Bacteria Filtration Efficiency for Different Types of Protective Face Masks
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index; 10 of the 29 sources its claims cite were checked for support.
Abstract
Emerging infectious diseases that we are witnessing in the modern age are among the leading public health concerns. They most often occur in the form of epidemics or pandemics, and they have not been sufficiently researched. Owing to the current coronavirus disease 2019 (COVID-19) pandemic, the World Health Organization has published various recommendations to prevent the spread of this communicable disease, including a recommendation to wear protective facial masks. Therefore, this study aimed to determine the filtration effectiveness of bacteria, yeasts, and molds on three different commonly and commercially available masks used in children’s educational institutions. In addition, the bacterial content of indoor air bioaerosols was identified. The genera Staphylococcus and Micrococcus were dominant in all samples, whereas bacteria of the genera Bacillus, Acinetobacter, and Corynebacterium were identified at a significantly smaller number. Bacterial, yeast, and mold filtering effectiveness increased from the single-layer cloth mask, which proved to be the least effective, to the surgical mask, to the filtering facepiece type 2 (FFP2) mask. Furthermore, surveys are needed to study the effectiveness of protective measures.
Overview
CoChat Summary
TL;DR
This study assessed bacterial, yeast, and mold filtration efficiency of single-layer cloth, surgical, and FFP2 masks during air sampling in two kindergarten and two primary school groups. Filtration effectiveness increased from single-layer cloth (least effective) to surgical to FFP2.
Key findings
- For total aerobic mesophilic bacteria, single-layer cloth masks retained 28–78% (highest at location B, 78%), surgical masks 93–98%, and FFP2 masks 98–100%; all mask treatments differed significantly from control (p < 0.01).
- For yeasts and molds, FFP2 masks achieved 94–100% filtration and single-layer cloth masks 13–79%; all mask treatments were significantly different from control (p < 0.01). At location A, surgical and FFP2 did not differ (100% both); at location B, cloth and surgical did not differ (79%). The text also states no yeast or mold colonies were recorded after FFP2 filtration.
- Staphylococcus and Micrococcus were dominant in all samples; M. luteus was most prevalent at all locations, followed by A. lwoffi and S. haemolyticus. M. luteus accounted for 40% of total identified bacteria at locations A and C and an average of 88% at locations B and D; A. lwoffi and S. haemolyticus were higher at A/C (19% and 20% on average) than at B/D (6% and 3%).
- PCA on 396 pooled data sets showed three components explaining 91.94% of variance (p1 60.79%, p2 19.33%, p3 11.83%); FFP2 and surgical masks (except surgical at location D) were effective, while single-layer cloth masks were weak or ineffective.
Methods
- Air samples were collected from four child groups: kindergarten A and B and primary school C and D, with a no-mask control at each location; sampling used a MAS-100 NT sampler, 250 L air at 0.45 m/s. Locations had 33–38% humidity, 21.0–23.3 °C, 10–23 persons, and 49–60 m² room area.
- Masks tested were single-layer cotton cloth, classic surgical, and FFP2 NR. Microbial counts used tryptic soy agar, blood agar, chromogenic Brilliance UTI agar, and Sabouraud dextrose agar; identification included colony morphology, catalase/coagulase/oxidase tests, and API 20STAPH.
- Data are means of three measurements ± SD; differences were tested with nonparametric Kruskal-Wallis multiple comparisons at p < 0.01, normalized to control, and analyzed with PCA.
Limitations
- The paper states that mask fit/gaps affect efficiency, that the air sampler may have influenced results, that yeast and mold species were not further identified, and that further study of protective measures is needed.
- The authors also state that prior ventilation, children's activity, age, and health condition of individuals present may have caused filtration differences.
