Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 327

The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.

A Comparative Study of PSO-ANN, GA-ANN, ICA-ANN, and ABC-ANN in Estimating the Heating Load of Buildings’ Energy Efficiency for Smart City Planning

Open access
Le, Le Thi, Nguyen, Hoang, Dou, Jie, Zhou, Jian·2019·Applied Sciences

Abstract

Energy-efficiency is one of the critical issues in smart cities. It is an essential basis for optimizing smart cities planning. This study proposed four new artificial intelligence (AI) techniques for forecasting the heating load of buildings’ energy efficiency based on the potential of artificial neural network (ANN) and meta-heuristics algorithms, including artificial bee colony (ABC) optimization, particle swarm optimization (PSO), imperialist competitive algorithm (ICA), and genetic algorithm (GA). They were abbreviated as ABC-ANN, PSO-ANN, ICA-ANN, and GA-ANN models; 837 buildings were considered and analyzed based on the influential parameters, such as glazing area distribution (GLAD), glazing area (GLA), orientation (O), overall height (OH), roof area (RA), wall area (WA), surface area (SA), relative compactness (RC), for estimating heating load (HL). Three statistical criteria, such as root-mean-squared error (RMSE), coefficient determination (R2), and mean absolute error (MAE), were used to assess the potential of the aforementioned models. The results indicated that the GA-ANN model provided the highest performance in estimating the heating load of buildings’ energy efficiency, with an RMSE of 1.625, R2 of 0.980, and MAE of 0.798. The remaining models (i.e., PSO-ANN, ICA-ANN, ABC-ANN) yielded lower performance with RMSE of 1.932, 1.982, 1.878; R2 of 0.972, 0.970, 0.973; MAE of 1.027, 0.980, 0.957, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/app9132630

Cites

55 of 55 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 55 references

Cited by

See all 327

Metadata

Authors
Le, L. T., Nguyen, H., Dou, J., & Zhou, J.
Venue
Applied Sciences
Publisher
MDPI AG
Published
2019-06-28
Volume
9
Issue
13
Pages
2630
ISSN
2076-3417 (ISSN-L)
OpenAlex
W2954464033
Cited by
327
References
55
FWCI
28.76
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparative Study of PSO-ANN, GA-ANN, ICA-ANN, and ABC-ANN in Estimating the Heating Load of Buildings’ Energy Efficiency for Smart City Planning. https://app.cochat.ai/papers/10.3390/app9132630
The paper
Le, L. T., Nguyen, H., Dou, J., & Zhou, J. (2019). A Comparative Study of PSO-ANN, GA-ANN, ICA-ANN, and ABC-ANN in Estimating the Heating Load of Buildings’ Energy Efficiency for Smart City Planning. Applied Sciences. https://doi.org/10.3390/app9132630

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.