A Microfluidic System for the Investigation of Tumor Cell Extravasation
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Metastatic dissemination of cancer cells is a very complex process. It includes the intravasation of cells into the metastatic pathways, their passive distribution within the blood or lymph flow, and their extravasation into the surrounding tissue. Crucial steps during extravasation are the adhesion of the tumor cells to the endothelium and their transendothelial migration. However, the molecular mechanisms that are underlying this process are still not fully understood. Novel three dimensional (3D) models for research on the metastatic cascade include the use of microfluidic devices. Different from two dimensional (2D) models, these devices take cell–cell, structural, and mechanical interactions into account. Here we introduce a new microfluidic device in order to study tumor extravasation. The device consists of three different parts, containing two microfluidic channels and a porous membrane sandwiched in between them. A smaller channel together with the membrane represents the vessel equivalent and is seeded separately with primary endothelial cells (EC) that are isolated from the lung artery. The second channel acts as reservoir to collect the migrated tumor cells. In contrast to many other systems, this device does not need an additional coating to allow EC growth, as the primary EC that is used produces their own basement membrane. VE-Cadherin, an endothelial adherence junction protein, was expressed in regular localization, which indicates a tight barrier function and cell–cell connections of the endothelium. The EC in the device showed in vivo-like behavior under flow conditions. The GFP-transfected tumor cells that were introduced were of epithelial or mesenchymal origin and could be observed by live cell imaging, which indicates tightly adherent tumor cells to the endothelial lining under different flow conditions. These results suggest that the new device can be used for research on molecular requirements, conditions, and mechanism of extravasation and its inhibition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrigel: A complex protein mixture required for optimal growth of cell culture
Hughes, C. S., Postovit, L. M., & Lajoie, G. A. (2010) · PROTEOMICS · doi:10.1002/pmic.200900758 · Cited by 1,534 · cited 1×
“Specifically, collagen I and matrigel, which were frequently used in the microfluidic systems, were not regular components of the vascular basement membrane and could show the batch to batch variability and could therefore be a source of variable experimental results [43,47].”
Result3D Cell Culture Systems: Advantages and Applications
Ravi, M., Paramesh, V., Kaviya, S. R., Anuradha, E., & Solomon, F. D. P. (2015) · Journal of Cellular Physiology · doi:10.1002/jcp.24683 · Cited by 1,206
Crossing the endothelial barrier during metastasis
Reymond, N., d'Água, B. B., & Ridley, A. J. (2013) · Nature Reviews Cancer · doi:10.1038/nrc3628 · Cited by 922 · cited 1×
“Using this type of microfluidic system, the transendothelial migration, an essential step in successful metastasis of tumor cells, could be investigated under in vivo-like conditions [48].”
MethodThree-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872 · cited 1×
“In this model, the tumor cells migrate towards the endothelial cells and intravasate without adding any kind of flow [35].”
Human 3D vascularized organotypic microfluidic assays to study breast cancer cell extravasation
Jeon, J. S., Bersini, S., Gilardi, M., Dubini, G., Charest, J. L., Moretti, M., & Kamm, R. D. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1417115112 · Cited by 723
Three-dimensional tissue culture models in cancer biology
Kim, J. B. (2005) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2005.05.002 · Cited by 613
A microfluidic 3D in vitro model for specificity of breast cancer metastasis to bone
Bersini, S., Jeon, J. S., Dubini, G., Arrigoni, C., Chung, S., Charest, J. L., Moretti, M., & Kamm, R. D. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.050 · Cited by 534 · cited 11×
“Independent of the model geometry or of the type of endothelial cells that are used, most of these devices are made of Polydimethylsiloxane (PDMS), which is frequently activated by plasma-treatment and is bonded to glass [17,31,33,34].”
BackgroundMethodResultInfluentialMicrofluidic 3D cell culture: from tools to tissue models
van Duinen, V., Trietsch, S. J., Joore, J., Vulto, P., & Hankemeier, T. (2015) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2015.05.002 · Cited by 500
Microfluidic Endothelium for Studying the Intravascular Adhesion of Metastatic Breast Cancer Cells
Song, J. W., Cavnar, S. P., Walker, A. C., Luker, K. E., Gupta, M., Tung, Y.-C., Luker, G. D., & Takayama, S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005756 · Cited by 317
Mechanisms of tumor cell extravasation in an in vitro microvascular network platform
Chen, M. B., Whisler, J. A., Jeon, J. S., & Kamm, R. D. (2013) · Integrative Biology · doi:10.1039/c3ib40149a · Cited by 308
Cited by
Surface Modification Techniques for Endothelial Cell Seeding in PDMS Microfluidic Devices
Akther, F., Yakob, S. B., Nguyen, N.-T., & Ta, H. T. (2020) · Biosensors · doi:10.3390/bios10110182 · Cited by 182
Cell Culture Based in vitro Test Systems for Anticancer Drug Screening
Kitaeva, K. V., Rutland, C. S., Rizvanov, A. A., & Solovyeva, V. V. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00322 · Cited by 142
Etezadi, F., Le, M. N. T., Shahsavarani, H., Alipour, A., Moazzezy, N., Samani, S., Amanzadeh, A., Pahlavan, S., Bonakdar, S., Shokrgozar, M. A., et al. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c00162 · Cited by 33
Developing Liver Microphysiological Systems for Biomedical Applications
Wang, J., Wu, X., Zhao, J., Ren, H., & Zhao, Y. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202302217 · Cited by 27
Metadata
- Authors
- Kühlbach, C., Da Luz, S., Baganz, F., Hass, V. C., & Mueller, M. M.
- Venue
- Bioengineering
- Publisher
- MDPI AG
- Published
- 2018-05-23
- Volume
- 5
- Issue
- 2
- Pages
- 40
- ISSN
- 2306-5354 (ISSN-L)
- OpenAlex
- W2804200217
- Cited by
- 38
- References
- 16
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Microfluidic System for the Investigation of Tumor Cell Extravasation. https://app.cochat.ai/papers/10.3390/bioengineering5020040
- The paper
- Kühlbach, C., Da Luz, S., Baganz, F., Hass, V. C., & Mueller, M. M. (2018). A Microfluidic System for the Investigation of Tumor Cell Extravasation. Bioengineering. https://doi.org/10.3390/bioengineering5020040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.