- Evident from the text: only four child groups and one mask per type were tested, with no reported control for ventilation, activity, occupancy, or fit/leakage.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



![Figure 2 Number of grown colonies of ( a ) aerobic mesophilic bacteria on tryptic soy agar (TSA) and ( b ) yeasts and molds on Sabouraud agar (SA) from four locations (A, B, C, D) in the control group after air filtration with cloth, surgical, and filtering facepiece type 2 (FFP2) masks expressed as colony forming unit (CFU)/250 L of air. The data are presented as mean values of three determinations with standard deviations. Mean values marked with capital letter A represent significant differences between the control group and each treatment with cloth, surgical, and FFP2 masks, while lowercase letters a and b represent significant differences within treatments ( p < 0.01; nonparametric KruskalWallis [multiple comparisons] test). Figure 2. Number of grown colonies of ( a ) aerobic mesophilic bacteria on tryptic soy agar (TSA) and ( b ) yeasts and molds on Sabouraud agar (SA) from four locations (A, B, C, D) in the control group after air filtration with cloth, surgical, and filtering facepiece type 2 (FFP2) masks expressed as colony forming unit (CFU)/250 L of air. The data are presented as mean values of three determinations with standard deviations. Mean values marked with capital letter A represent significant differences between the control group and each treatment with cloth, surgical, and FFP2 masks, while lowercase letters a and b represent significant differences within treatments ( p < 0.01; nonparametric Kruskal-Wallis [multiple comparisons] test).](https://figures.cochat.ai/paper-figures/f85b4476a32848d1871ea2e216fd7558/bacteria-filtration-efficiency-for-different-types-of-protective-face-masks-figure-2.png)





Verification
Claims the paper makes
10 Valid · 1 Not valid · 12 Not checked · 81 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“It has been reported that the use of singlelayer cloth masks can result in significantly higher rates of infection than can the use of surgical masks, with this information being obtained from a randomized trial in healthcare workers [20,21].”
What the sources say
- Partly supportedcites [20] MacIntyre, 2015, Randomised trial of cloth masks compared with medical masks in healthcare workers, Open BMJ Publ. Group sourceExperimental — accuracy not yet measured
The Abstract Results and Discussion report significantly higher infection outcomes for healthcare workers assigned cloth masks than for those assigned medical masks in this randomised trial. However, Methods > Intervention specifies that the cloth masks had two layers of cotton, not a single layer. The trial also could not determine whether the difference reflected a detrimental effect of cloth masks, a protective effect of medical masks, or both. (LLM, conf=0.90)
- Not checked — no full text of the sourcecites [21] Yang, 2011, Mask-wearing and respiratory infection in healthcare workers in Beijing, China, Braz. J. Infect. Dis. source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The effect of gaps between the face and the mask as caused by an improper fit will affect the efficiency of any face mask for any microorganism.”
- Also stated in: § References · p. 15 · plain
“the importance of the fit while using the face mask will affect the efficiency of any face mask.”
What the sources say
- Partly supportedcites [15] Rengasamy, 2012, Nanoparticle penetration through filter media and leakage through face seal interface of N95 filtering face piece respirators, Ann. Occup. Hyg. sourceExperimental — accuracy not yet measured
The Introduction and Discussion (page unavailable) say that face-seal leakage reduces respiratory protection and that better-fitting respirators protect better against nanoparticles. The paper studies N95 respirators and particle leakage; it does not establish the claim for every face mask or every microorganism. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § References · p. 15 · plain
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“wearing surgical or FFP2 masks substantially reduces the number of bioaerosol particles emitted from human respiration.”
What the sources say
- Partly supportedcites [25] Asadi, 2020, Efficacy of masks and face coverings in controlling outward aerosol particle emission from expiratory activities, Sci. Rep. sourceExperimental — accuracy not yet measured
The Results report substantially fewer particles emitted during breathing with surgical masks and KN95 respirators, and the Conclusions extend that finding to talking and coughing. The Methods list the respirators tested as KN95 and N95, not FFP2, so the FFP2-specific part of the claim is not directly supported. (LLM, conf=0.88)
- Not checked — no full text of the sourcecites [26] Qian, 1998, Performance of N95 respirators: Filtration efficiency for airborne microbial and inert particles, Am. Ind. Hyg. Assoc. J. source
- Not checked — no full text of the sourcecites [27] Li, 2006, In vivo protective performance of N95 respirator and surgical facemask, Am. J. Ind. Med. source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“the efficacy of the single-layer cloth mask is not as clear and complete for the protection and prevention that could be achieved [25-27].”
