibits a maximum in the origin: ( a ) FSR5 and tibialis anterior at heel strike, and ( b ) FSR0 and gastrocnemius at toe-off. Figure 14. Illustration of the FSR and EMG interdependency via the cross-correlation of the binarized FSR reading and EMG activation which exhibits a maximum in the origin: ( a ) FSR5 and tibialis anterior at heel strike, and ( b ) FSR0 and gastrocnemius at toe-off.
Figure 14 Illustration of the FSR and EMG interdependency via the cross-correlation of the binarized FSR reading and EMG activation which exhibits a maximum in the origin: ( a ) FSR5 and tibialis anterior at heel strike, and ( b ) FSR0 and gastrocnemius at toe-off. Figure 14. Illustration of the FSR and EMG interdependency via the cross-correlation of the binarized FSR reading and EMG activation which exhibits a maximum in the origin: ( a ) FSR5 and tibialis anterior at heel strike, and ( b ) FSR0 and gastrocnemius at toe-off.CC-BY · From the PDF
Image 15
CC-BY · From the PDF
Figure 16 Illustration of the FSR and EMG lack of interdependency via the cross-correlation of the binarized FSR reading and EMG activation which does not have a maximum in the origin: ( a ) FSR1 and tibialis anterior at heel strike, and ( b ) FSR5 and gastrocnemius at toe-off. Figure 16. Illustration of the FSR and EMG lack of interdependency via the cross-correlation of the binarized FSR reading and EMG activation which does not have a maximum in the origin: ( a ) FSR1 and tibialis anterior at heel strike, and ( b ) FSR5 and gastrocnemius at toe-off. Figure 16. Illustration of the FSR and EMG lack of interdependency via the cross-correlation of the binarized FSR reading and EMG activation which does not have a maximum in the origin: ( a ) FSR1 and tibialis anterior at heel strike, and ( b ) FSR5 and gastrocnemius at toe-off.
Figure 16 Illustration of the FSR and EMG lack of interdependency via the cross-correlation of the binarized FSR reading and EMG activation which does not have a maximum in the origin: ( a ) FSR1 and tibialis anterior at heel strike, and ( b ) FSR5 and gastrocnemius at toe-off. Figure 16. Illustration of the FSR and EMG lack of interdependency via the cross-correlation of the binarized FSR reading and EMG activation which does not have a maximum in the origin: ( a ) FSR1 and tibialis anterior at heel strike, and ( b ) FSR5 and gastrocnemius at toe-off. Figure 16. Illustration of the FSR and EMG lack of interdependency via the cross-correlation of the binarized FSR reading and EMG activation which does not have a maximum in the origin: ( a ) FSR1 and tibialis anterior at heel strike, and ( b ) FSR5 and gastrocnemius at toe-off.CC-BY · From the PDF
Image 17
CC-BY · From the PDF
Figure 17 The FSR recordings during a stance phase, following the successive activatio heel area, FSR4 to FSR1-midfoot, and FSR0-hallux. Figure 17. The FSR recordings during a stance phase, following the successive activation of FSR5heel area, FSR4 to FSR1-midfoot, and FSR0-hallux. Figure 17. The FSR recordings during a stance phase, following the successive ac heel area, FSR4 to FSR1-midfoot, and FSR0-hallux.
Figure 17 The FSR recordings during a stance phase, following the successive activatio heel area, FSR4 to FSR1-midfoot, and FSR0-hallux. Figure 17. The FSR recordings during a stance phase, following the successive activation of FSR5heel area, FSR4 to FSR1-midfoot, and FSR0-hallux. Figure 17. The FSR recordings during a stance phase, following the successive ac heel area, FSR4 to FSR1-midfoot, and FSR0-hallux.CC-BY · From the PDF
Image 19
CC-BY · From the PDF
Image 20
CC-BY · From the PDF
Figure 21 Cross-correlation of the FSRs to the ( a ) tibialis anterior and the ( b ) gastrocnemius. Figure 21. Cross-correlation of the FSRs to the ( a ) tibialis anterior and the ( b ) gastrocnemius.
Figure 21 Cross-correlation of the FSRs to the ( a ) tibialis anterior and the ( b ) gastrocnemius. Figure 21. Cross-correlation of the FSRs to the ( a ) tibialis anterior and the ( b ) gastrocnemius.CC-BY · From the PDF
Figure 22 The FSR recordings during a stance phase, plotted alongside the tibialis anterior and gastrocnemius EMG respectively. Figure 22. The FSR recordings during a stance phase, plotted alongside the tibialis anterior and gastrocnemius EMG respectively.
Figure 22 The FSR recordings during a stance phase, plotted alongside the tibialis anterior and gastrocnemius EMG respectively. Figure 22. The FSR recordings during a stance phase, plotted alongside the tibialis anterior and gastrocnemius EMG respectively.CC-BY · From the PDF
Figure 23 Surface plot of the bi-dimensional cross-correlation of the gait map Figure 23. Surface plot of the bi-dimensional cross-correlation of the gait map from Table 5 to the physiological gait map template from Table 4.
Figure 23 Surface plot of the bi-dimensional cross-correlation of the gait map Figure 23. Surface plot of the bi-dimensional cross-correlation of the gait map from Table 5 to the physiological gait map template from Table 4.CC-BY · From the PDF
Image 24
CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 47 references

