CoChat

Discontinuities in the Ozone Concentration Time Series from MERRA 2 Reanalysis

Open access
Krizan, Peter, Kozubek, Michal, Lastovicka, Jan · 2019 · Atmosphere

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

Artificial discontinuities in time series are a great problem for trend analysis because they influence the values of the trend and its significance. The aim of this paper is to investigate their occurrence in the Modern-Era Retrospective analysis for Research and Applications, version 2 (MERRA 2) ozone concentration data. It is the first step toward the utilization of the MERRA 2 ozone data for trend analysis. We use the Pettitt homogeneity test to search for discontinuities in the ozone time series. We showed the data above 4 hPa are not suitable for trend analyses due to the unrealistic patterns in an average ozone concentration and due to the frequent occurrence of significant discontinuities. Below this layer in the stratosphere, their number is much smaller, and mostly, they are insignificant, and the patterns of the average ozone concentration are explainable. In the troposphere, the number of discontinuities increases, but they are insignificant. The transition from Solar Backscatter Ultraviolet Radiometer (SBUV) to Earth Observing System (EOS) Aura data in 2004 is visible only above 1 hPa, where the data are not suitable for trend analyses due to other reasons. We can conclude the MERRA 2 ozone concentration data can be used in trend analysis with caution only below 4 hPa.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/atmos10120812

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Average ozone concentration (kg/kg) in January at 0.1 hPa ( upper panel ) and at 0.5 hPa Figure 1. Average ozone concentration (kg / kg) in January at 0.1 hPa ( upper panel ) and at 0.5 hPa ( lower panel ). Figure 1. Average ozone concentration (kg/kg) in January at 0.1 hPa ( upper panel ) and at 0.5 hPa ( lower panel ).
Figure 1 Average ozone concentration (kg/kg) in January at 0.1 hPa ( upper panel ) and at 0.5 hPa Figure 1. Average ozone concentration (kg / kg) in January at 0.1 hPa ( upper panel ) and at 0.5 hPa ( lower panel ). Figure 1. Average ozone concentration (kg/kg) in January at 0.1 hPa ( upper panel ) and at 0.5 hPa ( lower panel ).CC-BY · From the PDF
Figure 2 The same as Figure 1, but for January at 1 hPa ( upper panel ) and for July at 1 hPa ( lower panel ). Atmosphere 2018 , 9 , x FOR PEER REVIEW
Figure 2 The same as Figure 1, but for January at 1 hPa ( upper panel ) and for July at 1 hPa ( lower panel ). Atmosphere 2018 , 9 , x FOR PEER REVIEWCC-BY · From the PDF
Figure 3 Average ozone concentration (kg/kg) in January at 10 hPa ( upper panel ) and at 50 hPa ( lower Figure 3. Average ozone concentration (kg / kg) in January at 10 hPa ( upper panel ) and at 50 hPa ( lower panel ).
Figure 3 Average ozone concentration (kg/kg) in January at 10 hPa ( upper panel ) and at 50 hPa ( lower Figure 3. Average ozone concentration (kg / kg) in January at 10 hPa ( upper panel ) and at 50 hPa ( lower panel ).CC-BY · From the PDF
Figure 4 Average ozone concentration (kg/kg) in January at 300 hPa ( upper panel ) and at 500 hPa Figure 4. Average ozone concentration (kg / kg) in January at 300 hPa ( upper panel ) and at 500 hPa ( lower panel ).
Figure 4 Average ozone concentration (kg/kg) in January at 300 hPa ( upper panel ) and at 500 hPa Figure 4. Average ozone concentration (kg / kg) in January at 300 hPa ( upper panel ) and at 500 hPa ( lower panel ).CC-BY · From the PDF
Image 5
CC-BY · From the PDF
Image 6
CC-BY · From the PDF
Image 7
CC-BY · From the PDF
Image 8
CC-BY · From the PDF
Figure 9 Vertical profiles of percentage occurrence of all ( upper panel ) and significant discontinuities ( lower panel ) in all months. Figure 9. Vertical profiles of percentage occurrence of all ( upper panel ) and significant discontinuities ( lower panel ) in all months.
Figure 9 Vertical profiles of percentage occurrence of all ( upper panel ) and significant discontinuities ( lower panel ) in all months. Figure 9. Vertical profiles of percentage occurrence of all ( upper panel ) and significant discontinuities ( lower panel ) in all months.CC-BY · From the PDF
Image 10
CC-BY · From the PDF
Figure 11 The same as Figure 10, but for 3 hPa.
Figure 11 The same as Figure 10, but for 3 hPa.CC-BY · From the PDF
Image 12
CC-BY · From the PDF
Figure 13 The same as Figure 12, but for 250 hPa.
Figure 13 The same as Figure 12, but for 250 hPa.CC-BY · From the PDF
Image 14
CC-BY · From the PDF
Image 15
CC-BY · From the PDF
Figure 16 The same as Figure 15, but for 0.4 hPa.
Figure 16 The same as Figure 15, but for 0.4 hPa.CC-BY · From the PDF
Image 17
CC-BY · From the PDF
Figure 19 Geographical distribution of all (upper panel) and the significant (lower panel) Figure 19. Geographical distribution of all ( upper panel ) and the significant ( lower panel ) discontinuities over the globe at 30 hPa.
Figure 19 Geographical distribution of all (upper panel) and the significant (lower panel) Figure 19. Geographical distribution of all ( upper panel ) and the significant ( lower panel ) discontinuities over the globe at 30 hPa.CC-BY · From the PDF
Figure 20 The same as Figure 19, but for 300 hPa. Figure 20. The same as Figure 19, but for 300 hPa.
Figure 20 The same as Figure 19, but for 300 hPa. Figure 20. The same as Figure 19, but for 300 hPa.CC-BY · From the PDF
Figure 21 Geographical distribution of all ( upper panel ) and the significant ( lower panel ) Figure 21. Geographical distribution of all ( upper panel ) and the significant ( lower panel ) discontinuities over the globe at 500 hPa.
Figure 21 Geographical distribution of all ( upper panel ) and the significant ( lower panel ) Figure 21. Geographical distribution of all ( upper panel ) and the significant ( lower panel ) discontinuities over the globe at 500 hPa.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 9

Metadata

Authors
Krizan, P., Kozubek, M., & Lastovicka, J.
Affiliations
  • Institute of Atmospheric Physics, Czech Academy of Sciences, 14100 Prague, Czech Republic
  • Czech Academy of Sciences (CZ)
Venue
Atmosphere
Publisher
MDPI AG
Published
2019-12-14
Volume
10
Issue
12
Pages
812
ISSN
2073-4433 (ISSN-L)
OpenAlex
W2995138128
Cited by
9
References
29
Citations by year
2026: 1 · 2025: 1 · 2023: 1 · 2021: 1 · 2020: 5
FWCI
0.59
Type
journal article
Language
en
Open access
Locations
Atmosphere (publishedVersion, cc-by)
Funders
Grantová Agentura České Republiky (18-01625S)
Topics
  • Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric Ozone and Climate
  • Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
  • Physical Sciences › Environmental Science › Global and Planetary Change › Atmospheric aerosols and clouds
Keywords
ozone concentration, MERRA-2, time series homogeneity, Pettitt test, stratosphere, troposphere, data quality

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.