What the sources say
- Partly supportedcites [25] Asadi, 2020, Efficacy of masks and face coverings in controlling outward aerosol particle emission from expiratory activities, Sci. Rep. sourceExperimental — accuracy not yet measured
The Conclusions (page unavailable) say the efficacy of cloth masks is unclear because of fiber shedding, although they likely reduce some emitted expiratory particles. The Methods identify a single-layer cotton mask, and the Results report increased measured particle emissions while it was worn. The study did not directly measure virus emission or infection, so it does not establish the mask’s effectiveness for protection or prevention. (LLM, conf=0.84)
- Not checked — no full text of the sourcecites [26] Qian, 1998, Performance of N95 respirators: Filtration efficiency for airborne microbial and inert particles, Am. Ind. Hyg. Assoc. J. source
- Not checked — no full text of the sourcecites [27] Li, 2006, In vivo protective performance of N95 respirator and surgical facemask, Am. J. Ind. Med. source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The strongest variable contribution to the formation of the main components was achieved with the variable of S. chromogenes (0.45) but only in the formation of main component p3.”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
47 more claims
Create a free account to see all 104 claims and to verify the 7 references still open.
- Probably not a substantial claim. 27
- It may state two separate claims as one. 30
- The quote only partly states this claim. 2
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ (b) Surgical mask · p. 13
“It should be noted that yeasts and Bacillus spp. were completely filtered by the applied FFP2 and surgical masks.”
§ 3. Results and Discussion · p. 6
“| Bacillus spp. | 15.33 ( ± 1.15) | 11.00 A ( ± 1.00) | 1.33 A,a ( ± 0.58) | 2.33 A,a ( ± 0.58) | 6.67 ( ± 0.58) | 2.00 A ( ± 0.00) | 0.00 A,a ( ± 0.00) | 0.00 A,a ( ± 0.00) |”
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ 3. Results and Discussion · p. 8
“the highest at location D (70% for both bacteria).”
§ 3. Results and Discussion · p. 7
“the single-layer cloth mask showed a very poor filtering efficiency of M. luteus especially at locations A (6%) and D (20%)”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ 3. Results and Discussion · p. 5
“The number of total aerobic mesophilic bacterial colonies grown on TSA and chromogenic agar from analyzed locations A, B, C, and D after air filtration with the single-layer cloth, surgical, and FFP2 masks is presented in Figure 2a,b.”
§ 3. Results and Discussion · p. 5
“Figure 2. Number of grown colonies of ( a ) aerobic mesophilic bacteria on tryptic soy agar (TSA) and ( b ) yeasts and molds on Sabouraud agar (SA)”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ (b) Surgical mask · p. 10
“S. lentus from 15 (location A) to 100% (B)”
§ 3. Results and Discussion · p. 6
“| Staphylococcus lentus | 8.67 ( ± 0.58) | 7.33 ( ± 1.15) | 0.00 A,a ( ± 0.00) | 0.00 A,a ( ± 0.00) | - | - | - | - |”
Citations
Cites
Eikenberry, S. E., Mancuso, M., Iboi, E., Phan, T., Eikenberry, K., Kuang, Y., Kostelich, E., & Gumel, A. B. (2020) · Infectious Disease Modelling · doi:10.1016/j.idm.2020.04.001 · Cited by 1,343
Aerosol filtration efficiency of common fabrics used in respiratory cloth masks
Konda, A., Prakash, A., Moss, G. A., Schmoldt, M., Grant, G. D., & Guha, S. (2020) · ACS Nano · doi:10.1021/acsnano.0c03252 · Cited by 934
Antimicrobial effect of surgical masks coated with nanoparticles
Li, Y., Leung, P., Yao, L., Song, Q. W., & Newton, E. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2005.04.015 · Cited by 572
Testing the Efficacy of Homemade Masks: Would They Protect in an Influenza Pandemic?