Research works printed but not linked: 7

  1. 2. Kendal, F.P.; Kendal McCreary, E.; Provance, P.G.; Rodgers, M.M.; Romani, W.A. Muscles: Testing and Testing and Function with Posture and Pain , 5th ed.; Lippincott Williams & Wilkins: Baltimore, MD, USA, 2005.
  2. 7. Wei, Q.; Lu, W.; Fu, Z.; Lu, S. A new system for foot pressure measurement and gait analysis. Chin. J. Biomed. Eng. 2000 , 19 , 32-40.
  3. 8. Maier, L. Portable Plantar Pressure Monitoring System Implemented with Arduino UNO (Original in Romanian: Sistem Portabil de Monitorizare a Presiunii Plantare Implementat cu Arduino UNO). Diploma Thesis, Technical University of Cluj-Napoca, Cluj-Napoca, Romania, 2019.
  4. 12. Bonnefoy, A.; Armand, S. Normal Gait. In Orthopedic Management of Children with Cerebral Palsy: A Comprehensive Approach ; Canavesse, F., Deslandes, J., Eds.; Nova Science Publishers: Hauppauge, NY, USA, 2015; pp. 199-213. ISBN 978-1-63483-318-9.
  5. 18. Qaqish, J.; McLean, S. Foot Type and Tibialis Anterior Muscle Activity during Stance Phase of Gait. Int. J. Physiother. Rehabil. 2010 , 1 , 19-29.
  6. 39. Prasad, N.K.; Coleman Wood, K.A.; Spinner, R.J.; Kaufman, K.R. Foot and Ankle Kinematics and Dynamic Electromyography: Quantitative Analysis of Recovery from Peroneal Neuropathy in a Professional Football Player. J. Surg. Orthop. Adv. 2016 , 25 , 180-186.
  7. 41. Narwaria, R.P.; Verma, S.; Singhal, P.K. Removal of Baseline Wander and Power Line Interference from ECG Signal-A Survey Approach. Int. J. Electron. Eng. 2011 , 3 , 107-111.

Cited by

See all 25

Metadata

Authors
Faragó, P., Grama, L., Farago, M.-A., & Hintea, S.
Affiliations
  • Technical University of Cluj-Napoca (RO)
  • University of Oradea (RO)
Corresponding author
Faragó, Paul
Venue
Applied Sciences
Publisher
MDPI AG
Published
2020-12-29
Volume
11
Issue
1
Pages
268
ISSN
2076-3417 (ISSN-L)
OpenAlex
W3114637180
Cited by
22
References
47
Citations by year
2026: 3 · 2025: 2 · 2024: 6 · 2023: 3 · 2022: 4 · 2021: 4
FWCI
0.87
Type
journal article
Language
en
Open access
Locations
  • Applied Sciences (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
  • Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
Keywords
wearable gait monitoring, foot biomechanics, plantar pressure, electromyography, tibialis anterior, gastrocnemius, cross correlation function, resistive pressure sensors, insole sensors, gait analysis, pathological gait

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.