Davies, A., Thompson, K.-A., Giri, K., Kafatos, G., Walker, J., & Bennett, A. (2013) · Disaster Medicine and Public Health Preparedness · doi:10.1017/dmp.2013.43 · Cited by 498
Asadi, S., Cappa, C. D., Barreda, S., Wexler, A. S., Bouvier, N. M., & Ristenpart, W. D. (2020) · Scientific Reports · doi:10.1038/s41598-020-72798-7 · Cited by 480
A cluster randomised trial of cloth masks compared with medical masks in healthcare workers
MacIntyre, C. R., Seale, H., Dung, T. C., Hien, N. T., Nga, P. T., Chughtai, A. A., Rahman, B., Dwyer, D. E., & Wang, Q. (2015) · BMJ Open · doi:10.1136/bmjopen-2014-006577 · Cited by 471
An overview of filtration efficiency through the masks: Mechanisms of the aerosols penetration
Tcharkhtchi, A., Abbasnezhad, N., Zarbini Seydani, M., Zirak, N., Farzaneh, S., & Shirinbayan, M. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.08.002 · Cited by 395
Grinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T., McKay, R. T., & Lee, S.-A. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903120086 · Cited by 353
(2010) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meq044 · Cited by 352
Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles
Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891010389 · Cited by 298
Cited by
Assessment of Physical and Mechanical Parameters of Spun-Bond Nonwoven Fabric
Ļašenko, I., Sanchaniya, J. V., Kanukuntla, S.-P., Viļuma-Gudmona, A., Vasilevska, S., & Vejanand, S. R. (2024) · Polymers · doi:10.3390/polym16202920 · Cited by 8
“The assessment of a fabric’s physical and mechanical parameters is crucial for selecting materials suitable for technical applications, particularly for producing personal protective equipment like face masks [9–11].”
BackgroundDenpetkul, T., Srathongneam, T., Sittipunsakda, O., Tancharoen, S., Krabkran, P., Mongkolsuk, S., & Sirikanchana, K. (2025) · Environmental Pollution · doi:10.1016/j.envpol.2025.126180 · Cited by 9
Thite, A. G., Kale, R. D., & Panda, P. K. (2024) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2024.132221 · Cited by 5
Filtering facepiece respirator use among farm youth in the US: A review
Gibbs, J. L., Vollmer, B., Sheridan, C., Pinkerton, K. E., Anthony, R. T., Holm, S. M., Karr, C. J., Proctor, A., & Swenson, A. V. R. (2026) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2025.2589137
“Non-JOURNAL woven materials, common in FFRs, generally exhibited higher filtration efficiencies than woven materials (Lin � sak et al. 2023; Seo et al. 2023).”
1435 Protective garments for food processing workers
Wang, Y., Liu, H., & Wang, X. (2026) · De Gruyter eBooks · doi:10.1515/9783111243757-005
Metadata
- Authors
- Linšak, Ž., Ražov, L., Furlan, N., Begić, G., Pavičić Žeželj, S., Crvelin, G., Broznić, D., & Tomić Linšak, D.
- Affiliations
- University of Rijeka (HR)
- Department of Environmental Health, Teaching Institute of Public Health of Primorje—Gorski Kotar County, Krešimirova 52a, 51000 Rijeka, Croatia
- Department of Environmental Health, Faculty of Medicine, University of Rijeka, Braće Branchetta 20, 51000 Rijeka, Croatia
- Corresponding author
- Broznić, Dalibor
- Venue
- Applied Sciences
- Publisher
- MDPI AG
- Published
- 2023-05-12
- Volume
- 13
- Issue
- 10
- Pages
- 5972
- ISSN
- 2076-3417 (ISSN-L)
- OpenAlex
- W4376274655
- Cited by
- 5
- References
- 26
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2
- FWCI
- 0.92
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Applied Sciences (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- University of Rijeka (Uniri-biomed-18-155-1304)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Keywords
- bacterial filtration efficiency, cloth masks, surgical masks, FFP2 masks, Staphylococcus, Micrococcus, molds and yeasts, COVID-19 prevention, children's schools, mask effectiveness
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-12, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-12 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bacteria Filtration Efficiency for Different Types of Protective Face Masks. https://app.cochat.ai/papers/10.3390/app13105972
- The paper
- Linšak, Ž., Ražov, L., Furlan, N., Begić, G., Pavičić Žeželj, S., Crvelin, G., Broznić, D., & Tomić Linšak, D. (2023). Bacteria Filtration Efficiency for Different Types of Protective Face Masks. Applied Sciences. https://doi.org/10.3390/app13105972
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.